Ryosuke Tozawa1, Munenori Katoh2, Hidefumi Aramaki2, Tsubasa Kawasaki2, Yuichi Nishikawa3, Tsuneo Kumamoto4, Osamu Fujinawa4.
Abstract
[Purpose] The intra- and inter-examiner reliabilities of lumbar interspinous process distances measured by ultrasound imaging were examined.Entities:
Keywords: Lumbar interspinous process; Reliability; Ultrasound imaging
Year: 2016 PMID: 27630399 PMCID: PMC5011563 DOI: 10.1589/jpts.28.2210
Source DB: PubMed Journal: J Phys Ther Sci ISSN: 0915-5287
Fig. 1.Selection method of captured US images
Fig. 2.Method of measuring the caliper and L1–2 interspinous process image. CRE: cranial end, CAE: caudal end, Top: spinous top
Intra- and inter-examiner reliabilities of the lumbar interspinous process measurements
| Intra-examiner reliability | ||
|---|---|---|
| Measurer | ICC (1, 1) | 95% Confidence interval |
| A | 0.997 | 0.993–0.999 |
| B | 0.992 | 0.981–0.998 |
| C | 0.998 | 0.996–0.999 |
| D | 0.985 | 0.963–0.996 |
| E | 0.991 | 0.978–0.997 |
| F | 0.995 | 0.987–0.998 |
| G | 0.995 | 0.987–0.999 |
| H | 0.992 | 0.980–0.998 |
| I | 0.990 | 0.977–0.997 |
| Inter-examiner reliability | ||
| Number of measurers | ICC (2, 1) | 95% Confidence interval |
| n=9 | 0.969 | 0.896–0.996 |
Intra-examiner reliability of the test–retest
| Measurer | ICC (1, 2) | 95% Confidence interval |
|---|---|---|
| D | 0.991 | 0.993–0.999 |
| F | 0.996 | 0.981–0.998 |
| H | 0.999 | 0.963–0.996 |
| I | 0.993 | 0.978–0.997 |
SEM, MDC95, and results of the Bland–Altman analysis between the test and retest
| Measurer | Fixed bias | Proportional bias | SEM (mm) | MDC95 (mm) | ||
|---|---|---|---|---|---|---|
| 95% Confidence interval | Result | Regression line | Result | |||
| D | −0.857–0.457 | no | 0.012 p=0.867 | no | 0.650 | 1.801 |
| F | −0.506–0.306 | no | 0.009 p=0.838 | no | 0.401 | 1.113 |
| H | −0.126–0.326 | no | −0.013 p=0.613 | no | 0.224 | 0.620 |
| I | −0.364–0.764 | no | 0.041 p=0.509 | no | 0.558 | 1.546 |