Literature DB >> 21716970

Mandibular two-implant overdentures: three-year prosthodontic maintenance using the locator attachment system.

Andrew Mackie, Karl Lyons, W Murray Thomson, Alan G T Payne.   

Abstract

Limited clinical research identifies prosthodontic maintenance requirements of mandibular overdentures using the Locator attachment system. Sixty-five edentulous participants received complete maxillary dentures opposing mandibular two-implant overdentures with either Locator nylon (n = 21), Southern plastic (n = 24), or Straumann gold (n = 20) matrices. Prosthodontic maintenance was recorded prospectively for 3 years using defined categories. Over the 3-year period, a mean 3.52 ± 4.8, 2.08 ± 1.9, and 5.5 ± 4.2 maintenance events occurred for Locator, Southern, and Straumann participants, respectively. Prosthodontic success rates of 90% in the Locator nylon group, 88% in the Southern plastic group, and 75% in the Straumann gold group were achieved. Int J Prosthodont 2011;24:328-331.

Entities:  

Mesh:

Year:  2011        PMID: 21716970

Source DB:  PubMed          Journal:  Int J Prosthodont        ISSN: 0893-2174            Impact factor:   1.681


  10 in total

1.  Stud attachments for the mandibular implant-retained overdentures: Prosthetic complications. A literature review.

Authors:  Elie E Daou
Journal:  Saudi Dent J       Date:  2013-02-06

2.  Attitudes of general dental practitioners to the maintenance of Locator retained implant overdentures.

Authors:  J W Vere; S Eliyas; P F Wragg
Journal:  Br Dent J       Date:  2014-02       Impact factor: 1.626

3.  Immediate versus Delayed Attachment Incorporation Impact on Prosthetic Aftercare among Mandibular Implant-Supported Overdenture Wearers.

Authors:  Eran Zenziper; Ofir Rosner; Oded Ghelfan; Joseph Nissan; Sigalit Blumer; Gil Ben-Izhack; Moshe Davidovich; Liat Chaushu; Adrian Kahn; Sarit Naishlos
Journal:  J Clin Med       Date:  2022-06-19       Impact factor: 4.964

Review 4.  Biomaterial aspects: A key factor in the longevity of implant overdenture attachment systems.

Authors:  Elie E Daou
Journal:  J Int Soc Prev Community Dent       Date:  2015 Jul-Aug

5.  Standardizing the evaluation criteria on treatment outcomes of mandibular implant overdentures: a systematic review.

Authors:  Ha-Young Kim; Sang-Wan Shin; Jeong-Yol Lee
Journal:  J Adv Prosthodont       Date:  2014-10-21       Impact factor: 1.904

6.  Clinical evaluation of mandibular implant overdentures via Locator implant attachment and Locator bar attachment.

Authors:  Yong-Ho Seo; Eun-Bin Bae; Jung-Woo Kim; So-Hyoun Lee; Mi-Jung Yun; Chang-Mo Jeong; Young-Chan Jeon; Jung-Bo Huh
Journal:  J Adv Prosthodont       Date:  2016-08-18       Impact factor: 1.904

7.  Implant-prosthetic rehabilitation after radiation treatment in head and neck cancer patients: a case-series report of outcome.

Authors:  Jasna Cotic; Jure Jamsek; Milan Kuhar; Natasa Ihan Hren; Andrej Kansky; Mutlu Özcan; Peter Jevnikar
Journal:  Radiol Oncol       Date:  2016-02-07       Impact factor: 2.991

8.  Microbiological evaluation of LOCATOR® Legacy attachments: A cross-sectional clinical study.

Authors:  Ursina Nagy; Christophe Guédat; Catherine Giannopoulou; Martin Schimmel; Frauke Müller; Murali Srinivasan
Journal:  Clin Exp Dent Res       Date:  2019-07-18

9.  A Comparison of Biomechanical Properties of Implant-Retained Overdenture Based on Precision Attachment Type.

Authors:  Małgorzata Idzior-Haufa; Agnieszka A Pilarska; Wiesław Hędzelek; Piotr Boniecki; Krzysztof Pilarski; Barbara Dorocka-Bobkowska
Journal:  Materials (Basel)       Date:  2021-05-17       Impact factor: 3.623

10.  Clinical performance of LOCATOR® attachments: A retrospective study with 1-8 years of follow-up.

Authors:  Christophe Guédat; Ursina Nagy; Martin Schimmel; Frauke Müller; Murali Srinivasan
Journal:  Clin Exp Dent Res       Date:  2018-07-27
  10 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.