Literature DB >> 18065842

An exact approach to direct aperture optimization in IMRT treatment planning.

Chunhua Men1, H Edwin Romeijn, Z Caner Taşkin, James F Dempsey.   

Abstract

We consider the problem of intensity-modulated radiation therapy (IMRT) treatment planning using direct aperture optimization. While this problem has been relatively well studied in recent years, most approaches employ a heuristic approach to the generation of apertures. In contrast, we use an exact approach that explicitly formulates the fluence map optimization (FMO) problem as a convex optimization problem in terms of all multileaf collimator (MLC) deliverable apertures and their associated intensities. However, the number of deliverable apertures, and therefore the number of decision variables and constraints in the new problem formulation, is typically enormous. To overcome this, we use an iterative approach that employs a subproblem whose optimal solution either provides a suitable aperture to add to a given pool of allowable apertures or concludes that the current solution is optimal. We are able to handle standard consecutiveness, interdigitation and connectedness constraints that may be imposed by the particular MLC system used, as well as jaws-only delivery. Our approach has the additional advantage that it can explicitly account for transmission of dose through the part of an aperture that is blocked by the MLC system, yielding a more precise assessment of the treatment plan than what is possible using a traditional beamlet-based FMO problem. Finally, we develop and test two stopping rules that can be used to identify treatment plans of high clinical quality that are deliverable very efficiently. Tests on clinical head-and-neck cancer cases showed the efficacy of our approach, yielding treatment plans comparable in quality to plans obtained by the traditional method with a reduction of more than 75% in the number of apertures and a reduction of more than 50% in beam-on time, with only a modest increase in computational effort. The results also show that delivery efficiency is very insensitive to the addition of traditional MLC constraints; however, jaws-only treatment requires about a doubling in beam-on time and number of apertures used. Finally, we showed the importance of accounting for transmission effects when assessing or, preferably, optimizing treatment plan quality.

Entities:  

Mesh:

Year:  2007        PMID: 18065842     DOI: 10.1088/0031-9155/52/24/009

Source DB:  PubMed          Journal:  Phys Med Biol        ISSN: 0031-9155            Impact factor:   3.609


  11 in total

1.  Sensitivity analysis for lexicographic ordering in radiation therapy treatment planning.

Authors:  T Long; M Matuszak; M Feng; B A Fraass; R K Ten Haken; H E Romeijn
Journal:  Med Phys       Date:  2012-06       Impact factor: 4.071

2.  Simultaneous beam sampling and aperture shape optimization for SPORT.

Authors:  Masoud Zarepisheh; Ruijiang Li; Yinyu Ye; Lei Xing
Journal:  Med Phys       Date:  2015-02       Impact factor: 4.071

3.  Optimization of rotational arc station parameter optimized radiation therapy.

Authors:  P Dong; B Ungun; S Boyd; L Xing
Journal:  Med Phys       Date:  2016-09       Impact factor: 4.071

4.  Deterministic direct aperture optimization using multiphase piecewise constant segmentation.

Authors:  Dan Nguyen; Daniel O'Connor; Dan Ruan; Ke Sheng
Journal:  Med Phys       Date:  2017-09-22       Impact factor: 4.071

5.  Using deep learning to predict beam-tunable Pareto optimal dose distribution for intensity-modulated radiation therapy.

Authors:  Gyanendra Bohara; Azar Sadeghnejad Barkousaraie; Steve Jiang; Dan Nguyen
Journal:  Med Phys       Date:  2020-08-02       Impact factor: 4.071

Review 6.  GPU-based high-performance computing for radiation therapy.

Authors:  Xun Jia; Peter Ziegenhein; Steve B Jiang
Journal:  Phys Med Biol       Date:  2014-02-03       Impact factor: 3.609

7.  Deliverable navigation for multicriteria step and shoot IMRT treatment planning.

Authors:  David Craft; Christian Richter
Journal:  Phys Med Biol       Date:  2012-12-06       Impact factor: 3.609

8.  A column-generation-based method for multi-criteria direct aperture optimization.

Authors:  Ehsan Salari; Jan Unkelbach
Journal:  Phys Med Biol       Date:  2013-01-14       Impact factor: 3.609

9.  A two-stage sequential linear programming approach to IMRT dose optimization.

Authors:  Hao H Zhang; Robert R Meyer; Jianzhou Wu; Shahid A Naqvi; Leyuan Shi; Warren D D'Souza
Journal:  Phys Med Biol       Date:  2010-01-14       Impact factor: 3.609

10.  A comprehensive formulation for volumetric modulated arc therapy planning.

Authors:  Dan Nguyen; Qihui Lyu; Dan Ruan; Daniel O'Connor; Daniel A Low; Ke Sheng
Journal:  Med Phys       Date:  2016-07       Impact factor: 4.071

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.