Literature DB >> 27536648

Results of Primary Total Hip Arthroplasty Using 36 mm Femoral Heads on 1st Generation Highly Cross Linked Polyethylene in Patients 50 Years and Less with Minimum Five Year Follow-up.

Won-Kee Choi1, Myung-Rae Cho1, Hee-Soo Kim1, Jun-Ho Nam1, Seung-Bum Chae1.   

Abstract

PURPOSE: We evaluated the clinical and radiographic midterm results of primary total hip arthroplasty (THA) using a 36 mm diameter femoral head on 1st generation highly cross-linked polyethylene (HXLPE) in patients 50 years and less with minimum five year follow-up.
MATERIALS AND METHODS: We retrospectively reviewed 31 patients (41 hips) aged 50 years and less underwent primary THA with a 36 mm diameter femoral head on HXLPE between 2004 and 2010. Clinical follow-ups included specific measurements like modified Harris hip scores (HHS) and Merle d'Aubigne and Postel score. For radiologic evaluations, together with position of acetabular cup at six weeks later of postoperation, we separately calculated the penentrations of femoral head into polyethylene liners during postoperation and one year later check-ups, and during one year later check-ups and final check-ups.
RESULTS: There were no major complications except for one case of dislocation. Average modified HHS at final follow-up was 88 (81-98), and Merle d'Aubigne and Postel scores were more than 15. Mean acetabular cup inclination and anteversion were 45.81°(36.33°-54.91°) and 13.26°(6.72°-27.71°), respectively. Average femoral head penetration of steady-state wear rate determined using radiographs taken at one-year postoperatively and at latest follow-up was 0.042±0.001 mm/year.
CONCLUSION: Based on minimum 5 years clinical results, we think 36 mm metal head coupling with HXLPE as the good alternate articulation surface when planning THA for patients aged 50 years and less.

Entities:  

Keywords:  36 mm femoral head; Highly cross-linked polyethylene; Total hip arthroplasty

Year:  2016        PMID: 27536648      PMCID: PMC4972889          DOI: 10.5371/hp.2016.28.2.76

Source DB:  PubMed          Journal:  Hip Pelvis        ISSN: 2287-3260


  27 in total

1.  Dislocation rate after hip arthroplasty within the first postoperative year: 36 mm versus 28 mm femoral heads.

Authors:  Alessandro Bistolfi; Maurizio Crova; Federica Rosso; Paolo Titolo; Stefano Ventura; Giuseppe Massazza
Journal:  Hip Int       Date:  2011 Sep-Oct       Impact factor: 2.135

2.  Cementless acetabular components.

Authors:  C A Engh; W L Griffin; C L Marx
Journal:  J Bone Joint Surg Br       Date:  1990-01

3.  Improved cementing techniques and femoral component loosening in young patients with hip arthroplasty. A 12-year radiographic review.

Authors:  R L Barrack; R D Mulroy; W H Harris
Journal:  J Bone Joint Surg Br       Date:  1992-05

4.  Porous-coated hip replacement. The factors governing bone ingrowth, stress shielding, and clinical results.

Authors:  C A Engh; J D Bobyn; A H Glassman
Journal:  J Bone Joint Surg Br       Date:  1987-01

5.  Periprosthetic bone loss in total hip arthroplasty. Polyethylene wear debris and the concept of the effective joint space.

Authors:  T P Schmalzried; M Jasty; W H Harris
Journal:  J Bone Joint Surg Am       Date:  1992-07       Impact factor: 5.284

6.  What are young patients doing after hip reconstruction?

Authors:  Lawrence A Delasotta; Ashwin V Rangavajjula; Manny D Porat; Michael L Frank; Fabio R Orozco; Alvin C Ong
Journal:  J Arthroplasty       Date:  2012-04-17       Impact factor: 4.757

Review 7.  Ceramic femoral head retrieval data.

Authors:  G Willmann
Journal:  Clin Orthop Relat Res       Date:  2000-10       Impact factor: 4.176

8.  Alumina-on-alumina total hip arthroplasty. A five-year minimum follow-up study.

Authors:  Jeong Joon Yoo; Young-Min Kim; Kang Sup Yoon; Kyung-Hoi Koo; Won Seok Song; Hee Joong Kim
Journal:  J Bone Joint Surg Am       Date:  2005-03       Impact factor: 5.284

9.  Ceramic-on-ceramic THA Implants in Patients Younger Than 20 Years.

Authors:  Didier Hannouche; Flore Devriese; Jérôme Delambre; Frédéric Zadegan; Idriss Tourabaly; Laurent Sedel; Sylvie Chevret; Rémy Nizard
Journal:  Clin Orthop Relat Res       Date:  2015-09-04       Impact factor: 4.176

10.  The final follow-up plain radiograph is sufficient for clinical evaluation of polyethylene wear in total hip arthroplasty. A study of validity and reliability.

Authors:  Maiken Stilling; Kristian Larsen; Niels T Andersen; Kjeld Søballe; Søren Kold; Ole Rahbek
Journal:  Acta Orthop       Date:  2010-10       Impact factor: 3.717

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.