Literature DB >> 22553296

Clinical implementation of kilovoltage cone beam CT for the verification of sequential and integrated photon boost treatments for breast cancer patients.

E M Donovan1, I Castellano, S Eagle, E Harris.   

Abstract

OBJECTIVE: The objective of this study was to formulate a practical method for the use of cone beam CT (CBCT) for the verification of sequential and integrated tumour bed boosts for early breast cancer patients.
METHODS: Partial arc scan geometries were assessed on a treatment unit. Imaging dose measurements on an Elekta Synergy CBCT system were made in a CT dose phantom for scan parameters 100 kV, 25 mA and 40 ms with an S20 collimator. The protocol was used to verify the setup of a cohort of 38 patients, all of whom had surgical clips inserted in the tumour bed. Setup errors with and without an extended no action level (eNAL) protocol were calculated.
RESULTS: Arcs from 260° to 85° (left breast) and 185° to 15° (right breast) were found sufficient to image fiducial markers and anatomy whilst accounting for the physical limits of the equipment. A single treatment and imaging isocentre was found by applying simple constraints: isocentre <8 cm from midline and isocentre-couch distance <30 cm. Contralateral breast doses were ∼2 mGy per scan (right breast) and ∼12 mGy (left breast). Both mean population systematic error and mean population random error were 3 mm prior to correction. The systematic error reduced to 1.5 mm using an eNAL correction protocol, implying that a 5-mm setup margin could be achieved.
CONCLUSION: An image-guided verification protocol using CBCT for breast cancer boost plans was implemented successfully. Setup errors were reduced with an acceptable imaging dose to the contralateral breast.

Entities:  

Mesh:

Year:  2012        PMID: 22553296      PMCID: PMC3477491          DOI: 10.1259/bjr/28845176

Source DB:  PubMed          Journal:  Br J Radiol        ISSN: 0007-1285            Impact factor:   3.039


  13 in total

1.  Inclusion of geometrical uncertainties in radiotherapy treatment planning by means of coverage probability.

Authors:  J C Stroom; H C de Boer; H Huizenga; A G Visser
Journal:  Int J Radiat Oncol Biol Phys       Date:  1999-03-01       Impact factor: 7.038

2.  Clinical application of varian OBI CBCT system and dose reduction techniques in breast cancer patients setup.

Authors:  Stefan Ueltzhöffer; Piotr Zygmanski; Jürgen Hesser; Wolfgang Högele; Julia Wong; Jennifer R Bellon; Yulia Lyatskaya
Journal:  Med Phys       Date:  2010-06       Impact factor: 4.071

3.  Planning with intensity-modulated radiotherapy and tomotherapy to modulate dose across breast to reflect recurrence risk (IMPORT High trial).

Authors:  Ellen M Donovan; Laura Ciurlionis; Jamie Fairfoul; Hayley James; Helen Mayles; Sophie Manktelow; Sanjay Raj; Yat Tsang; Nicola Tywman; John Yarnold; Charlotte Coles
Journal:  Int J Radiat Oncol Biol Phys       Date:  2010-06-03       Impact factor: 7.038

4.  The IMPORT trials are launched (September 2006).

Authors:  C Coles; J Yarnold
Journal:  Clin Oncol (R Coll Radiol)       Date:  2006-10       Impact factor: 4.126

5.  The 2007 Recommendations of the International Commission on Radiological Protection. ICRP publication 103.

Authors: 
Journal:  Ann ICRP       Date:  2007

6.  Doses to critical organs following radiotherapy and concomitant imaging of the larynx and breast.

Authors:  R M Harrison; M Wilkinson; D J Rawlings; M Moore
Journal:  Br J Radiol       Date:  2007-12       Impact factor: 3.039

7.  eNAL: an extension of the NAL setup correction protocol for effective use of weekly follow-up measurements.

Authors:  Hans C J de Boer; Ben J M Heijmen
Journal:  Int J Radiat Oncol Biol Phys       Date:  2007-04-01       Impact factor: 7.038

8.  Doses to organs and tissues from concomitant imaging in radiotherapy: a suggested framework for clinical justification.

Authors:  R M Harrison
Journal:  Br J Radiol       Date:  2008-10-13       Impact factor: 3.039

9.  Radiation therapy using a simultaneously integrated boost for early-stage breast cancer.

Authors:  Coen Hurkmans
Journal:  Future Oncol       Date:  2007-10       Impact factor: 3.404

10.  A protocol for the reduction of systematic patient setup errors with minimal portal imaging workload.

Authors:  H C de Boer; B J Heijmen
Journal:  Int J Radiat Oncol Biol Phys       Date:  2001-08-01       Impact factor: 7.038

View more
  9 in total

1.  Dosimetric feasibility of an "off-breast isocenter" technique for whole-breast cancer radiotherapy.

Authors:  Juan-Francisco Calvo-Ortega; Sandra Moragues; Miquel Pozo; Joan Casals
Journal:  Rep Pract Oncol Radiother       Date:  2016-08-24

2.  Setup accuracy for prone and supine whole breast irradiation.

Authors:  Thomas Mulliez; Akos Gulyban; Tom Vercauteren; Annick van Greveling; Bruno Speleers; Wilfried De Neve; Liv Veldeman
Journal:  Strahlenther Onkol       Date:  2016-02-10       Impact factor: 3.621

3.  Comparison of different registration methods and landmarks for image-guided radiation therapy of pulmonary tumors.

Authors:  Xiaohui Cao; Ming Liu; Fushan Zhai; Nan Li; Chaoen Bao; Yinliang Liu; Gang Chen
Journal:  BMC Med Imaging       Date:  2019-05-31       Impact factor: 1.930

Review 4.  Target motion management in breast cancer radiation therapy.

Authors:  Elham Piruzan; Naser Vosoughi; Seied Rabi Mahdavi; Leila Khalafi; Hojjat Mahani
Journal:  Radiol Oncol       Date:  2021-10-08       Impact factor: 2.991

5.  Second cancer incidence risk estimates using BEIR VII models for standard and complex external beam radiotherapy for early breast cancer.

Authors:  E M Donovan; H James; M Bonora; J R Yarnold; P M Evans
Journal:  Med Phys       Date:  2012-10       Impact factor: 4.071

6.  Mean heart dose variation over a course of breath-holding breast cancer radiotherapy.

Authors:  Nicolle Dunkerley; Frederick R Bartlett; Anna M Kirby; Philip M Evans; Ellen M Donovan
Journal:  Br J Radiol       Date:  2016-09-20       Impact factor: 3.039

7.  Optical Surface Management System for Patient Positioning in Interfractional Breast Cancer Radiotherapy.

Authors:  Zhao Ma; Wei Zhang; Yi Su; Peiji Liu; Yinghua Pan; Gang Zhang; Yipeng Song
Journal:  Biomed Res Int       Date:  2018-01-09       Impact factor: 3.411

8.  Crawl positioning improves set-up precision and patient comfort in prone whole breast irradiation.

Authors:  Pieter Deseyne; Bruno Speleers; Wilfried De Neve; Bert Boute; Leen Paelinck; Vincent Vakaet; Hans Van Hulle; Max Schoepen; Michael Stouthandel; Annick Van Greveling; Giselle Post; Jan Detand; Chris Monten; Herman Depypere; Liv Veldeman
Journal:  Sci Rep       Date:  2020-10-02       Impact factor: 4.379

9.  Does the protocol-required uniform margin around the CTV adequately account for setup inaccuracies in whole breast irradiation?

Authors:  Jurui Luo; Zhihai Yin; Zhen Zhang; Xiaomao Guo; Xiaoli Yu; Juanqi Wang
Journal:  Radiat Oncol       Date:  2021-08-03       Impact factor: 3.481

  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.