Literature DB >> 32025355

Contact Pressure between Digital Flexors and Plates for Distal Radius Approaches.

Christopher M Jones1, Roshan Melvani1, Keith T Aziz1, Pooyan Abbasi1, Kenneth R Means1.   

Abstract

Background  Flexor tendon irritation or rupture following open reduction and volar plate fixation of distal radius fractures can cause significant morbidity and necessitate additional surgical intervention. Objectives  To compare the impact of the extended flexor carpi radialis (e-FCR) and standard flexor carpi radialis (FCR) approaches on contact pressures between the flexor tendons and volar distal radius plates. Methods  Eight matched pairs of fresh frozen cadavers had each limb randomized to undergo either the e-FCR or standard FCR approach. After the approach, a locking plate was applied to the volar distal radius more distally than ideally to create a worst-case scenario for the digital flexor tendons. Electronic pressure sensors were secured to the volar aspect of each locking plate. Each wrist was pinned in 20 degrees of extension during testing. Using a computer-controlled stepper motor system attached to the digital flexor and extensor tendons, the digits were taken through 4,000 cycles simulating 12 weeks of active flexion and extension. Results  There were no statistically or clinically significant differences when comparing the contact pressures of the e-FCR approach with the standard FCR approach at any time intervals. The e-FCR had statistically significantly higher radial-sided contact pressures than ulnar-sided contact pressures during early-to-intermediate testing intervals. These differences resolved at late and final testing intervals. Conclusions  When comparing the standard FCR approach with the e-FCR approach, with the wrist in 20 degrees of extension, there is no significant difference in contact pressures that occur between the digital flexor tendons and volar distal radius plates. Clinical Relevance  Further study and technique modifications may eventually lead to better methods of avoiding flexor tendon rupture during the volar plating of distal radius fractures. © Thieme Medical Publishers.

Entities:  

Keywords:  carpal tunnel; distal radius; fracture; tendon rupture; wrist approach

Year:  2019        PMID: 32025355      PMCID: PMC7000249          DOI: 10.1055/s-0039-3402081

Source DB:  PubMed          Journal:  J Wrist Surg        ISSN: 2163-3916


  30 in total

1.  Osteosynthesis of distal radial fractures with a volar locking screw plate system.

Authors:  H Drobetz; E Kutscha-Lissberg
Journal:  Int Orthop       Date:  2002-08-21       Impact factor: 3.075

2.  How placement affects force and contact pressure between a volar plate of the distal radius and the flexor pollicus longus tendon: a biomechanical investigation.

Authors:  A M Matityahu; S N Lapalme; A Seth; M T Marmor; J M Buckley; L L Lattanza
Journal:  J Hand Surg Eur Vol       Date:  2012-07-09

3.  Flexor tendon problems after volar plate fixation of distal radius fractures.

Authors:  Mehdi N Adham; Margaret Porembski; Christine Adham
Journal:  Hand (N Y)       Date:  2009-03-13

4.  Volar locking plate implant prominence and flexor tendon rupture.

Authors:  Maximillian Soong; Brandon E Earp; Gavin Bishop; Albert Leung; Philip Blazar
Journal:  J Bone Joint Surg Am       Date:  2011-01-14       Impact factor: 5.284

Review 5.  Current concepts in volar fixed-angle fixation of unstable distal radius fractures.

Authors:  Jorge L Orbay; Amel Touhami
Journal:  Clin Orthop Relat Res       Date:  2006-04       Impact factor: 4.176

Review 6.  The epidemiology of distal radius fractures.

Authors:  Kate W Nellans; Evan Kowalski; Kevin C Chung
Journal:  Hand Clin       Date:  2012-04-14       Impact factor: 1.907

7.  Radiographic and functional evaluation of low profile dorsal versus volar plating for distal radius fractures.

Authors:  Sanjay Kumar; A N Khan; S V Sonanis
Journal:  J Orthop       Date:  2016-07-19

8.  Functional outcomes for unstable distal radial fractures treated with open reduction and internal fixation or closed reduction and percutaneous fixation. A prospective randomized trial.

Authors:  Tamara D Rozental; Philip E Blazar; Orrin I Franko; Aron T Chacko; Brandon E Earp; Charles S Day
Journal:  J Bone Joint Surg Am       Date:  2009-08       Impact factor: 5.284

9.  Complications following dorsal versus volar plate fixation of distal radius fracture: a meta-analysis.

Authors:  Jie Wei; Tu-Bao Yang; Wei Luo; Jia-Bi Qin; Fan-Jing Kong
Journal:  J Int Med Res       Date:  2013-02-07       Impact factor: 1.671

10.  Comparative outcomes study using the volar locking plating system for distal radius fractures in both young adults and adults older than 60 years.

Authors:  Kevin C Chung; Lee Squitieri; H Myra Kim
Journal:  J Hand Surg Am       Date:  2008 Jul-Aug       Impact factor: 2.230

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.