Literature DB >> 27696628

Reproducibility of high-definition (3D) manometry and its agreement with high-resolution (2D) manometry in women with fecal incontinence.

S Chakraborty1, K J Feuerhak1, A R Zinsmeister2, A E Bharucha1.   

Abstract

BACKGROUND: While widely used in clinical practice, the reproducibility of high-definition anorectal manometry (HD-ARM) remains unclear. We evaluated the intra-individual reproducibility of HD-ARM and compared pressures measured with HD-ARM and high-resolution anorectal manometry (HR-ARM).
METHODS: Thirty-six women with fecal incontinence had an initial HD-ARM (HD-ARM1); on the same day, after randomization, 21 had a second (HD-ARM2). Sixteen women had a third (HD-ARM3) 4 weeks later. Twenty-five had also been evaluated by HR-ARM previously. Rectoanal pressures were assessed at rest, during squeeze and simulated evacuation. Concordance among pressures was assessed with Lin's concordance correlation coefficient (CCC). KEY
RESULTS: Anal resting and squeeze pressures measured with HD-ARM were reproducible on the same and different days; for average resting pressures of HD-ARM1 vs HD-ARM2, CCC = 0.73 (95% confidence interval [CI]: 0.53-0.94), and for HD-ARM1 vs HD-ARM3, CCC = 0.60 (95% CI: 0.28-0.93). For maximum squeeze pressures of HD-ARM1 vs HD-ARM2, CCC = 0.86 (95% CI: 0.75-0.97), and for HD-ARM1 vs HD-ARM3, CCC = 0.56 (95% CI: 0.21-0.91). The rectoanal gradient during evacuation was significantly concordant between HD-ARM1 and HD-ARM2 but not HD-ARM1 and HD-ARM3. Resting (CCC = 0.38 [95% CI: 0.14-0.62]) and squeeze pressures (CCC = 0.73 [95% CI: 0.57-0.89]) measured with HD-ARM1 and HR-ARM were also concordant. CONCLUSIONS & INFERENCES: Among women with fecal incontinence, measurements with HD-ARM were reproducible on the same (anal resting and squeeze pressures and rectoanal gradient during evacuation) and different days (anal resting and squeeze pressures) and correlated with HR-ARM measurements. These findings support use of HD-ARM and HR-ARM for longitudinal assessments of anal resting and squeeze pressures.
© 2016 John Wiley & Sons Ltd.

Entities:  

Keywords:  anorectal; fecal incontinence; high definition; high resolution; manometry; reproducibility

Mesh:

Year:  2016        PMID: 27696628      PMCID: PMC5329128          DOI: 10.1111/nmo.12950

Source DB:  PubMed          Journal:  Neurogastroenterol Motil        ISSN: 1350-1925            Impact factor:   3.598


  25 in total

1.  Estimating the generalized concordance correlation coefficient through variance components.

Authors:  Josep L Carrasco; Lluís Jover
Journal:  Biometrics       Date:  2003-12       Impact factor: 2.571

2.  Functional morphology of anal sphincter complex unveiled by high definition anal manometery and three dimensional ultrasound imaging.

Authors:  V Raizada; V Bhargava; A Karsten; R K Mittal
Journal:  Neurogastroenterol Motil       Date:  2011-09-25       Impact factor: 3.598

3.  Test-retest repeatability of anorectal physiology tests in healthy volunteers.

Authors:  A M Ryhammer; S Laurberg; A P Hermann
Journal:  Dis Colon Rectum       Date:  1997-03       Impact factor: 4.585

4.  Toward more accurate measurements of anorectal motor and sensory function in routine clinical practice: validation of high-resolution anorectal manometry and Rapid Barostat Bag measurements of rectal function.

Authors:  M Sauter; H Heinrich; M Fox; B Misselwitz; M Halama; W Schwizer; M Fried; H Fruehauf
Journal:  Neurogastroenterol Motil       Date:  2014-02-12       Impact factor: 3.598

5.  Anorectal physiology validated: a repeatability study of the motor and sensory tests of anorectal function.

Authors:  J Rogers; S Laurberg; J J Misiewicz; M M Henry; M Swash
Journal:  Br J Surg       Date:  1989-06       Impact factor: 6.939

6.  Phenotypic identification and classification of functional defecatory disorders using high-resolution anorectal manometry.

Authors:  Shiva K Ratuapli; Adil E Bharucha; Jessica Noelting; Doris M Harvey; Alan R Zinsmeister
Journal:  Gastroenterology       Date:  2012-11-07       Impact factor: 22.682

7.  The external anal sphincter operates at short sarcomere length in humans.

Authors:  R K Mittal; G Sheean; B S Padda; R Lieber; M Raj Rajasekaran
Journal:  Neurogastroenterol Motil       Date:  2011-03-21       Impact factor: 3.598

8.  Accuracy and Reproducibility of High-definition Anorectal Manometry and Pressure Topography Analyses in Healthy Subjects.

Authors:  Enrique Coss-Adame; Satish S C Rao; Jessica Valestin; Amyra Ali-Azamar; Jose M Remes-Troche
Journal:  Clin Gastroenterol Hepatol       Date:  2015-01-20       Impact factor: 11.382

9.  Repeatability of anorectal manometry in healthy volunteers and patients.

Authors:  Susanne D Otto; Johanna M Clewing; Jörn Gröne; Heinz J Buhr; Anton J Kroesen
Journal:  J Surg Res       Date:  2013-06-28       Impact factor: 2.192

10.  How to Perform and Interpret a High-resolution Anorectal Manometry Test.

Authors:  Tae Hee Lee; Adil E Bharucha
Journal:  J Neurogastroenterol Motil       Date:  2016-01-31       Impact factor: 4.924

View more
  6 in total

Review 1.  High-resolution anorectal manometry: An expensive hobby or worth every penny?

Authors:  G Basilisco; A E Bharucha
Journal:  Neurogastroenterol Motil       Date:  2017-08       Impact factor: 3.598

Review 2.  Review of the indications, methods, and clinical utility of anorectal manometry and the rectal balloon expulsion test.

Authors:  Adil E Bharucha; Guido Basilisco; Allison Malcolm; Tae Hee Lee; Matthew B Hoy; S Mark Scott; Satish S C Rao
Journal:  Neurogastroenterol Motil       Date:  2022-02-27       Impact factor: 3.960

3.  Tools for fecal incontinence assessment: lessons for inflammatory bowel disease trials based on a systematic review.

Authors:  Ferdinando D'Amico; Steven D Wexner; Carolynne J Vaizey; Célia Gouynou; Silvio Danese; Laurent Peyrin-Biroulet
Journal:  United European Gastroenterol J       Date:  2020-07-17       Impact factor: 4.623

4.  A multicenter study of anorectal pressures and rectal sensation measured with portable manometry in healthy women and men.

Authors:  Mayank Sharma; Ann C Lowry; Satish S Rao; William E Whitehead; Lawrence A Szarka; Frank A Hamilton; Adil E Bharucha
Journal:  Neurogastroenterol Motil       Date:  2021-01-18       Impact factor: 3.960

5.  3D high-resolution anorectal manometry in patients with perianal fistulas: comparison with 3D-anal ultrasound.

Authors:  Richelle J F Felt-Bersma; Maarten S Vlietstra; Paul F Vollebregt; Ingrid J M Han-Geurts; Vera Rempe-Sorm; Grietje J H Vander Mijnsbrugge; Charlotte B H Molenaar
Journal:  BMC Gastroenterol       Date:  2018-04-04       Impact factor: 3.067

Review 6.  Recent advances in understanding and managing chronic constipation.

Authors:  David O Prichard; Adil E Bharucha
Journal:  F1000Res       Date:  2018-10-15
  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.