BACKGROUND: In this treatment planning study, we compare the plan quality and delivery parameters for the treatment of multiple brain metastases using 2 monoisocentric techniques: the Multiple Metastases Element from Brainlab and the RapidArc volumetric-modulated arc therapy from Varian Medical Systems.
METHODS: Eight patients who were treated in our institution for multiple metastases (3-7 lesions) were replanned with Multiple Metastases Element using noncoplanar dynamic conformal arcs. The same patients were replanned with the RapidArc technique in Eclipse using 4 noncoplanar arcs. Both techniques were designed using a single isocenter. Plan quality metrics (conformity index, homogeneity index, gradient index, and R50%), monitor unit, and the planning time were recorded. Comparison of the Multiple Metastases Element and RapidArc plans was performed using Shapiro-Wilk test, paired Student t test, and Wilcoxon signed rank test.
RESULTS: A paired Wilcoxon signed rank test between Multiple Metastases Element and RapidArc showed comparable plan quality metrics and dose to brain. Mean ± standard deviation values of conformity index were 1.8 ± 0.7 and 1.7 ± 0.6, homogeneity index were 1.3 ± 0.1 and 1.3 ± 0.1, gradient index were 5.0 ± 1.8 and 5.1 ± 1.9, and R50% were 4.9 ± 1.8 and 5.0 ± 1.9 for Multiple Metastases Element and RapidArc plans, respectively. Mean brain dose was 2.3 and 2.7 Gy for Multiple Metastases Element and RapidArc plans, respectively. The mean value of monitor units in Multiple Metastases Element plan was 7286 ± 1065, which is significantly lower than the RapidArc monitor units of 9966 ± 1533 ( P < .05).
CONCLUSION: For the planning of multiple brain lesions to be treated with stereotactic radiosurgery, Multiple Metastases Element planning software produced equivalent conformity, homogeneity, dose falloff, and brain V12 Gy but required significantly lower monitor units, when compared to RapidArc plans.

Entities:  

Keywords:  monoisocentric; multiple metastases; stereotactic radiosurgery

Mesh:

Year:  2016        PMID: 27612917      PMCID: PMC5665155          DOI: 10.1177/1533034616666998

Source DB:  PubMed          Journal:  Technol Cancer Res Treat        ISSN: 1533-0338


  17 in total

1.  Radiotherapy x-ray dose distribution beyond air cavities.

Authors:  T P Wong; P E Metcalfe; T Kron; T G Emeleus
Journal:  Australas Phys Eng Sci Med       Date:  1992-09       Impact factor: 1.430

2.  Stereotactic body radiation therapy: the report of AAPM Task Group 101.

Authors:  Stanley H Benedict; Kamil M Yenice; David Followill; James M Galvin; William Hinson; Brian Kavanagh; Paul Keall; Michael Lovelock; Sanford Meeks; Lech Papiez; Thomas Purdie; Ramaswamy Sadagopan; Michael C Schell; Bill Salter; David J Schlesinger; Almon S Shiu; Timothy Solberg; Danny Y Song; Volker Stieber; Robert Timmerman; Wolfgang A Tomé; Dirk Verellen; Lu Wang; Fang-Fang Yin
Journal:  Med Phys       Date:  2010-08       Impact factor: 4.071

Review 3.  Management of brain metastases.

Authors:  Kristin A Bradley; Minesh P Mehta
Journal:  Semin Oncol       Date:  2004-10       Impact factor: 4.929

4.  Volumetric modulated arc therapy: IMRT in a single gantry arc.

Authors:  Karl Otto
Journal:  Med Phys       Date:  2008-01       Impact factor: 4.071

5.  A simple dose gradient measurement tool to complement the conformity index.

Authors:  Ian Paddick; Bodo Lippitz
Journal:  J Neurosurg       Date:  2006-12       Impact factor: 5.115

6.  Comparison of radiation dose spillage from the Gamma Knife Perfexion with that from volumetric modulated arc radiosurgery during treatment of multiple brain metastases in a single fraction.

Authors:  Daniel McDonald; John Schuler; Istvan Takacs; Jean Peng; Joseph Jenrette; Kenneth Vanek
Journal:  J Neurosurg       Date:  2014-12       Impact factor: 5.115

7.  Single dose radiosurgical treatment of recurrent previously irradiated primary brain tumors and brain metastases: final report of RTOG protocol 90-05.

Authors:  E Shaw; C Scott; L Souhami; R Dinapoli; R Kline; J Loeffler; N Farnan
Journal:  Int J Radiat Oncol Biol Phys       Date:  2000-05-01       Impact factor: 7.038

8.  Initial experience with volumetric IMRT (RapidArc) for intracranial stereotactic radiosurgery.

Authors:  Charles S Mayo; Linda Ding; Anthony Addesa; Sidney Kadish; T J Fitzgerald; Richard Moser
Journal:  Int J Radiat Oncol Biol Phys       Date:  2010-03-06       Impact factor: 7.038

9.  Intensity modulation with photons for benign intracranial tumours: a planning comparison of volumetric single arc, helical arc and fixed gantry techniques.

Authors:  Antonella Fogliata; Alessandro Clivio; Giorgia Nicolini; Eugenio Vanetti; Luca Cozzi
Journal:  Radiother Oncol       Date:  2008-08-28       Impact factor: 6.280

10.  Single fraction radiosurgery using Rapid Arc for treatment of intracranial targets.

Authors:  Hendrik A Wolff; Daniela M Wagner; Hans Christiansen; Clemens F Hess; Hilke Vorwerk
Journal:  Radiat Oncol       Date:  2010-09-13       Impact factor: 3.481

View more
  10 in total

1.  Evaluation of two automated treatment planning techniques for multiple brain metastases using a single isocenter.

Authors:  Guoqiang Cui; Yun Yang; Fang-Fang Yin; David Yoo; Grace Kim; Jun Duan
Journal:  J Radiosurg SBRT       Date:  2022

2.  Interinstitutional Plan Quality Assessment of 2 Linac-Based, Single-Isocenter, Multiple Metastasis Radiosurgery Techniques.

Authors:  Haisong Liu; Evan M Thomas; Jun Li; Yan Yu; David Andrews; James M Markert; John B Fiveash; Wenyin Shi; Richard A Popple
Journal:  Adv Radiat Oncol       Date:  2019-12-02

3.  Single isocenter stereotactic radiosurgery for patients with multiple brain metastases: dosimetric comparison of VMAT and a dedicated DCAT planning tool.

Authors:  Jan Hofmaier; Raphael Bodensohn; Sylvia Garny; Indrawati Hadi; Daniel F Fleischmann; Michael Eder; Yavuz Dinc; Michael Reiner; Stefanie Corradini; Katia Parodi; Claus Belka; Maximilian Niyazi
Journal:  Radiat Oncol       Date:  2019-06-11       Impact factor: 3.481

4.  Dosimetric impact of rotational errors on the quality of VMAT-SRS for multiple brain metastases: Comparison between single- and two-isocenter treatment planning techniques.

Authors:  Georgia Prentou; Eleftherios P Pappas; Andreas Logothetis; Efi Koutsouveli; Evaggelos Pantelis; Panagiotis Papagiannis; Pantelis Karaiskos
Journal:  J Appl Clin Med Phys       Date:  2020-02-05       Impact factor: 2.102

5.  Optimizing radiosurgery with photons for ocular melanoma.

Authors:  I Frank Ciernik; Markus Wösle; Lothar Krause; Jérôme Krayenbuehl
Journal:  Phys Imaging Radiat Oncol       Date:  2018-06-19

6.  Single isocenter treatment planning techniques for stereotactic radiosurgery of multiple cranial metastases.

Authors:  Christian Velten; Rafi Kabarriti; Madhur Garg; Wolfgang A Tomé
Journal:  Phys Imaging Radiat Oncol       Date:  2021-01-20

7.  Evaluating the accuracy of geometrical distortion correction of magnetic resonance images for use in intracranial brain tumor radiotherapy.

Authors:  Seyed Mehdi Bagherimofidi; Claus Chunli Yang; Roberto Rey-Dios; Madhava R Kanakamedala; Ali Fatemi
Journal:  Rep Pract Oncol Radiother       Date:  2019-10-19

8.  MRI-Related Geometric Distortions in Stereotactic Radiotherapy Treatment Planning: Evaluation and Dosimetric Impact.

Authors:  Eleftherios P Pappas; Mukhtar Alshanqity; Argyris Moutsatsos; Hani Lababidi; Khalid Alsafi; Konstantinos Georgiou; Pantelis Karaiskos; Evangelos Georgiou
Journal:  Technol Cancer Res Treat       Date:  2017-10-11

9.  GammaKnife versus VMAT radiosurgery plan quality for many brain metastases.

Authors:  Peter S Potrebko; Andrew Keller; Sean All; Samir Sejpal; Julie Pepe; Kunal Saigal; Shravan Kandula; William F Sensakovic; Ravi Shridhar; Jan Poleszczuk; Matthew Biagioli
Journal:  J Appl Clin Med Phys       Date:  2018-10-04       Impact factor: 2.102

10.  Dosimetric quality and delivery efficiency of robotic radiosurgery for brain metastases: Comparison with C-arm linear accelerator based plans.

Authors:  Shuming Zhang; Ruijie Yang; Xin Wang
Journal:  J Appl Clin Med Phys       Date:  2019-10-03       Impact factor: 2.102

  10 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.