Literature DB >> 23189311

Patient preference and satisfaction with implant-supported mandibular overdentures retained with ball or locator attachments: a crossover clinical trial.

Gerald Krennmair1, Rudolf Seemann, Andres Fazekas, Rolf Ewers, Eva Piehslinger.   

Abstract

PURPOSE: To determine patient satisfaction and preference for implant-supported mandibular overdentures (IOD) retained with ball or Locator attachments. In addition, peri-implant conditions and prosthodontic maintenance efforts for the final attachments were evaluated after 1 year of function.
MATERIAL AND METHODS: In this crossover clinical trial, 20 edentulous patients were recruited to receive two mandibular implants in the canine region and were provided with implant-retained mandibular overdentures and new complete maxillary dentures. Implant-retained mandibular overdentures were stabilized with either ball attachments or Locator attachments, in random order. After 3 months of function, the attachments in the existing denture were changed. Questionnaires on satisfaction/complaints with the prostheses were administered at baseline (with the old dentures) and after 3 months of function with each attachment, thus providing for an intraindividual comparison. The decision for the final attachment chosen was based on the patient's preference. For the definitive attachment, peri-implant conditions (peri-implant marginal bone resorption, pocket depth, and Plaque Index, Gingival Index, and Bleeding Index) as well as prosthodontic maintenance efforts and satisfaction score were evaluated after an insertion period of 1 year.
RESULTS: Nineteen (95%) patients completed the study (1 dropout). Patient satisfaction improved significantly (P<.05) from baseline (old dentures) to the new prostheses retained with each of the two attachment types for all domains of satisfaction. However, there were no differences between ball or Locator attachment for any items of satisfaction evaluated and neither attachment had a significant patient preference. No differences for peri-implant parameters or for patient satisfaction were noted between the definitive attachments (ball, n=10; Locator, n=9) after 1 year. Although the overall incidence rate of prosthodontic maintenance did not significantly differ between both retention modalities, the Locator attachment required more postinsertion aftercare (activation of retention) than the ball anchors.

Entities:  

Mesh:

Year:  2012        PMID: 23189311

Source DB:  PubMed          Journal:  Int J Oral Maxillofac Implants        ISSN: 0882-2786            Impact factor:   2.804


  10 in total

1.  Summary of: attitudes of general dental practitioners to the maintenance of Locator retained implant overdentures.

Authors:  Sebastian B M Patzelt
Journal:  Br Dent J       Date:  2014-02       Impact factor: 1.626

2.  Immediate versus Delayed Attachment Incorporation Impact on Prosthetic Aftercare among Mandibular Implant-Supported Overdenture Wearers.

Authors:  Eran Zenziper; Ofir Rosner; Oded Ghelfan; Joseph Nissan; Sigalit Blumer; Gil Ben-Izhack; Moshe Davidovich; Liat Chaushu; Adrian Kahn; Sarit Naishlos
Journal:  J Clin Med       Date:  2022-06-19       Impact factor: 4.964

Review 3.  Unsplinted Attachments and Patient-Reported Outcome Measures (PROMs) in 2-Implant-Retained Mandibular Overdentures: A Systematic Review.

Authors:  Pravinkumar G Patil; Liang Lin Seow; Ting Jing Kweh; Smita Nimbalkar
Journal:  Int J Dent       Date:  2022-05-24

Review 4.  Do ball-type attachment systems for overdenture result in better patient-satisfaction? A systematic review of randomized crossover clinical trial.

Authors:  Cleber Davi Del Rei Daltro Rosa; Rafaella de Souza Leão; Cátia Maria Fonseca Guerra; Eduardo Piza Pellizzer; Bruno Gustavo da Silva Casado; Sandra Lúcia Dantas de Moraes
Journal:  Saudi Dent J       Date:  2021-03-14

5.  Clinical evaluation of mandibular implant overdentures via Locator implant attachment and Locator bar attachment.

Authors:  Yong-Ho Seo; Eun-Bin Bae; Jung-Woo Kim; So-Hyoun Lee; Mi-Jung Yun; Chang-Mo Jeong; Young-Chan Jeon; Jung-Bo Huh
Journal:  J Adv Prosthodont       Date:  2016-08-18       Impact factor: 1.904

6.  Stress distribution patterns of implant supported overdentures-analog versus finite element analysis: A comparative in-vitro study.

Authors:  Soumyadev Satpathy; C L Satish Babu; Shilpa Shetty; Bharat Raj
Journal:  J Indian Prosthodont Soc       Date:  2015 Jul-Sep

7.  Hard and soft-tissue evaluation of bar-clip, ball-socket, and kerator attachments in mandibular implant overdenture treatment: An in vivo study.

Authors:  Nitish Varshney; Sakshi Gupta; Sumit Aggarwal; Shalabh Kumar; M Sadish; Mohsin Khan
Journal:  J Indian Prosthodont Soc       Date:  2019-10-10

Review 8.  Evaluation of Retention, Wear, and Maintenance of Attachment Systems for Single- or Two-Implant-Retained Mandibular Overdentures: A Systematic Review.

Authors:  Raphaël Wakam; Aurélie Benoit; Kwamivi Bernardin Mawussi; Caroline Gorin
Journal:  Materials (Basel)       Date:  2022-03-04       Impact factor: 3.623

9.  Interventions for replacing missing teeth: attachment systems for implant overdentures in edentulous jaws.

Authors:  Alan Gt Payne; Nabeel Hm Alsabeeha; Momen A Atieh; Marco Esposito; Sunyoung Ma; Marwah Anas El-Wegoud
Journal:  Cochrane Database Syst Rev       Date:  2018-10-11

10.  Strains around distally inclined implants retaining mandibular overdentures with Locator attachments: an in vitro study.

Authors:  Moustafa Abdou Elsyad; Fathi Abo Setta; Ahmed Samir Khirallah
Journal:  J Adv Prosthodont       Date:  2016-04-21       Impact factor: 1.904

  10 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.