Literature DB >> 21251556

Development and clinical validation of a loop-mediated isothermal amplification method for the rapid detection of Neisseria meningitidis.

James P McKenna1, Derek J Fairley, Michael D Shields, Sara L Cosby, Dorothy E Wyatt, Conall McCaughey, Peter V Coyle.   

Abstract

Loop-mediated isothermal amplification (LAMP) is an innovative technique that allows the rapid detection of target nucleic acid sequences under isothermal conditions without the need for complex instrumentation. The development, optimization, and clinical validation of a LAMP assay targeting the ctrA gene for the rapid detection of capsular Neisseria meningitidis were described. Highly specific detection of capsular N. meningitidis type strains and clinical isolates was demonstrated, with no cross-reactivity with other Neisseria spp. or with a comprehensive panel of other common human pathogens. The lower limit of detection was 6 ctrA gene copies detectable in 48 min, with positive reactions readily identifiable visually via a simple color change. Higher copy numbers could be detected in as little as 16 min. When applied to a total of 394 clinical specimens, the LAMP assay in comparison to a conventional TaqMan® based real-time polymerase chain reaction system demonstrated a sensitivity of 100% and a specificity of 98.9% with a κ coefficient of 0.942. The LAMP method represents a rapid, sensitive, and highly specific technique for the detection of N. meningitidis and has the potential to be used as a point-of-care molecular test and in resource-poor settings. Copyright Â
© 2011 Elsevier Inc. All rights reserved.

Entities:  

Mesh:

Year:  2011        PMID: 21251556     DOI: 10.1016/j.diagmicrobio.2010.10.008

Source DB:  PubMed          Journal:  Diagn Microbiol Infect Dis        ISSN: 0732-8893            Impact factor:   2.803


  17 in total

1.  Validation of a New Rapid Detection Test for Detection of Neisseria meningitidis A/C/W/X/Y Antigens in Cerebrospinal Fluid.

Authors:  Cyrille H Haddar; Aude Terrade; Paul Verhoeven; Berthe-Marie Njanpop-Lafourcade; Mireille Dosso; Fati Sidikou; Ali Elhaj Mahamane; Jean-Pierre Lombart; Aziza Razki; Eva Hong; Alain Agnememel; Evelyne Begaud; Yves Germani; Bruno Pozzetto; Muhamed-Kheir Taha
Journal:  J Clin Microbiol       Date:  2020-02-24       Impact factor: 5.948

2.  Multiplexed instrument-free meningitis diagnosis on a polymer/paper hybrid microfluidic biochip.

Authors:  Maowei Dou; Sharma T Sanjay; Delfina C Dominguez; Peng Liu; Feng Xu; XiuJun Li
Journal:  Biosens Bioelectron       Date:  2016-09-12       Impact factor: 10.618

3.  COMPARISON OF METHODS TO IDENTIFY Neisseria meningitidis IN ASYMPTOMATIC CARRIERS.

Authors:  Camila F Rizek; André Machado Luiz; Gracilene Ramos de Assis; Silvia Figueiredo Costa; Anna Sara Levin; Marta Heloisa Lopes
Journal:  Rev Inst Med Trop Sao Paulo       Date:  2016-09-22       Impact factor: 1.846

4.  Visual detection and evaluation of latent and lytic gene expression during Epstein-Barr virus infection using one-step reverse transcription loop-mediated isothermal amplification.

Authors:  Xiaoying Liu; Jingfeng Tang; Man Wang; Qiang Ma; Yefu Wang
Journal:  Int J Mol Sci       Date:  2013-12-09       Impact factor: 5.923

5.  Clinical evaluation of a loop-mediated isothermal amplification (LAMP) assay for rapid detection of Neisseria meningitidis in cerebrospinal fluid.

Authors:  DoKyung Lee; Eun Jin Kim; Paul E Kilgore; Soon Ae Kim; Hideyuki Takahashi; Makoto Ohnishi; Dang Duc Anh; Bai Qing Dong; Jung Soo Kim; Jun Tomono; Shigehiko Miyamoto; Tsugunori Notomi; Dong Wook Kim; Mitsuko Seki
Journal:  PLoS One       Date:  2015-04-08       Impact factor: 3.240

6.  Development of a rapid, simple method for detecting Naegleria fowleri visually in water samples by loop-mediated isothermal amplification (LAMP).

Authors:  Aongart Mahittikorn; Hirotake Mori; Supaluk Popruk; Amonrattana Roobthaisong; Chantira Sutthikornchai; Khuanchai Koompapong; Sukhontha Siri; Yaowalark Sukthana; Duangporn Nacapunchai
Journal:  PLoS One       Date:  2015-03-30       Impact factor: 3.240

Review 7.  Loop-Mediated Isothermal Amplification Methods for Diagnosis of Bacterial Meningitis.

Authors:  Mitsuko Seki; Paul E Kilgore; Eun Jin Kim; Makoto Ohnishi; Satoshi Hayakawa; Dong Wook Kim
Journal:  Front Pediatr       Date:  2018-03-12       Impact factor: 3.418

8.  Evaluation of an Internally Controlled Multiplex Tth Endonuclease Cleavage Loop-Mediated Isothermal Amplification (TEC-LAMP) Assay for the Detection of Bacterial Meningitis Pathogens.

Authors:  Owen Higgins; Eoin Clancy; Martin Cormican; Teck Wee Boo; Robert Cunney; Terry J Smith
Journal:  Int J Mol Sci       Date:  2018-02-09       Impact factor: 5.923

9.  Development of Loop-Mediated Isothermal Amplification Assay for Detection of Clinically Significant Members of Acinetobacter calcoaceticus-baumannii Complex and Associated Carbapenem Resistance.

Authors:  Amit Sharma; Rajni Gaind
Journal:  Front Mol Biosci       Date:  2021-06-23

10.  A versatile PDMS/paper hybrid microfluidic platform for sensitive infectious disease diagnosis.

Authors:  Maowei Dou; Delfina C Dominguez; XiuJun Li; Juan Sanchez; Gabriel Scott
Journal:  Anal Chem       Date:  2014-07-24       Impact factor: 6.986

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.