Literature DB >> 11704915

[Evaluation of spine boards for X-Ray diagnostics].

U Linsenmaier1, M Krötz, K G Kanz, W Russ, E Papst, J Rieger, W Mutscher, K J Pfeifer.   

Abstract

PURPOSE: Spine boards are frequently used in preclinical emergency care. Different models were examined with regard to their feasibility for plain film radiography and computed tomography (CT).
METHODS: Five current spine board models were measured for their dimensions and weight. Transmission of radiation [microGyls] and dose area product [cGy x cm(2)] were determined with a patient equivalent aluminium phantom. Image artifacts, image quality and resolution of anatomic details were evaluated with an anthropomorphic Alderson phantom.
RESULTS: With only 6.3 kg new models show a 28 % reduction in weight, three spine boards generate lateral artifacts due to a narrow width of 41 - 42 cm. Radiation transmission of all boards was similar, however dose area products differed by up to 59 %. Image quality was impaired in 4 out of 5 boards because of image artifacts, CT scanning was not impaired with all boards.
CONCLUSION: Only one board (Ferno Millenia(R)) showed sufficient properties for plain film radiography and CT. There is no suitable spine board for preclinical and clinical applications as well as for trauma radiology, further improvements of current designs are essential.

Entities:  

Mesh:

Year:  2001        PMID: 11704915     DOI: 10.1055/s-2001-18311

Source DB:  PubMed          Journal:  Rofo        ISSN: 1438-9010


  3 in total

1.  Automatic tube current modulation for whole-body polytrauma CT with immobilization devices: is there an increase in radiation dose and degradation of image quality?

Authors:  André Euler; Bram Stieltjes; Sebastian T Schindera
Journal:  Emerg Radiol       Date:  2016-09-10

2.  Rings and things on upper extremity radiographs of emergency patients.

Authors:  Matthew L Steinway; Mihra S Taljanovic; Tim B Hunter; Elizabeth A Krupinski; William A Grana
Journal:  Emerg Radiol       Date:  2003-03-22

3.  Effect of spinal immobilisation devices on radiation exposure in conventional radiography and computed tomography.

Authors:  Baukje Hemmes; Cécile R L P N Jeukens; Gerrit J Kemerink; Peter R G Brink; Martijn Poeze
Journal:  Emerg Radiol       Date:  2016-01-11
  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.