Literature DB >> 23748315

Early-loaded one-stage implants retaining mandibular overdentures by two different mechanisms: 5-year results.

Kivanç Akça1, Yeliz Çavuşoğlu, Elçin Sağirkaya, Murat Cavit Çehreli.   

Abstract

PURPOSE: To compare the biologic and prosthetic outcomes of implants loaded early to retain mandibular overdentures by means of two different attachment systems.
MATERIALS AND METHODS: Patients were screened according to specific inclusion/exclusion criteria and randomly allocated to treatment groups involving two-implant-supported early loaded mandibular overdentures retained by ball attachments or Locator attachments. Marginal bone loss, Plaque Index, peri-implant infection, Bleeding Index, prosthetic complications, and Kaplan-Meier survival estimates of the groups were assessed at the 5-year recall.
RESULTS: Among the 29 patients (58 implants) who completed the study, one implant was lost during healing; all implants survived after prosthesis delivery. Bone loss in the ball attachment group (0.77 ± 0.05 mm) was significantly greater than that in the Locator group (0.59 ± 0.03 mm). The Plaque and Bleeding indices of both groups were comparable, and peri-implant inflammation scores in both groups were zero for all implants. The frequencies of activation of the matrix, replacement of the matrix, and denture reline in the ball attachment group were significantly higher than those observed in the Locator group. While assessments for the absence of any complication showed that the 1- and 3-year Kaplan-Meier survival probabilities of both groups were comparable, when activation of the retainer was excluded, survival probabilities of the ball attachment group were higher.
CONCLUSIONS: The biologic outcomes of early loaded mandibular overdentures retained by ball attachments or Locators were comparable. Although the frequency of prosthetic complications with ball attachments was higher, this did not decrease the survival probability for the treatment.

Entities:  

Mesh:

Substances:

Year:  2013        PMID: 23748315     DOI: 10.11607/jomi.2994

Source DB:  PubMed          Journal:  Int J Oral Maxillofac Implants        ISSN: 0882-2786            Impact factor:   2.804


  3 in total

1.  Clinical evaluation of mandibular implant overdentures via Locator implant attachment and Locator bar attachment.

Authors:  Yong-Ho Seo; Eun-Bin Bae; Jung-Woo Kim; So-Hyoun Lee; Mi-Jung Yun; Chang-Mo Jeong; Young-Chan Jeon; Jung-Bo Huh
Journal:  J Adv Prosthodont       Date:  2016-08-18       Impact factor: 1.904

2.  Stress distribution patterns of implant supported overdentures-analog versus finite element analysis: A comparative in-vitro study.

Authors:  Soumyadev Satpathy; C L Satish Babu; Shilpa Shetty; Bharat Raj
Journal:  J Indian Prosthodont Soc       Date:  2015 Jul-Sep

3.  Interventions for replacing missing teeth: attachment systems for implant overdentures in edentulous jaws.

Authors:  Alan Gt Payne; Nabeel Hm Alsabeeha; Momen A Atieh; Marco Esposito; Sunyoung Ma; Marwah Anas El-Wegoud
Journal:  Cochrane Database Syst Rev       Date:  2018-10-11
  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.