Literature DB >> 27657849

Multiplexed instrument-free meningitis diagnosis on a polymer/paper hybrid microfluidic biochip.

Maowei Dou1, Sharma T Sanjay1, Delfina C Dominguez2, Peng Liu3, Feng Xu4, XiuJun Li5.   

Abstract

Neisseria meningitidis (N. meningitidis), Streptococcus pneumoniae (S. pneumoniae), and Haemophilus influenzae type b (Hib) are three most common pathogens accounting for most bacterial meningitis, a serious global infectious disease with high fatality, especially in developing nations. Because the treatment and antibiotics differ among each type, the identification of the exact bacteria causing the disease is vital. Herein, we report a polymer/paper hybrid microfluidic biochip integrated with loop-mediated isothermal amplification (LAMP) for multiplexed instrument-free diagnosis of these three major types of bacterial meningitis, with high sensitivity and specificity. Results can be visually observed by the naked eye or imaged by a smartphone camera under a portable UV light source. Without using any specialized laboratory instrument, the limits of detection of a few DNA copies per LAMP zone for N. meningitidis, S. pneumoniae and Hib were achieved within 1h. In addition, these three types of microorganisms spiked in artificial cerebrospinal fluid (ACSF) were directly detected simultaneously, avoiding cumbersome sample preparation procedures in conventional methods. Compared with the paper-free non-hybrid microfluidic biochip over a period of three months, the hybrid microfluidic biochip was found to have a much longer shelf life. Hence, this rapid, instrument-free and highly sensitive microfluidic approach has great potential for point-of-care (POC) diagnosis of multiple infectious diseases simultaneously, especially in resource-limited settings. Copyright Â
© 2016 Elsevier B.V. All rights reserved.

Entities:  

Keywords:  Hybrid microfluidic biochip; Instrument-free detection; LAMP; Low-resource settings; Multiplexed meningitis diagnosis

Mesh:

Substances:

Year:  2016        PMID: 27657849      PMCID: PMC5125860          DOI: 10.1016/j.bios.2016.09.033

Source DB:  PubMed          Journal:  Biosens Bioelectron        ISSN: 0956-5663            Impact factor:   10.618


  43 in total

Review 1.  Progress in multiplex loop-mediated isothermal amplification technology.

Authors:  Wen-hui Lin; Bing-jie Zou; Qin-xin Song; Guo-hua Zhou
Journal:  Yi Chuan       Date:  2015-09

2.  Stability of genomic DNA in dried blood spots stored on filter paper.

Authors:  Sumonta Chaisomchit; Rattanawadee Wichajarn; Noppavan Janejai; Wiyada Chareonsiriwatana
Journal:  Southeast Asian J Trop Med Public Health       Date:  2005-01       Impact factor: 0.267

3.  Timely detection of bacterial meningitis epidemics at district level: a study in three countries of the African Meningitis Belt.

Authors:  Lydiane Agier; Hélène Broutin; Eric Bertherat; Mamoudou H Djingarey; Clement Lingani; William Perea; Stéphane Hugonnet
Journal:  Trans R Soc Trop Med Hyg       Date:  2013-01       Impact factor: 2.184

Review 4.  Distance-based microfluidic quantitative detection methods for point-of-care testing.

Authors:  Tian Tian; Jiuxing Li; Yanling Song; Leiji Zhou; Zhi Zhu; Chaoyong James Yang
Journal:  Lab Chip       Date:  2016-04-07       Impact factor: 6.799

5.  Inactivation, storage, and PCR detection of Mycoplasma on FTA filter paper.

Authors:  Hugo Moscoso; Stephan G Thayer; Charles L Hofacre; Stanley H Kleven
Journal:  Avian Dis       Date:  2004-12       Impact factor: 1.577

6.  Development and clinical validation of a loop-mediated isothermal amplification method for the rapid detection of Neisseria meningitidis.

Authors:  James P McKenna; Derek J Fairley; Michael D Shields; Sara L Cosby; Dorothy E Wyatt; Conall McCaughey; Peter V Coyle
Journal:  Diagn Microbiol Infect Dis       Date:  2011-02       Impact factor: 2.803

7.  Real-time PCR assays for the detection and quantification of Streptococcus pneumoniae.

Authors:  Hee Kuk Park; Hee Joong Lee; Hee Jung Lee; Wonyong Kim
Journal:  FEMS Microbiol Lett       Date:  2010-06-18       Impact factor: 2.742

8.  An ensemble of aptamers and antibodies for multivalent capture of cancer cells.

Authors:  Jinling Zhang; Weian Sheng; Z Hugh Fan
Journal:  Chem Commun (Camb)       Date:  2014-06-28       Impact factor: 6.222

9.  Clinical evaluation of a loop-mediated isothermal amplification (LAMP) assay for rapid detection of Neisseria meningitidis in cerebrospinal fluid.

Authors:  DoKyung Lee; Eun Jin Kim; Paul E Kilgore; Soon Ae Kim; Hideyuki Takahashi; Makoto Ohnishi; Dang Duc Anh; Bai Qing Dong; Jung Soo Kim; Jun Tomono; Shigehiko Miyamoto; Tsugunori Notomi; Dong Wook Kim; Mitsuko Seki
Journal:  PLoS One       Date:  2015-04-08       Impact factor: 3.240

10.  Collecting, archiving and processing DNA from wildlife samples using FTA databasing paper.

Authors:  L M Smith; L A Burgoyne
Journal:  BMC Ecol       Date:  2004-04-08       Impact factor: 2.964

View more
  31 in total

1.  A paper/polymer hybrid CD-like microfluidic SpinChip integrated with DNA-functionalized graphene oxide nanosensors for multiplex qLAMP detection.

Authors:  Maowei Dou; Sharma T Sanjay; Delfina C Dominguez; Sihui Zhan; XiuJun Li
Journal:  Chem Commun (Camb)       Date:  2017-10-03       Impact factor: 6.222

2.  Multiplex detection of blood-borne pathogens on a self-driven microfluidic chip using loop-mediated isothermal amplification.

Authors:  Chunmei Xie; Shan Chen; Likun Zhang; Xiangpeng He; Yi Ma; Haiping Wu; Bingjie Zou; Guohua Zhou
Journal:  Anal Bioanal Chem       Date:  2021-03-13       Impact factor: 4.142

3.  Remotely tunable microfluidic platform driven by nanomaterial-mediated on-demand photothermal pumping.

Authors:  Guanglei Fu; Wan Zhou; XiuJun Li
Journal:  Lab Chip       Date:  2020-06-16       Impact factor: 6.799

Review 4.  Recent advances of controlled drug delivery using microfluidic platforms.

Authors:  Sharma T Sanjay; Wan Zhou; Maowei Dou; Hamed Tavakoli; Lei Ma; Feng Xu; XiuJun Li
Journal:  Adv Drug Deliv Rev       Date:  2017-09-15       Impact factor: 15.470

5.  Teicoplanin-functionalized magnetic beads for detection of Staphylococcus aureus via inhibition of the luminol chemiluminescence by intracellular catalase.

Authors:  Yue Wu; Mengyao Wang; Hui Ouyang; Yong He; Xiaoyan Zhao; Zhifeng Fu
Journal:  Mikrochim Acta       Date:  2018-07-28       Impact factor: 5.833

6.  A new method to amplify colorimetric signals of paper-based nanobiosensors for simple and sensitive pancreatic cancer biomarker detection.

Authors:  K Sudhakara Prasad; Yousef Abugalyon; Chunqiang Li; Feng Xu; XiuJun Li
Journal:  Analyst       Date:  2020-06-26       Impact factor: 4.616

7.  Fully 3D printed integrated reactor array for point-of-care molecular diagnostics.

Authors:  Karteek Kadimisetty; Jinzhao Song; Aoife M Doto; Young Hwang; Jing Peng; Michael G Mauk; Frederic D Bushman; Robert Gross; Joseph N Jarvis; Changchun Liu
Journal:  Biosens Bioelectron       Date:  2018-03-10       Impact factor: 10.618

8.  A Low-Cost Nanomaterial-based Electrochemical Immunosensor on Paper for High-Sensitivity Early Detection of Pancreatic Cancer.

Authors:  K Sudhakara Prasad; Xiyue Cao; Ning Gao; Qijie Jin; Sharma T Sanjay; Gilberto Henao-Pabon; XiuJun Li
Journal:  Sens Actuators B Chem       Date:  2019-12-02       Impact factor: 7.460

9.  Exploration of Nanoparticle-Mediated Photothermal Effect of TMB-H2O2 Colorimetric System and Its Application in a Visual Quantitative Photothermal Immunoassay.

Authors:  Guanglei Fu; Sharma T Sanjay; Wan Zhou; Rolf A Brekken; Robert A Kirken; XiuJun Li
Journal:  Anal Chem       Date:  2018-04-17       Impact factor: 6.986

Review 10.  Aptamer-functionalized metal-organic frameworks (MOFs) for biosensing.

Authors:  Mengzhen Lv; Wan Zhou; Hamed Tavakoli; Cynthia Bautista; Jianfei Xia; Zonghua Wang; XiuJun Li
Journal:  Biosens Bioelectron       Date:  2020-12-30       Impact factor: 10.618

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.