Literature DB >> 27504057

Radiographic and functional evaluation of low profile dorsal versus volar plating for distal radius fractures.

Sanjay Kumar1, A N Khan2, S V Sonanis3.   

Abstract

INTRODUCTION: Fracture of the distal radius is a common clinical problem. Complex fracture requires open reduction and stabilization with plating to restore anatomy. Dorsal plating has advantages of buttressing the fracture better but often complicated with tendon problems as per literature. The rate of complications however, was not compared between the low-profile dorsal and the volar plates.
METHODOLOGY: This was a retrospective study on seventy one patients with dorsally angulated or displaced distal radius fractures, who underwent fixation of fractures with either dorsal or volar locking plate from Jan - Nov 2012. Preoperative radiographs were classified based on Universal and Fernandez classification. Postoperative radiographs were assessed for anatomical restoration of Radial length, radial inclination and volar tilt. Tendon and nerve related complications were assessed and functional evaluation was performed on the basis of PRWE (Patient related wrist evaluation) score.
RESULTS: Both groups were matched for their demographic profile and fracture types (p 0.033). Dorsal plating group had 89% excellent/good restoration and fair in 11%. Volar group had 96% excellent/good restoration and fair in 4%. Statistical analysis was performed with unpaired t test for radiographic parameters. Three patients had tendon related complications in dorsal plating group; two patients in volar group had nerve related complications. Functional outcome with PRWE was comparable between two groups.
CONCLUSION: Results with low profile dorsal plating were comparable to volar plating. Therefore dorsal plating can be used as an alternative method when dorsal buttressing of comminuted fracture is required, especially with concomitant osteoporosis.

Entities:  

Keywords:  Complications; Distal radius fracture; Dorsal plating; Low profile plates; Radiological comparison; Volar plating

Year:  2016        PMID: 27504057      PMCID: PMC4957577          DOI: 10.1016/j.jor.2016.06.017

Source DB:  PubMed          Journal:  J Orthop        ISSN: 0972-978X


  19 in total

1.  Low-profile dorsal plating for dorsally angulated distal radius fractures: an outcomes study.

Authors:  Atul F Kamath; David Zurakowski; Charles S Day
Journal:  J Hand Surg Am       Date:  2006-09       Impact factor: 2.230

2.  Open reduction and internal fixation of intra articular and unstable fractures of the distal radius using the AO distal radius plate.

Authors:  D A Campbell
Journal:  J Hand Surg Br       Date:  2000-12

3.  Treatment of unstable distal radial fractures with the volar locking plating system.

Authors:  Kevin C Chung; Andrew J Watt; Sandra V Kotsis; Zvi Margaliot; Steven C Haase; H Myra Kim
Journal:  J Bone Joint Surg Am       Date:  2006-12       Impact factor: 5.284

4.  Extensor tendon rupture secondary to the AO/ASIF titanium distal radius plate without associated plate failure: a case report.

Authors:  K J Lowry; B J Gainor; J S Hoskins
Journal:  Am J Orthop (Belle Mead NJ)       Date:  2000-10

5.  Volar versus dorsal plating in the management of intra-articular distal radius fractures.

Authors:  David S Ruch; Anastasios Papadonikolakis
Journal:  J Hand Surg Am       Date:  2006-01       Impact factor: 2.230

6.  Colles' fractures. Functional bracing in supination.

Authors:  A Sarmiento; G W Pratt; N C Berry; W F Sinclair
Journal:  J Bone Joint Surg Am       Date:  1975-04       Impact factor: 5.284

7.  Dorsal plating for displaced intra-articular fractures of the distal radius.

Authors:  M Herron; A Faraj; M A C Craigen
Journal:  Injury       Date:  2003-07       Impact factor: 2.586

8.  Functional outcome and complications following two types of dorsal plating for unstable fractures of the distal part of the radius.

Authors:  Tamara D Rozental; Pedro K Beredjiklian; David J Bozentka
Journal:  J Bone Joint Surg Am       Date:  2003-10       Impact factor: 5.284

Review 9.  Fractures of the distal radius: a contemporary approach.

Authors:  S Nijs; P L O Broos
Journal:  Acta Chir Belg       Date:  2004-08       Impact factor: 1.090

10.  Pain and disability reported in the year following a distal radius fracture: a cohort study.

Authors:  Joy C MacDermid; James H Roth; Robert S Richards
Journal:  BMC Musculoskelet Disord       Date:  2003-10-31       Impact factor: 2.362

View more
  6 in total

1.  Contact Pressure between Digital Flexors and Plates for Distal Radius Approaches.

Authors:  Christopher M Jones; Roshan Melvani; Keith T Aziz; Pooyan Abbasi; Kenneth R Means
Journal:  J Wrist Surg       Date:  2019-12-20

2.  Dorsal Plate Osteosynthesis in Simple and Complex Fractures of the Distal Radius: A Radiological Analysis of 166 Cases.

Authors:  Haval Ghafoor; Mathias Haefeli; Regula Steiger; Philipp Honigmann
Journal:  J Wrist Surg       Date:  2021-10-01

3.  Interventions for Distal Radius Fractures: A Meta-analysis of Comparison Studies.

Authors:  Julia Beyer; Emily Wynkoop; Jiayong Liu; Nabil A Ebraheim
Journal:  J Wrist Surg       Date:  2021-02-09

4.  Radial Plate Fixation of Distal Radius Fracture.

Authors:  Sherif Dabash; Eric Potter; Elizabeth Pimentel; Juan Shunia; Amr Abdelgawad; Ahmed M Thabet; Miguel Pirela-Cruz
Journal:  Hand (N Y)       Date:  2018-07-13

5.  Intramedullary Fixation of Distal Radius Fractures Using CAGE-DR Implant.

Authors:  Schneider K Rancy; Stephanie D Malliaris; Eric A Bogner; Scott W Wolfe
Journal:  J Wrist Surg       Date:  2018-09-18

6.  Outcome after treatment of distal radius fractures in the elderly using the IlluminOss® System.

Authors:  Guido W Van Oijen; Paul A Vegt; Tjebbe Hagenaars; Esther M M Van Lieshout; Michael H J Verhofstad
Journal:  Eur J Trauma Emerg Surg       Date:  2020-01-16       Impact factor: 3.693

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.