On-line localization of the lumpectomy cavity using surgical clips.

Leonard H Kim1, John Wong, Di Yan.   

Abstract

PURPOSE: To present an on-line image guidance procedure for external beam accelerated partial breast irradiation based on cone-beam computed tomography (CBCT) imaging of surgical clips; and to estimate the possible clinical target volume (CTV) to planning target volume (PTV) margin reduction allowed by this technique. METHODS AND MATERIALS: Clips in the CBCT image are detected automatically using in-house software. The treatment couch is translated according to the shift in the clips' center of mass between the planning and CBCT images. Three components for the PTV margin are considered: (1) breathing, (2) surrogate error (i.e., error in cavity position after perfect setup to clips), and (3) residual error (i.e., error arising from the inability to execute a perfect setup to clips due to technological limitations, such as couch travel precision). These factors were input into a standard formula for CTV-to-PTV margin calculation.
RESULTS: The average magnitude of clip-based corrections was 7 +/- 2 mm (10 patients, 44 fractions). After localization, the residual error magnitude was 1.6 +/- 1.3 mm, justifying an isotropic CTV-to-PTV margin of approximately 6 mm, including breathing and surrogate error.
CONCLUSIONS: On-line localization of the lumpectomy cavity using surgical clips is technically feasible from the standpoint of equipment, time, and process, making possible a decreased CTV-to-PTV margin for accelerated partial breast irradiation. Because the procedure is exclusively target based, additional monitoring of critical structures may be advisable.

Entities:  

Mesh:

Year:  2007        PMID: 17967320     DOI: 10.1016/j.ijrobp.2007.07.2365

Source DB:  PubMed          Journal:  Int J Radiat Oncol Biol Phys        ISSN: 0360-3016            Impact factor:   7.038


  7 in total

1.  Dosimetric feasibility of an "off-breast isocenter" technique for whole-breast cancer radiotherapy.

Authors:  Juan-Francisco Calvo-Ortega; Sandra Moragues; Miquel Pozo; Joan Casals
Journal:  Rep Pract Oncol Radiother       Date:  2016-08-24

2.  Set-up uncertainty during breast radiotherapy. Image-guided radiotherapy for patients with initial extensive variation.

Authors:  D S Yang; W S Yoon; S Y Chung; J A Lee; S Lee; Y J Park; C Y Kim; G S Son
Journal:  Strahlenther Onkol       Date:  2013-02-28       Impact factor: 3.621

3.  An image-guided study of setup reproducibility of postmastectomy breast cancer patients treated with inverse-planned intensity modulated radiation therapy.

Authors:  Christine H Feng; Emily Gerry; Steven J Chmura; Yasmin Hasan; Hania A Al-Hallaq
Journal:  Int J Radiat Oncol Biol Phys       Date:  2014-10-22       Impact factor: 7.038

4.  Optimization of Adjuvant Radiation in Breast Conservation Therapy: Can We Minimize without Compromise?

Authors:  Sophia M Edwards-Bennett; Candace R Correa; Eleanor E Harris
Journal:  Int J Breast Cancer       Date:  2011-10-05

5.  Comparison of setup accuracy of three different image assessment methods for tangential breast radiotherapy.

Authors:  Vikneswary Batumalai; Penny Phan; Callie Choong; Lois Holloway; Geoff P Delaney
Journal:  J Med Radiat Sci       Date:  2016-05-31

6.  Optimal parameters for clinical implementation of breast cancer patient setup using Varian DTS software.

Authors:  Sook Kien Ng; Piotr Zygmanski; Andrew Jeung; Hassan Mostafavi; Juergen Hesser; Jennifer R Bellon; Julia S Wong; Yulia Lyatskaya
Journal:  J Appl Clin Med Phys       Date:  2012-05-10       Impact factor: 2.102

7.  Comprehensive target geometric errors and margin assessment in stereotactic partial breast irradiation.

Authors:  Xin Zhen; Bo Zhao; Zhuoyu Wang; Robert Timmerman; Ann Spangler; Nathan Kim; Asal Rahimi; Xuejun Gu
Journal:  Radiat Oncol       Date:  2017-09-11       Impact factor: 3.481

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.