Literature DB >> 25132471

Systemic toxicity related to metal hip prostheses.

S M Bradberry1, J M Wilkinson, R E Ferner.   

Abstract

INTRODUCTION: One in eight of all total hip replacements requires revision within 10 years, 60% because of wear-related complications. The bearing surfaces may be made of cobalt/chromium, stainless steel, ceramic, or polyethylene. Friction between bearing surfaces and corrosion of non-moving parts can result in increased local and systemic metal concentrations.
OBJECTIVES: To identify and systematically review published reports of systemic toxicity attributed to metal released from hip implants and to propose criteria for the assessment of these patients.
METHODS: Medline (from 1950) and Embase (from 1980) were searched to 28 February 2014 using the search terms (text/abstract) chrom* or cobalt* and [toxic* or intox* or poison* or adverse effect or complication] and [prosthes* or 'joint replacement' or hip or arthroplast*] and PubMed (all available years) was searched using the search term (("Chromium/adverse effects"[Mesh] OR "Chromium/poisoning"[Mesh] OR "Chromium/toxicity"[Mesh]) OR ("Cobalt/adverse effects"[Mesh] OR "Cobalt/poisoning"[Mesh] OR "Cobalt/toxicity"[Mesh])) AND ("Arthroplasty, Replacement, Hip"[Mesh] OR "Hip Prosthesis"[Mesh]). These searches identified 281 unique references, of which 23 contained original case data. Three further reports were identified from the bibliographies of these papers. As some cases were reported repeatedly the 26 papers described only 18 individual cases. Systemic toxicity. Ten of these eighteen patients had undergone revision from a ceramic-containing bearing to one containing a metal component. The other eight had metal-on-metal prostheses. Systemic toxicity was first manifest months and often several years after placement of the metal-containing joint. The reported systemic features fell into three main categories: neuro-ocular toxicity (14 patients), cardiotoxicity (11 patients) and thyroid toxicity (9 patients). Neurotoxicity was manifest as peripheral neuropathy (8 cases), sensorineural hearing loss (7) and cognitive decline (5); ocular toxicity presented as visual impairment (6). All these neurological features, except cognitive decline, have been associated with cobalt poisoning previously. Type of prosthesis and blood metal concentrations. Where blood or serum metal concentrations were reported (n = 17 for cobalt and n = 14 for chromium), the median cobalt concentration was 398 (range, 13.6-6521) μg/L and the median chromium concentration was 48 μg/L (in whole blood) (range, 4.1-221 μg/L including serum and blood values). Those patients reported to have systemic features who had received a metal-on-metal prosthesis (n = 8) had a median peak blood cobalt concentration of 34.5 (range, 13.6-398.6) μg/L; those with a metal-containing revision of a failed ceramic prosthesis (n = 10) had a median blood cobalt concentration of 506 (range, 353-6521) μg/L. Management. The most common treatment was removal of the metal-containing prosthesis, undertaken in all but 2 patients. This was usually associated with a fall in circulating cobalt concentration and improvement in some or all features. Clinical and toxicological assessment of systemic features. We propose the following criteria for assessing the likelihood that clinical features are related to cobalt toxicity: clinical effects consistent with the known neurological, cardiac, or thyroidal effects of cobalt, and for which any other explanation is less likely; increased blood cobalt concentrations (substantially higher than those in patients with well-functioning prostheses) several months after hip replacement; a fall in the blood cobalt concentration, usually accompanied by signs of improvement in features. When judged by these criteria, the systemic features in 10 of the reported cases are likely to be related to cobalt exposure from a metal-containing hip prosthesis.
CONCLUSIONS: Rarely, patients exposed to high circulating concentrations of cobalt from failed hip replacements develop neurological damage, hypothyroidism and/or cardiomyopathy, which may not resolve completely even after removal of the prosthesis. The greatest risk of systemic cobalt toxicity seems to result from accelerated wear of a cobalt-containing revision of a failed ceramic prosthesis, rather than from primary failure of a metal-on-metal prosthesis.

Entities:  

Keywords:  Ceramic; Chromium poisoning; Cobalt poisoning; Cobalt-chromium-molybdenum alloy; Hip prostheses; Hip replacement; Hip resurfacing; Metal-on-metal joint prostheses; Metallosis

Mesh:

Substances:

Year:  2014        PMID: 25132471     DOI: 10.3109/15563650.2014.944977

Source DB:  PubMed          Journal:  Clin Toxicol (Phila)        ISSN: 1556-3650            Impact factor:   4.467


  53 in total

1.  Revision for taper corrosion at the neck-body junction following total hip arthroplasty: pearls and pitfalls.

Authors:  Mitchell C Weiser; Darwin D Chen
Journal:  Curr Rev Musculoskelet Med       Date:  2016-03

2.  Metal wear particles in hematopoietic marrow of the axial skeleton in patients with prior revision for mechanical failure of a hip or knee arthroplasty.

Authors:  Deborah J Hall; Robin Pourzal; Joshua J Jacobs; Robert M Urban
Journal:  J Biomed Mater Res B Appl Biomater       Date:  2018-11-30       Impact factor: 3.368

3.  Cobalt-Induced Ototoxicity in Rat Postnatal Cochlear Organotypic Cultures.

Authors:  Peng Li; Dalian Ding; Richard Salvi; Jerome A Roth
Journal:  Neurotox Res       Date:  2015-07-08       Impact factor: 3.911

4.  'Snake eyes' MRI sign: possible role of cobalt toxicity?

Authors:  Chiara Briani; Mario Cacciavillani; Annamaria Nicolli; Andrea Trevisan; Roberto Gasparotti
Journal:  J Neurol       Date:  2014-12-09       Impact factor: 4.849

5.  Stromal vascular fraction cell therapy for osteoarthritis in elderly: Multicenter case-control study.

Authors:  Jaroslav Michalek; Alena Vrablikova; Adas Darinskas; Ladislav Lukac; Jaroslav Prucha; Josef Skopalik; Jan Travnik; Marek Cibulka; Zuzana Dudasova
Journal:  J Clin Orthop Trauma       Date:  2018-11-23

6.  Fatal Cobalt Cardiomyopathy Following Revision Total Hip Arthroplasty - A Brief Report with Review of Literature.

Authors:  Deepak Gautam; Ashish Pande; Rajesh Malhotra
Journal:  Arch Bone Jt Surg       Date:  2019-07

7.  Pleomorphic clinical spectrum of metallosis in total hip arthroplasty.

Authors:  Francesco Pisanu; Carlo Doria; Matteo Andreozzi; Marco Bartoli; Laura Saderi; Giovanni Sotgiu; Paolo Tranquilli Leali
Journal:  Int Orthop       Date:  2018-09-29       Impact factor: 3.075

8.  Potentiodynamic Corrosion Testing.

Authors:  Selin Munir; Matthew H Pelletier; William R Walsh
Journal:  J Vis Exp       Date:  2016-09-04       Impact factor: 1.355

9.  Metal-on-Metal Hip Joint Prostheses: a Retrospective Case Series Investigating the Association of Systemic Toxicity with Serum Cobalt and Chromium Concentrations.

Authors:  James H Ho; Jerrold B Leikin; Paul I Dargan; John R H Archer; David M Wood; Jeffrey Brent
Journal:  J Med Toxicol       Date:  2017-09-12

Review 10.  Management of metal-on-metal hip implant patients: Who, when and how to revise?

Authors:  Reshid Berber; John A Skinner; Alister J Hart
Journal:  World J Orthop       Date:  2016-05-18
View more