Automatic tube current modulation for whole-body polytrauma CT with immobilization devices: is there an increase in radiation dose and degradation of image quality?

André Euler1,2, Bram Stieltjes3, Sebastian T Schindera3.   

Abstract

The objective of this study was the assessment of the image quality and radiation dose in polytrauma CT using immobilization devices. An anthropomorphic whole body and a liver phantom were scanned on a 128-slice CT scanner with four different protocols using automatic tube current modulation (120 kVp, 150 ref. mAs; 120 kV, 200 ref. mAs; 140 kVp, 150 ref. mAs; and 140 kVp, 200 ref. mAs) and four different setups (no immobilization device (setup A), vacuum mattress 1 (setup B), vacuum mattress 2 (setup C), and spineboard (setup D)). Qualitative and quantitative image quality parameters and radiation dose were assessed. Image noise increased on average by 6.6, 11.2, and 9.4 %, and CNR decreased by 11.2, 13.9, and 6.5 for setups B, C, and D, respectively, compared with setup A. The CTDIvol increased up to 6 % using immobilization devices. Severe streak artifacts, provoked by the inflation valve of the mattresses were detected at the level of the head and shoulder. Applying immobilization devices for whole-body CT with automatic tube current modulation increases the radiation dose and decreases the quantitative image quality slightly. Severe artifacts, induced by the inflation valve of the mattress, can influence the diagnostic accuracy at the level of the head and shoulder.

Entities:  

Keywords:  Image quality; Multislice computed tomography; Polytrauma; Spineboard; Vacuum mattress

Mesh:

Year:  2016        PMID: 27614884     DOI: 10.1007/s10140-016-1442-x

Source DB:  PubMed          Journal:  Emerg Radiol        ISSN: 1070-3004


  13 in total

1.  [Evaluation of spine boards for X-Ray diagnostics].

Authors:  U Linsenmaier; M Krötz; K G Kanz; W Russ; E Papst; J Rieger; W Mutscher; K J Pfeifer
Journal:  Rofo       Date:  2001-11

2.  In search of the most suitable technique for truncal spinal immobilization with associated radiography.

Authors:  J Schou; H Kiermayer; W Ummenhofer; H P Herion
Journal:  Eur J Emerg Med       Date:  2001-06       Impact factor: 2.799

3.  The 2007 Recommendations of the International Commission on Radiological Protection. ICRP publication 103.

Authors: 
Journal:  Ann ICRP       Date:  2007

4.  Metal Artifact Reduction in Pelvic Computed Tomography With Hip Prostheses: Comparison of Virtual Monoenergetic Extrapolations From Dual-Energy Computed Tomography and an Iterative Metal Artifact Reduction Algorithm in a Phantom Study.

Authors:  Kai Higashigaito; Florian Angst; Val M Runge; Hatem Alkadhi; Olivio F Donati
Journal:  Invest Radiol       Date:  2015-12       Impact factor: 6.016

5.  Computed tomography in trauma patients using iterative reconstruction: reducing radiation exposure without loss of image quality.

Authors:  Johannes Kahn; Ulrich Grupp; David Kaul; Georg Böning; Tobias Lindner; Florian Streitparth
Journal:  Acta Radiol       Date:  2015-04-06       Impact factor: 1.990

Review 6.  Techniques and applications of automatic tube current modulation for CT.

Authors:  Mannudeep K Kalra; Michael M Maher; Thomas L Toth; Bernhard Schmidt; Bryan L Westerman; Hugh T Morgan; Sanjay Saini
Journal:  Radiology       Date:  2004-10-21       Impact factor: 11.105

7.  [Modern CT diagnosis of acute thoracic and abdominal trauma].

Authors:  M Rieger; H Sparr; R Esterhammer; C Fink; R Bale; B Czermak; W Jaschke
Journal:  Radiologe       Date:  2002-07       Impact factor: 0.635

8.  CT Metal Artifact Reduction in the Spine: Can an Iterative Reconstruction Technique Improve Visualization?

Authors:  A L Kotsenas; G J Michalak; D R DeLone; F E Diehn; K Grant; A F Halaweish; A Krauss; R Raupach; B Schmidt; C H McCollough; J G Fletcher
Journal:  AJNR Am J Neuroradiol       Date:  2015-08-06       Impact factor: 3.825

9.  Effect of whole-body CT during trauma resuscitation on survival: a retrospective, multicentre study.

Authors:  Stefan Huber-Wagner; Rolf Lefering; Lars-Mikael Qvick; Markus Körner; Michael V Kay; Klaus-Jürgen Pfeifer; Maximilian Reiser; Wolf Mutschler; Karl-Georg Kanz
Journal:  Lancet       Date:  2009-03-25       Impact factor: 79.321

10.  Immediate total-body CT scanning versus conventional imaging and selective CT scanning in patients with severe trauma (REACT-2): a randomised controlled trial.

Authors:  Joanne C Sierink; Kaij Treskes; Michael J R Edwards; Benn J A Beuker; Dennis den Hartog; Joachim Hohmann; Marcel G W Dijkgraaf; Jan S K Luitse; Ludo F M Beenen; Markus W Hollmann; J Carel Goslings
Journal:  Lancet       Date:  2016-06-28       Impact factor: 79.321

View more
  1 in total

1.  Maintaining immobilisation devices on trauma patients during CT: a feasibility study.

Authors:  Pål Johan Stokkeland; Erlend Andersen; Maria Myhre Bjørndal; Arne Morten Mikalsen; Sindre Aslaksen; Per Kristian Hyldmo
Journal:  Scand J Trauma Resusc Emerg Med       Date:  2017-08-23       Impact factor: 2.953