Haval Ghafoor1, Mathias Haefeli2, Regula Steiger1,3, Philipp Honigmann1,4,5. 1. Hand Surgery, Kantonsspital Baselland, Liestal, Switzerland. 2. Hand Surgery, Kantonsspital Graubünden, Chur, Switzerland. 3. Orthopraxis Lusser, Allschwil, Switzerland. 4. Department of Biomedical Engineering and Physics, Amsterdam Movement Sciences, Amsterdam UMC, University of Amsterdam, Amsterdam, The Netherlands. 5. Department of Biomedical Engineering, Medical Additive Manufacturing Research Group, University of Basel, Allschwil, Switzerland.
Abstract
Background To report the radiologic outcome and rate of complications of open reduction and internal fixation (ORIF) using a dorsal plate fixation of simple and complex distal radius fractures in adult patients. Methods Patients treated with dorsal ORIF of simple and complex distal radius fractures between December 2008 and April 2013 were included in this single-center retrospective study. Type of fracture, radiographic measurements, and complications were documented. Results One-hundred and sixty-six patients/fractures were included. Restoration of radial inclination (22° ± 3°) was achieved in 38%. Radial height (14 ± 1 mm) was least likely to be restored to normal values postoperative in 25%. Normal ulnar variance (0.7 ± 1.5 mm) could be observed in 60% and adequate volar tilt (11° ± 5°) was achieved in 50% at final follow-up. We observed one loss of reduction in an AO type C2 fracture and a total of 15 nonimplant-related minor clinical complications. Conclusion Our radiographic findings after dorsal plating are comparable to those published on volar plating. The changes in radial height and volar tilt could be attributed to projection-related differences in the radiographs and did not signify a loss of reduction in all cases. Clinical Relevance Dorsal plating of distal radius fractures is safe and remains an important approach in the treatment of complex distal radius fractures. Complications in our study were even less compared to those reported in the literature. Type of Study/Level of Evidence This is a Type IV study. Level of Experience of Surgeons The level of experience of surgeons is III-V. The Author(s). This is an open access article published by Thieme under the terms of the Creative Commons Attribution-NonDerivative-NonCommercial License, permitting copying and reproduction so long as the original work is given appropriate credit. Contents may not be used for commercial purposes, or adapted, remixed, transformed or built upon. ( https://creativecommons.org/licenses/by-nc-nd/4.0/ ).
Background To report the radiologic outcome and rate of complications of open reduction and internal fixation (ORIF) using a dorsal plate fixation of simple and complex distal radius fractures in adult patients. Methods Patients treated with dorsal ORIF of simple and complex distal radius fractures between December 2008 and April 2013 were included in this single-center retrospective study. Type of fracture, radiographic measurements, and complications were documented. Results One-hundred and sixty-six patients/fractures were included. Restoration of radial inclination (22° ± 3°) was achieved in 38%. Radial height (14 ± 1 mm) was least likely to be restored to normal values postoperative in 25%. Normal ulnar variance (0.7 ± 1.5 mm) could be observed in 60% and adequate volar tilt (11° ± 5°) was achieved in 50% at final follow-up. We observed one loss of reduction in an AO type C2 fracture and a total of 15 nonimplant-related minor clinical complications. Conclusion Our radiographic findings after dorsal plating are comparable to those published on volar plating. The changes in radial height and volar tilt could be attributed to projection-related differences in the radiographs and did not signify a loss of reduction in all cases. Clinical Relevance Dorsal plating of distal radius fractures is safe and remains an important approach in the treatment of complex distal radius fractures. Complications in our study were even less compared to those reported in the literature. Type of Study/Level of Evidence This is a Type IV study. Level of Experience of Surgeons The level of experience of surgeons is III-V. The Author(s). This is an open access article published by Thieme under the terms of the Creative Commons Attribution-NonDerivative-NonCommercial License, permitting copying and reproduction so long as the original work is given appropriate credit. Contents may not be used for commercial purposes, or adapted, remixed, transformed or built upon. ( https://creativecommons.org/licenses/by-nc-nd/4.0/ ).
Optimal fracture treatment should aim for stable anatomical reduction to allow for early active motion of the wrist to restore functionality.
1
2
3Decision making of the approach is often based on the direction of the dislocated fragments and on the surgeon's preference and experience.
4
5
6
7
8
9
10
Many fracture types of the distal radius can be treated with volar plating, also combined with arthroscopy.
8
9
Despite this trend, there are still fracture patterns which need to be addressed from the dorsal aspect of the distal radius especially in cases of Barton-like fractures, fractures of the dorso-ulnar corner, and complex dorsally comminuted fracture patterns. Improved understanding of biomechanics of the wrist and the role of dislocation of biomechanical units in unstable fracture situations should guide the decision making nowadays.
11Advantages of dorsal plating include better visualization of intra-articular fracture fragments and displacement by arthrotomy and better support against dorsal collapse.
12
The dorsal approach is less favored by surgeons because of the reported higher rate of complications caused by the approach and the implant itself when using older, bulky, and less anatomically shaped implants for dorsal plating. They are associated with a higher rate of complications such as extensor tendon rupture, tenosynovitis, or implant-related soft-tissue irritation.
5
12
13
14
15
16Modern implants, like the one used in our patient cohort, are anatomically shaped, provide a low profile, and allow for placement of angular stable screws.
17
They ensure excellent stability and cause less complications.
18
Wei et al showed in a meta-analysis that there is no significant between-group difference in overall complication rates between patients treated by volar plating versus patients treated by dorsal plating. Volar fixation was associated more often with neuropathy and carpal tunnel syndrome (CTS), whereas the dorsal approach is associated with more tendon irritation.
13In combination with the use of a dorsal retinacular flap, complications of the dorsal approach are nowadays equal to those of volar plating.
17The goal of this study was to compare clinical and radiographical results of patients treated with dorsal plating of distal radius fractures from 2008 until 2013 with accepted radiographic ranges in literature and outcome in patients treated by a volar approach.
Materials and Methods
One-hundred and sixty-six patients with the minimum age of 18 years treated for distal radius fractures by open reduction and internal fixation (ORIF) using a low-profile dorsal frame plate (
Fig. 1
) between December 2008 and April 2013 in our hand surgical unit were included in the study. Correctly projected anterior–posterior (PA)/lateral radiographs pre- and postoperatively, after 4, 8, and 12 to 16 weeks and after removal of implant were mandatory for inclusion (
Fig. 2
). Patients with accompanying fractures of the ulna (other than the ulnar styloid) were excluded from the study. Radiographs with inadequate quality were excluded in consensus with all authors to ensure accurate measurements.
X-rays AP/lat (trauma, 4 weeks postoperatively and after removal of implant). AP, anterior-posterior; lat, lateral.
2.5 TriLock distal radius plates, dorsal (Medartis AG, Basel, Switzerland).X-rays AP/lat (trauma, 4 weeks postoperatively and after removal of implant). AP, anterior-posterior; lat, lateral.Patient selection for the study is shown in
Fig. 3
. Of the 576 eligible distal radius fractures, 35 were conservatively treated, 38 received a dorso-volar ORIF, 172 a volar ORIF, and 7 were treated with other methods. Of the 324 fractures which were treated with a dorsal ORIF, we had to exclude 158 because of insufficient follow-up (e.g., no radiographs in the mentioned intervals, follow-up shorter than 3 months, no removal of implant, insufficient quality of X-rays). One hundred and sixty-six fractures were available for study.
Fig. 3
Eligibility of patients and reasons for exclusion.
Eligibility of patients and reasons for exclusion.In our study, decision making of the chosen approach was based on computed tomography. We use low-radiation and low-cost cone-beam computed tomography (CBCT) in our institution.
19
20One resident (G.H., level of experience III) retrospectively collected clinical data using Polypoint KIS (Erne Consulting AG, Gümlingen, Switzerland). Radiographs were identified in PACS IntelliSpace (Phillips Healthcare, Phillips, Amsterdam, the Netherlands) and exported to IMS Client (Imagic Bildverarbeitung AG, Glattbrugg, Switzerland) for measurement. All data were collected in Microsoft Excel (Microsoft Corporation, Redmond, WA).The anonymized PA and lateral (lat.) radiographs from time of injury, initial postoperative follow-up, after 4 weeks, after 8 weeks, after 3 to 4 months, and after removal of implants were reviewed and measured by the resident and an expert hand surgeon (level V).Fractures were classified according to the Fernandez classification
21
and the revised AO classification
22
(Revised AO/OTA classification, January 2018, AO Foundation, Davos, Switzerland). Radial inclination, radial height, ulnar variance, and volar tilt were measured. Radiographs at the time of injury and after implant removal were additionally measured for articular gap and articular step-off. Results were recorded in millimeters or degrees. Dorsal/volar translation was also measured in the injury films and divided into dorsal/volar groups 1 to 3.Additionally, the occurrence of fractures of the ulnar styloid was also documented and classified with the AO Fracture classification (AO 2U3 A1.1 and A1.2).Methods for obtaining the measurements were according to the principal axis factoring analysis described by Herzberg (
Fig. 4
).
23
Normal reference values and ranges are summarized in
Table 1
.
Fig. 4
Methods of measurements (from left to right) for (
A
) radial inclination, (
B
) radial height, (
C
) ulnar variance, and (
D
) volar tilt.
Table 1
Normal reference values and ranges
Standard values
Radial inclination
22° ± 3°
2425
Radial height
14 ± 1 mm
26
Ulnar variance
0.7 ± 1.5 mm
27
Volar tilt
11° ± 5°
30
Step-off
<2 mm
3233
Gap
<2 mm
3233
Methods of measurements (from left to right) for (
A
) radial inclination, (
B
) radial height, (
C
) ulnar variance, and (
D
) volar tilt.Radial inclination (
Fig. 4A
) was measured on the PA radiograph by creating a line perpendicular the long axis of the radius that touches the ulnar end of the radial plateau and then taking the angle between that line and a line drawn from that ulnar edge of the radius to the tip of the radial styloid. Normal radial inclination was considered to be 22° ± 3°.
24
25Radial height (
Fig. 4B
) was measured by drawing a line through the long axis of the radius and then extending a perpendicular line to it through the ulnar corner of the lunate fossa. Another line parallel to this perpendicular line was drawn through the tip of the radial styloid. The distance between these two parallel lines was measured along the long axis of the radius. We considered normal radial height to be 14 ± 1 mm.
26Ulnar variance (
Fig. 4C
) was also measured on the PA radiograph by creating two perpendicular lines to the long axis of the radius, one extending through the ulnar-most corner of the lunate fossa and one touching the most distal point of the ulnar dome and measuring the distance between those two through the long axis of the radius. Results were recorded in millimeters, whereas negative numbers meant an ulna negative and positive numbers an ulnar positive. Normal ulnar variance was defined as 0.7 ± 1.5 mm.
27Volar tilt (
Fig. 4D
) was measured on the lateral film by again using the long axis of the radius as a reference and creating a perpendicular line to it that touches the most volar point of the articular surface. We then drew another line through that point and the most dorsal point of the articular surface, the angle between those two lines was then documented as volar tilt.
28
29
Normal volar tilt was considered to be 11° ± 5°.
30We additionally defined functional ranges for all measurements apart from radial height according to accepted outcomes in literature: ≤20° dorsal tilt, ≥10° radial inclination, ≤5 mm ulnar variance, and <2 mm step-off.
28
29
31
32Articular congruency was measured by examining the articular surface on the PA or lateral film. Any step-off was measured and recorded as either less than 2 mm or 2 mm and more. This cut-off was chosen based on the work of Knirk and Jupiter
32
that showed the significantly higher occurrence of posttraumatic arthritis of the wrist in patients with an articular step-off greater than 2 mm after operative reduction and fixation and on Lalone et al.
33
The same criteria were used to measure articular gap.The study has been approved by the local ethical committee (EKNZ 2016–00303).
Results
Patient and Fracture Characteristics
The mean age of the 166 patients (131 female, 35 male) was 58.8 years (range 18–84), as seen in
Table 2
. The left hand was affected in 97 and the right in 69 cases, respectively. Seventy cases had a concomitant fracture of the ulnar styloid (49 at the base). We had 79 A, 9 B, and 78 C-type fractures, according to the revised AO classification. Fracture distribution according to the Fernandez classification showed 74 type I, 10 type II, 80 type III, 0 type IV, and 2 type V fractures.
Table 2
Patient demographics
Mean age (y)
Median age (y)
(
n
= 166)
Range (y)
Age (y)
58.83
61
18–84
Sex
Male
35
21.08%
Female
131
78.92%
Injured hand (
n
)
Right
69
41.57%
Left
97
58.43%
Fracture of the ulnar styloid (
n
)
70
42.17%
A1.1
21
12.65%
A1.2
49
29.52%
Radiographic Results
Measurements in preoperative films were not within the range of radiographic norms due to the dislocation of the fracture (
Table 3
).
Table 3
Values for the injury X-ray film
N
Radial Inclination
Radial height
Ulnar variance
Volar tilt
Overall (% [
n
])
166
39.16% (65)
3.61% (6)
45.78% (76)
5.42% (9)
Mean (SD)
17.84° (6.59°)
8.48 mm (3.17 mm)
2.17 mm (2.01 mm)
−18.11° (14.1°)
Minimum to maximum
−0.6° to 45.8°
−0.2 to 19.4 mm
−2.5 to 8 mm
−50.8° to 15.6°
AO class (% [
n
])
A1
0
0% (0)
0% (0)
0% (0)
0% (0)
A2
32
31.25% (10)
0% (0)
40.63% (13)
3.13% (1)
A3
47
36.17% (17)
0% (0)
51.06% (24)
0% (0)
B1
6
50% (3)
0% (0)
50% (3)
50% (3)
B2
3
0% (0)
0% (0)
33.33% (1)
0% (0)
B3
0
0% (0)
0% (0)
0% (0)
0% (0)
C1
30
40% (12)
6.67% (2)
53.33% (16)
10% (3)
C2
25
56% (14)
4% (1)
52% (13)
4% (1)
C3
23
39.13% (9)
13.04% (3)
26.09% (6)
4.35% (1)
Fernandez class (% [
n
])
1
74
36.49% (27)
0% (0)
45.95% (34)
1.35% (1)
2
10
30% (3)
20% (2)
30% (3)
40% (4)
3
80
42.5% (34)
3.8% (3)
47.5% (38)
5% (4)
4
0
0% (0)
0% (0)
0% (0)
0% (0)
5
2
50% (1)
50% (1)
50% (1)
0% (0)
Step-off
Gap
97.59% (162)
91.57% (152)
Abbreviation: SD, standard deviation.
Abbreviation: SD, standard deviation.For the first film postoperatively (range 1–3 days postoperatively), more than 50% of all patients achieved measurements within the norm for radial inclination, ulnar variance, and volar tilt. Only 14% were within norm for radial height (
Table 4
).
Table 4
Values for the intra-operative X-ray film
Measurements for postoperative film
n
Radial inclination
Radial height
Ulnar variance
Volar tilt
Overall (% [
n
])
166
52.41% (87)
13.86% (23)
61.45% (102)
62.05% (103)
Mean (SD)
24.02° (3.29°)
11.22 mm (1.74 mm)
0.22 mm (1.77 mm)
11.98° (6.19°)
Minimum to maximum
14.8° to 31.8°
6.9 to 15.8 mm
−4 to 6.4 mm
−11° to 27°
AO class (% [
n
])
A1
0
0% (0)
0% (0)
0% (0)
0% (0)
A2
32
56.25% (18)
3.13% (1)
46.86% (15)
65.63% (21)
A3
47
57.45% (27)
10.64% (5)
70.21% (33)
63.83% (30)
B1
6
33.33% (2)
50% (3)
50% (3)
50% (3)
B2
3
33.33% (1)
0% (0)
66.67% (2)
100% (3)
B3
0
0% (0)
0% (0)
0% (0)
0% (0)
C1
30
50% (15)
10% (3)
70% (21)
46.67% (14)
C2
25
44% (11)
20% (5)
68% (17)
68% (17)
C3
23
56.52% (13)
26.01% (6)
47.83% (11)
65.22% (15)
Fernandez class (% [
n
])
1
74
52.7% (39)
8.11% (6)
62.16% (46)
62.16% (46)
2
10
40% (4)
60% (6)
70% (7)
100% (10)
3
80
55% (44)
12.5% (10)
60% (48)
57.5% (46)
4
0
0% (0)
0% (0)
0% (0)
0% (0)
5
2
0% (0)
50% (1)
50% (1)
50% (1)
Abbreviation: SD, standard deviation.
Abbreviation: SD, standard deviation.For the first follow-up (4 weeks after surgery), more than 50% reached the radiographic norms for ulnar variance and volar tilt. Only 42% were within norms for radial inclination and 23% for radial height.The means of all radiographic measurements improved from the injury film to the first postoperative follow-up. The measurements remained similar from the postoperative film to the first follow-up (4 weeks after surgery) with the exception of radial inclination and radial height, which showed the most significant difference from postoperative to the first follow-up after 4 weeks (52–42% normal range for radial inclination and 14–23% normal range for radial height).In contrast to this, the percentage of fractures with measurements in the normal ranges decreased in several fracture types (
Tables 3
,
4
,
5
,
6
,
7
), which indicates a loss of reduction postoperatively in some fracture types.
Table 5
Values for the 4 weeks post-op X-ray film
Measurements for first follow-up
n
Radial inclination
Radial height
Ulnar variance
Volar tilt
Overall (% [
n
])
166
42.17% (70)
22.89% (38)
65.66% (109)
57.83% (96)
Mean (SD)
25.23° (3.31°)
11.78 mm (1.69 mm)
0.74 mm (1.71 mm)
12.91° (6.58°)
Minimum to maximum
17.9° to 32.4°
8 to 15.8 mm
−3.5 to 8.2 mm
−16° to 27.8°
AO class (% [
n
])
A1
0
0% (0)
0% (0)
0% (0)
0% (0)
A2
32
37.5% (12)
18.75% (6)
65.63% (21)
53.13% (17)
A3
47
34.04% (16)
17.02% (8)
76.6% (36)
57.45% (27)
B1
6
50% (3)
33.33% (2)
33.33% (2)
50% (3)
B2
3
0% (0)
0% (0)
33.33% (1)
66.67% (2)
B3
0
0% (0)
0% (0)
0% (0)
0% (0)
C1
30
43.33% (13)
26.67% (8)
70% (21)
60% (18)
C2
25
60% (15)
24% (6)
64% (16)
56% (14)
C3
23
47.83% (11)
34.78% (8)
52.17% (12)
65.22% (15)
Fernandez class (% [
n
])
1
74
36.49% (27)
17.57% (13)
70.27% (52)
52.7% (39)
2
10
40% (4)
50% (5)
50% (5)
70% (7)
3
80
47.5% (38)
23.75% (19)
62.5% (50)
61.25% (49)
4
0
0% (0)
0% (0)
0% (0)
0% (0)
5
2
50% (1)
50% (1)
100% (2)
50% (1)
Abbreviation: SD, standard deviation.
Table 6
Values for the 8 weeks post-operative X-ray film
Measurements for second follow-up
N
Radial inclination
Radial height
Ulnar variance
Volar tilt
Overall (% [
n
])
166
43.37% (72)
18.67% (31)
62.05% (103)
57.23% (95)
Mean (SD)
25.6° (3.36°)
11.85 mm (1.75 mm)
0.89 mm (1.78 mm)
13.8° (6.48°)
Minimum to maximum
17.7° to 36.4°
7.2 to 17.2 mm
−3.7 mm to 7.6 mm
−23.5° to 28.4°
AO class (% [
n
])
A1
0
0% (0)
0% (0)
0% (0)
0% (0)
A2
32
37.5% (12)
18.75% (6)
50% (16)
59.38% (19)
A3
47
44.68% (21)
21.28% (10)
70.21% (33)
57.45% (27)
B1
6
16.67% (1)
16.67% (1)
50% (3)
50% (3)
B2
3
33.33% (1)
0% (0)
33.33% (1)
33.33% (1)
B3
0
0% (0)
0% (0)
0% (0)
0% (0)
C1
30
46.67% (14)
13.33% (4)
66.67% (20)
63.33% (19)
C2
25
52% (13)
16% (4)
76% (19)
52% (13)
C3
23
43.48% (10)
26.09% (6)
47.83% (11)
56.52% (13)
Fernandez class (% [
n
])
1
74
44.59% (33)
18.92% (14)
60.81% (45)
55.41% (41)
2
10
30% (3)
40% (4)
30% (3)
50% (5)
3
80
43.75% (35)
15% (12)
67.5% (54)
58.75% (47)
4
0
0%
0% (0)
0% (0)
0% (0)
5
2
50% (1)
50% (1)
50% (1)
100% (2)
Abbreviation: SD, standard deviation.
Table 7
Values for the 1 year postop follow-up X-ray film after removal of implants
Measurements for third follow-up (after implant removal)
N
Radial inclination
Radial height
Ulnar variance
Volar tilt
Overall (% [
n
])
166
37.95% (63)
24.7% (41)
60.24% (100)
50% (83)
Mean (SD)
25.54° (3.09°)
12.17 mm (2.14 mm)
1.23 mm (1.75 mm)
14.06° (6.65°)
Minimum to maximum
14.3° to 32.2°
5.6 to 29.8 mm
−3.2 to 6.4 mm
−19.7° to 27.3°
AO class (% [
n
])
A1
0
0% (0)
0% (0)
0% (0)
0% (0)
A2
32
25% (8)
25% (8)
75% (24)
56.25% (18)
A3
47
36.17% (17)
14.89% (7)
65.96% (31)
48.94% (23)
B1
6
33.33% (2)
33.33% (2)
50% (3)
66.67% (4)
B2
3
0% (0)
0% (0)
33.33% (1)
0% (0)
B3
0
0% (0)
0% (0)
0% (0)
0% (0)
C1
30
43.33% (13)
26.67% (8)
43.33% (13)
53.33% (16)
C2
25
48% (12)
24% (6)
64% (16)
52% (13)
C3
23
47.83% (11)
43.48% (10)
52.17% (12)
39.13% (9)
Fernandez class (% [
n
])
1
74
36.49% (27)
17.57% (13)
71.62% (53)
50% (37)
2
10
30% (3)
40% (4)
40% (4)
50% (5)
3
80
40% (32)
28.75% (23)
52.5% (42)
48.75% (39)
4
0
0% (0)
0% (0)
0% (0)
0% (0)
5
2
50% (1)
50% (1)
50% (1)
100% (2)
Step-off
Gap
99.4% (165)
96.99% (161)
Abbreviation: SD, standard deviation.
Abbreviation: SD, standard deviation.Abbreviation: SD, standard deviation.Abbreviation: SD, standard deviation.If the change in mean was less than the documented standard deviation, we surmised these differences to be due to differing observer measurements or rotation of the radiograph.However, when the change for each parameter from the initial to the final follow-up was greater than the standard deviation in at least three measurements, we reanalyzed the films to evaluate for loss of reduction.
34A total of seven fractures fell into this category. Of these, six had minimal or no loss of reduction, this could be attributed to changes in projection of the radiograph. One C2-fracture showed loss of reduction in the intermediate column and resulted in an ulnocarpal impaction syndrome.We determined the loss of reduction by comparing ulnar variance from the first postoperative radiograph to the final radiograph. If the change to an ulna plus variant was more than the standard deviation, we deemed it as loss of reduction.
34At the final follow-up, following observations can be made: ulnar variance was the most likely parameter to retain reduction in comparison to the postoperative film.Radial height was least likely to be restored to normal ranges of all the radiographic parameters following surgery (
Tables 3
,
4
,
5
,
6
,
7
).Radial inclination showed to be the least likely to maintain reduction within normal ranges from initial follow-up postoperatively to the final follow-up across all fracture types (
Tables 3
,
4
,
5
,
6
,
7
).
Figure 5
shows the distribution of our measurements with the normal radiographic ranges and functional ranges
28
29
31
32
(dotted line) for reference. While most fractures fell into the radiographic norms, some measurements such as radial height and radial inclination show a collective shift outside the norm when comparing the postoperative and second follow-up after 8 weeks.
Fig. 5
Distribution graph of palmar tilt, radial inclination, ulnar variance, and radial height over time 4 points: injury, postoperative, first follow-up (4 weeks), and second follow-up (8 weeks). Radiographic normal range (as seen in
Table 2
) and functional normal range (<20° dorsal angulation, >10° radial inclination, <5 mm ulnar variance).
Distribution graph of palmar tilt, radial inclination, ulnar variance, and radial height over time 4 points: injury, postoperative, first follow-up (4 weeks), and second follow-up (8 weeks). Radiographic normal range (as seen in
Table 2
) and functional normal range (<20° dorsal angulation, >10° radial inclination, <5 mm ulnar variance).
Complications
We recorded a total of 15 clinical complications: none of them were implant-related (categorized by Clavien–Dindo).
35Grade I: Five patients developed a complex regional pain syndrome (CRPS; one type II, four type I) which required extended conservative treatment.Grade III: One patient developed a symptomatic ulnar impaction with posttraumatic shortening of the radius which required corrective osteotomy. Two cases developed a symptomatic CTS (one of which had a simultaneous CRPS) which required surgical decompression. In one patient a ruptured extensor tendon of the index finger was found and sutured during removal of the plate, though it is unclear if the rupture occurred intraoperatively during the approach or postoperatively through irritation by the implant. The patient had not complained about issues in this regard. One patient had iatrogenic lesion of the extensor pollicis longus during osteosynthesis of the fracture, which was sutured and showed no problems postoperatively. Three patients with reduced range of motion showed adhesions of the extensor tendons and required operative tenolysis. Two patients developed posttraumatic and symptomatic radiocarpal arthritis but refused further interventions.
Discussion
Our results show that dorsal plating of distal radius fractures, when performed correctly and by experienced surgeons, provides outcomes on par with the more commonly performed volar plate osteosynthesis when considering radiographic parameters and complication rate.It has been proven that anatomic reduction of distal radius fractures is essential in terms of functional outcome and physiological biomechanics.
32
34
36
Studies have also shown that radial inclination <20°,
37
38
loss of radial height >6 mm,
39
40
volar tilt <5°,
29
and ulnar variance >5 mm
29
41
were associated with poor outcome. A satisfactory functional outcome could nonetheless be achieved despite measurements outside these limits in some cases.
42
43
44The results of our radiographic measurements are comparable to those by Mignemi et al
34
for volar locking plating. Radiographic measurements in the normal range in the final postoperative follow-up were achieved in 38% for radial inclination (43%; Mignemi et al.), 25% for radial height (12%), 60% for ulnar variance (52%), and 50% for volar tilt (48%). For radiocarpal step-off, 99% achieved measurements in a normal range (Mignemi et al, 92%). Radial height was least likely to be restored from first to final follow-up in our study.Only two tendon ruptures were documented in our patient pool: one was of iatrogenic nature during initial surgery and the second (rupture of extensor digitorum II) could not be fully attributed to the plate used.Yu et al compared complication rate between low-profile dorsal plates and volar, and there was no significant difference in tendon irritation or rupture between the two techniques.
45
Several studies attributed the high amount of tendon rupture/irritation and subsequent need for implant removal to one specific implant (Synthes Pi-plate).
14
46
47
Results with low-profile implants have shown better results.
17
42
48
49
50
51Strong points of our study were the large cohort number (i.e., compared with Kamath et al
48
) and the large number of AO/OTA class A fractures, for which a volar approach was more commonly used.Limitations of our study are the single-center and retrospective nature as well as the lack of inclusion of clinical parameters. When measuring the radiographs, patient details were removed but the observers were not blinded to the results of the radiographic evaluation. We also decided not to include clinical observations such as range of motion, as they were not completely documented in the clinical files and we wanted to focus only on radiographic results. By excluding very complex fractures needing additional fixation (K-wires, additional plating, operative treatment of an ulnar fracture), we cannot conclude anything on these types of complex fracture treatment.The modern concept of treatment of simple and complex distal radius fractures focuses on the dislocation direction and consecutive dislocation of the carpus as an additional force which needs to be addressed to avoid loss of reduction and failure of the implant due to exceeding forces.
11
52
53Based on modern concept for the treatment of distal radius fractures in combination with our results, we recommend colleagues treating distal radius fractures to evaluate which approach to take on a case-by-case basis, especially when treating unstable, dorsally displaced fractures with consecutive dorsal dislocation of the carpus and dorso-ulnar corner fragments.
Authors: W Hintringer; R Rosenauer; Ch Pezzei; S Quadlbauer; J Jurkowitsch; T Keuchel; T Hausner; M Leixnering; H Krimmer Journal: Arch Orthop Trauma Surg Date: 2020-03-19 Impact factor: 3.067