Literature DB >> 18973853

Early clinical experience with kilovoltage image-guided radiation therapy for interfraction motion management.

Joshua D Lawson1, Tim Fox, Eric Elder, Adam Nowlan, Lawrence Davis, James Keller, Ian Crocker.   

Abstract

Interest in image-guided radiation therapy (IGRT) reflects the desire to minimize interfraction positioning variability. Using a kilovoltage (kV) imaging unit mounted to a traditional LINAC allows daily matching of kV images to planning digitally reconstructed radiographs (DRRs). We quantify and evaluate the significance of calculated deviation from the intended isocenter. Since September 2004, 117 patients with various malignancies were treated using the On-Board Imaging (OBI) system, with 2088 treatment sessions. Patients were positioned by the treating therapist; orthogonal images were then obtained with the OBI unit. Couch shifts were made, aligning bony anatomy to the initial simulation image. Routine port films were performed weekly (after that day's OBI session). Ninety percent of all lateral, longitudinal, and vertical shifts were less than 0.8 cm, 0.6 cm, and 0.7 cm, respectively. The median vector shift for each anatomic site was: 0.42 cm for head and neck, 0.40 cm for CNS, 0.59 cm for GU/prostate, and 0.73 cm for breast; shift magnitude did not change with successive OBI sessions. The use of OBI effectively corrects setup variability. These shifts are typically small and random. The use of OBI likely can replace weekly port films for isocenter verification; however, OBI does not provide field shape verification.

Entities:  

Mesh:

Year:  2008        PMID: 18973853     DOI: 10.1016/j.meddos.2007.06.002

Source DB:  PubMed          Journal:  Med Dosim        ISSN: 1873-4022            Impact factor:   1.482


  6 in total

1.  Dosimetric feasibility of an "off-breast isocenter" technique for whole-breast cancer radiotherapy.

Authors:  Juan-Francisco Calvo-Ortega; Sandra Moragues; Miquel Pozo; Joan Casals
Journal:  Rep Pract Oncol Radiother       Date:  2016-08-24

Review 2.  Exciting new advances in neuro-oncology: the avenue to a cure for malignant glioma.

Authors:  Erwin G Van Meir; Costas G Hadjipanayis; Andrew D Norden; Hui-Kuo Shu; Patrick Y Wen; Jeffrey J Olson
Journal:  CA Cancer J Clin       Date:  2010 May-Jun       Impact factor: 508.702

3.  Daily patient setup error in prostate image guided radiation therapy with fiducial-based kilovoltage onboard imaging and conebeam computed tomography.

Authors:  Jason C Ye; Muhammad M Qureshi; Pauline Clancy; Lauren N Dise; John Willins; Ariel E Hirsch
Journal:  Quant Imaging Med Surg       Date:  2015-10

4.  Accurate positioning for head and neck cancer patients using 2D and 3D image guidance.

Authors:  Hyejoo Kang; Dale M Lovelock; Ellen D Yorke; Sergey Kriminski; Nancy Lee; Howard I Amols
Journal:  J Appl Clin Med Phys       Date:  2010-10-27       Impact factor: 2.102

5.  Assessment of CT to CBCT contour mapping for radiomic feature analysis in prostate cancer.

Authors:  Ryder M Schmidt; Rodrigo Delgadillo; John C Ford; Kyle R Padgett; Matthew Studenski; Matthew C Abramowitz; Benjamin Spieler; Yihang Xu; Fei Yang; Nesrin Dogan
Journal:  Sci Rep       Date:  2021-11-23       Impact factor: 4.379

6.  Recent advances in image-guided radiotherapy for head and neck carcinoma.

Authors:  Sameer K Nath; Daniel R Simpson; Brent S Rose; Ajay P Sandhu
Journal:  J Oncol       Date:  2009-07-29       Impact factor: 4.375