Literature DB >> 8597621

The reliability of pocket probing around screw-type implants.

M Quirynen1, D van Steenberghe, R Jacobs, A Schotte, P Darius.   

Abstract

This study involved 108 patients (age 38-82 years) rehabilitated with overdentures in the lower jaw supported by 2 endosseous screw-shaped implants. At each follow-up visit, the clinical attachment level (PAL) around the implants was assessed with a Merrit-B probe or a constant force electronic probe, Peri-probe, and biannually parallel long-cone radiographs were taken to locate the marginal bone level. These data were used to examine the relationship between bone and attachment level estimations around implants. As a mean, bone level and PAL, for mesial and distal sites, was 0.67 and 0.61 for the Merrit-B probe, and 0.76 and 0.65, respectively for the Peri-probe. The highest correlations were obtained for sites with a healthy gingiva or in absence of intra-bony craters. Duplicate PAL registrations showed a standard deviation for the intra-examiner variability of 2.37 (Peri-probe) or 0.40 mm (Merrit-B probe) with more than 90% of the variation within 0.5 mm. The mean difference in PAL between Merrit-B probe or Peri-probe was 0.05 mm. It was concluded that the clinical attachment level determination is a reliable indicator for bone level around implants with a moderate healthy gingiva.

Entities:  

Mesh:

Substances:

Year:  1991        PMID: 8597621     DOI: 10.1034/j.1600-0501.1991.020405.x

Source DB:  PubMed          Journal:  Clin Oral Implants Res        ISSN: 0905-7161            Impact factor:   5.977


  6 in total

1.  A paralleling technique modification to determine the bone crest level around dental implants.

Authors:  Noelia Fernández-Formoso; B Rilo; M J Mora; I Martínez-Silva; U Santana
Journal:  Dentomaxillofac Radiol       Date:  2011-09       Impact factor: 2.419

2.  Accuracy evaluation of cone beam computed tomography applied to measure peri-implant bone thickness in living patients: an ex vivo and in vivo experiment.

Authors:  Yanhua Lan; Xiaoyuan Huang; Mingxing Fan; Huazhen Yu; Zhijian Xie; Yiqun Zhou
Journal:  Clin Oral Investig       Date:  2022-07-08       Impact factor: 3.606

3.  Osseotite implants inserted into fresh frozen bone grafts.

Authors:  Maurizio Franco; Alessandro Viscione; Leone Rigo; Riccardo Guidi; Giorgio Brunelli; Anna Avantaggiato; Francesco Carinci
Journal:  J Maxillofac Oral Surg       Date:  2009-11-21

4.  Clinical outcome of narrow diameter implants inserted into allografts.

Authors:  Maurizio Franco; Alessandro Viscioni; Leone Rigo; Riccardo Guidi; Ilaria Zollino; Anna Avantaggiato; Francesco Carinci
Journal:  J Appl Oral Sci       Date:  2009 Jul-Aug       Impact factor: 2.698

5.  Clinical evaluation of mandibular implant overdentures via Locator implant attachment and Locator bar attachment.

Authors:  Yong-Ho Seo; Eun-Bin Bae; Jung-Woo Kim; So-Hyoun Lee; Mi-Jung Yun; Chang-Mo Jeong; Young-Chan Jeon; Jung-Bo Huh
Journal:  J Adv Prosthodont       Date:  2016-08-18       Impact factor: 1.904

6.  Roles of a new drug-delivery healing abutment in the prevention and treatment of peri-implant infections: a preliminary study.

Authors:  Shuang Zhang; Min Wang; Tao Jiang; Yi Zhou; Yining Wang
Journal:  RSC Adv       Date:  2018-11-19       Impact factor: 4.036

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.