Literature DB >> 11039788

Ceramic femoral head retrieval data.

G Willmann1.   

Abstract

In the 1970s it was first realized that the properties of alumina ceramics could be exploited to provide better implants for orthopaedic applications. Applications depend on the fact that ceramics provided wear characteristics suitable for bearing surfaces in total hip replacement. Resultant orthopaedic use had more than 20 years' clinical success. To date more than 2.5 million alumina femoral heads have been implanted. Published reports of fracture rates of the alumina heads range between 0% for ceramics manufactured after 1990 and 13.4% for ceramics manufactured before 1990. These high fracture rates were caused by materials manufactured by companies that are not on the market today. These old aluminas had a low density, had a very coarse microstructure, and were not in compliance with specifications that are valid today. Materials scientists have substantially improved the mechanical strength of alumina. There are three generations of medical grade aluminas. The latest generation is an alumina that is hot isostatic pressed, laser marked, and proof tested. This material has been on the market since 1994. The fracture rates of the most commonly used ceramics have been analyzed by various groups, and are based on .5 million femoral heads to 1.5 million femoral heads. The fracture rate of ceramic Biolox femoral heads are 0.026 % for first generation alumina, 0.014% for second generation alumina, and 0.004% for femoral heads manufactured after 1994. Analyzing the clinical experience of more than 20 years, it can be concluded that all the improvements have produced reliable ceramic femoral heads.

Entities:  

Mesh:

Substances:

Year:  2000        PMID: 11039788     DOI: 10.1097/00003086-200010000-00004

Source DB:  PubMed          Journal:  Clin Orthop Relat Res        ISSN: 0009-921X            Impact factor:   4.176


  52 in total

1.  A squeaky reputation: the problem may be design-dependent.

Authors:  Javad Parvizi; Bahar Adeli; Justin C Wong; Camilo Restrepo; Richard H Rothman
Journal:  Clin Orthop Relat Res       Date:  2011-06       Impact factor: 4.176

2.  Causes of failure of ceramic-on-ceramic and metal-on-metal hip arthroplasties.

Authors:  Manny Porat; Javad Parvizi; Peter F Sharkey; Keith R Berend; Adolph V Lombardi; Robert L Barrack
Journal:  Clin Orthop Relat Res       Date:  2012-02       Impact factor: 4.176

Review 3.  Survival of hard-on-hard bearings in total hip arthroplasty: a systematic review.

Authors:  Michael G Zywiel; Siraj A Sayeed; Aaron J Johnson; Thomas P Schmalzried; Michael A Mont
Journal:  Clin Orthop Relat Res       Date:  2011-06       Impact factor: 4.176

4.  Head material influences survival of a cemented total hip prosthesis in the Norwegian Arthroplasty Register.

Authors:  Thomas Kadar; Eva Dybvik; Geir Hallan; Ove Furnes; Leif Ivar Havelin
Journal:  Clin Orthop Relat Res       Date:  2012-11       Impact factor: 4.176

5.  Ideal femoral head size in total hip arthroplasty balances stability and volumetric wear.

Authors:  Michael B Cross; Denis Nam; David J Mayman
Journal:  HSS J       Date:  2012-09-13

6.  Fractures of a sandwich ceramic liner at ten year follow-up.

Authors:  Anthony Viste; Julien Chouteau; Romain Desmarchelier; Michel-Henri Fessy
Journal:  Int Orthop       Date:  2011-10-20       Impact factor: 3.075

7.  The 2009 Frank Stinchfield Award: "Hip squeaking": a biomechanical study of ceramic-on-ceramic bearing surfaces.

Authors:  Christophe Chevillotte; Robert T Trousdale; Qingshan Chen; Olivier Guyen; Kai-Nan An
Journal:  Clin Orthop Relat Res       Date:  2009-06-19       Impact factor: 4.176

8.  Early dislocation rate in ceramic-on-ceramic total hip arthroplasty.

Authors:  Kenny Mai; Mary E Hardwick; Richard H Walker; Steven N Copp; Kace A Ezzet; Clifford W Colwell
Journal:  HSS J       Date:  2008-02

9.  Incidence of 'squeaking' after ceramic-on-ceramic total hip arthroplasty.

Authors:  Kenny Mai; Christopher Verioti; Kace A Ezzet; Steven N Copp; Richard H Walker; Clifford W Colwell
Journal:  Clin Orthop Relat Res       Date:  2010-02       Impact factor: 4.176

10.  Cementless total hip arthroplasty with ceramic-on-ceramic bearing in patients younger than 45 years with femoral-head osteonecrosis.

Authors:  Young-Hoo Kim; Yoowang Choi; Jun-Shik Kim
Journal:  Int Orthop       Date:  2009-09-26       Impact factor: 3.075

View more