| Literature DB >> 27555901 |
Yong-Ho Seo1, Eun-Bin Bae1, Jung-Woo Kim1, So-Hyoun Lee1, Mi-Jung Yun1, Chang-Mo Jeong1, Young-Chan Jeon1, Jung-Bo Huh1.
Abstract
PURPOSE: The aim of this study was to evaluate the clinical findings and patient satisfaction on implant overdenture designed with Locator implant attachment or Locator bar attachment in mandibular edentulous patients.Entities:
Keywords: Clinical complication; Edentulous mandible; Implant overdenture; Locator bar attachment; Locator implant attachment
Year: 2016 PMID: 27555901 PMCID: PMC4993845 DOI: 10.4047/jap.2016.8.4.313
Source DB: PubMed Journal: J Adv Prosthodont ISSN: 2005-7806 Impact factor: 1.904
Data of patients and implants
| Patient | Gender | Age (y) | Follow-up (mo) | Implants manufacturer | No. placed | No. lost | Attachment design | Maxillary dentition |
|---|---|---|---|---|---|---|---|---|
| 1 | M | 76 | 16 | Osstem* | 2 | 0 | Stud type | Complete denture |
| 2 | M | 77 | 16 | Straumann† | 2 | 0 | Stud type | Complete denture |
| 3 | F | 64 | 25 | Osstem | 2 | 0 | Stud type | Complete denture |
| 4 | M | 71 | 46 | 3i‡ | 2 | 0 | Stud type | Complete denture |
| 5 | F | 84 | 36 | Osstem | 2 | 0 | Stud type | Implant-retained overdenture |
| 6 | M | 68 | 40 | Cowellmedi§ | 2 | 0 | Stud type | Complete denture |
| 7 | F | 64 | 30 | Osstem | 2 | 0 | Stud type | Removable partial denture |
| 8 | F | 58 | 16 | Osstem | 2 | 0 | Stud type | Complete denture |
| 9 | F | 68 | 18 | Osstem | 4 | 0 | Bar type | Complete denture |
| 10 | F | 68 | 26 | Osstem | 4 | 0 | Bar type | Complete denture |
| 11 | F | 59 | 31 | Osstem | 4 | 0 | Bar type | Removable partial denture |
| 12 | F | 62 | 26 | 3i | 4 | 0 | Bar type | Complete denture |
| 13 | F | 80 | 13 | Osstem | 4 | 0 | Bar type | Complete denture |
| 14 | F | 64 | 40 | Osstem | 4 | 0 | Bar type | Complete denture |
| 15 | M | 76 | 13 | Osstem | 4 | 0 | Bar type | Removable partial denture |
| 16 | F | 70 | 56 | Osstem | 4 | 0 | Bar type | Complete denture |
*Osstem Implant Co., Seoul South Korea; †Institut Straumann AG., Waldenburg, Switzerland, ‡3i Implant Innovations Inc., Florida, USA, §Cowellmedi Co., Busan, South Korea.
Fig. 1Intraoral view of implant overdenture attachment. (A) LIA group: Locator implant attachment utilized with two implants, (B) LBA group: Locator bar attachment utilized with four implants splinted with a bar.
Cumulative survival rate of the implants
| LIA group | LBA group | |||||||
|---|---|---|---|---|---|---|---|---|
| After placement (mo) | Overdentures (N) | Implants (N) | Failed implants (N) | CSR (%) | Overdentures (N) | Implants (N) | Failed implants (N) | CSR (%) |
| 12 - 24 | 3 | 6 | - | 100 | 4 | 16 | - | 100 |
| 25 - 36 | 3 | 6 | - | 100 | 3 | 12 | - | 100 |
| 37 - 48 | 2 | 4 | - | 100 | 1 | 4 | - | 100 |
| over 48 | - | - | - | - | 1 | 4 | - | 100 |
LIA group: Locator implant attachment group, LBA group: Locator bar attachment group, SR: cumulative survival rate of implants.
The average value of the marginal bone resorption and probing depth
| LIA group | LBA group | ||||
|---|---|---|---|---|---|
| Mean | SD | Mean | SD | ||
| Marginal bone resorption (mm) | 1.96 | 0.20 | 1.51 | 0.13 | .04* |
| Probing depth (mm) | 2.91 | 0.24 | 2.80 | 0.16 | .02* |
LIA group: Locator implant attachment group, LBA group: Locator bar attachment group.
*Mean values showed significant difference based on independent T-test (P < .05).
Peri-implant inflammation, bleeding index, plaque index, and calculus
| Implant number | LIA group† | LBA group† | ||
|---|---|---|---|---|
| 16 | 32 | |||
| Peri-implant inflammation (%) | 0 | 87.5 | 66.7 | .125 |
| 1 | 12.5 | 33.3 | ||
| 2 | 0 | 0 | ||
| 3 | 0 | 0 | ||
| Bleeding index (%) | 0 | 37.5 | 26.7 | .094 |
| 1 | 50 | 73.3 | ||
| 2 | 12.5 | 0 | ||
| 3 | 0 | 0 | ||
| Plaque index (%) | 0 | 25 | 0 | .001* |
| 1 | 62.5 | 40 | ||
| 2 | 12.5 | 20 | ||
| 3 | 0 | 40 | ||
| Calculus (%) | 0 | 100 | 75 | .002* |
| 1 | 0 | 25 |
LIA group: Locator implant attachment group, LBA group: Locator bar attachment group.
†Frequency distribution of gingival inflammation, bleeding index, plaque index, and calculus.
*Frequency distribution showed significant difference based on the chi-square test (P < .05).
Correlation among marginal bone resorption, plaque index, and probing depth (R: Pearson's correlation coefficient)
| Plaque index | Probing depth | |||
|---|---|---|---|---|
| R | R | |||
| Marginal bone resorption | -0.213 | .154 | 0.606 | .001* |
*Probing depth significantly correlated with marginal bone resorption based on Pearson's chi-square test (P < .05).
Type of clinical complication
| LIA group | LBA group | |
|---|---|---|
| Replacement of Locator patrix | 9 | 6 |
| Artificial tooth fracture | 1 | 4 |
| Soft tissue hyperplasia | 1 | 1 |
| Sore spot | 5 | 1 |
| Denture relining | 1 | 1 |
| Resin base fracture | 1 | 1 |
| Total | 18 | 14 |
LIA group: Locator implant attachment group, LBA group: Locator bar attachment group.
The average value of denture satisfaction via Likert Scale
| LIA group | LBA group | ||||
|---|---|---|---|---|---|
| Mean | SD | Mean | SD | ||
| Retention | 3.88 | 0.44 | 3.73 | 0.52 | .786 |
| Esthetics | 4.13 | 0.12 | 4.13 | 0.22 | .094 |
| Mastication | 3.75 | 0.16 | 3.93 | 0.47 | .123 |