Intercomparison of methods for image quality characterization. II. Noise power spectrum.

James T Dobbins1, Ehsan Samei, Nicole T Ranger, Ying Chen.   

Abstract

Second in a two-part series comparing measurement techniques for the assessment of basic image quality metrics in digital radiography, in this paper we focus on the measurement of the image noise power spectrum (NPS). Three methods were considered: (1) a method published by Dobbins et al. [Med. Phys. 22, 1581-1593 (1995)], (2) a method published by Samei et al. [Med. Phys. 30, 608-622 (2003)], and (3) a new method sanctioned by the International Electrotechnical Commission (IEC 62220-1, 2003), developed as part of an international standard for the measurement of detective quantum efficiency. In addition to an overall comparison of the estimated NPS between the three techniques, the following factors were also evaluated for their effect on the measured NPS: horizontal versus vertical directional dependence, the use of beam-limiting apertures, beam spectrum, and computational methods of NPS analysis, including the region-of-interest (ROI) size and the method of ROI normalization. Of these factors, none was found to demonstrate a substantial impact on the amplitude of the NPS estimates (< or = 3.1% relative difference in NPS averaged over frequency, for each factor considered separately). Overall, the three methods agreed to within 1.6% +/- 0.8% when averaged over frequencies > 0.15 mm(-1).

Mesh:

Year:  2006        PMID: 16752581     DOI: 10.1118/1.2188819

Source DB:  PubMed          Journal:  Med Phys        ISSN: 0094-2405            Impact factor:   4.071


  28 in total

1.  Assessment of detective quantum efficiency: intercomparison of a recently introduced international standard with prior methods.

Authors:  Nicole T Ranger; Ehsan Samei; James T Dobbins; Carl E Ravin
Journal:  Radiology       Date:  2007-06       Impact factor: 11.105

2.  Effective DQE (eDQE) and speed of digital radiographic systems: an experimental methodology.

Authors:  Ehsan Samei; Nicole T Ranger; Alistair MacKenzie; Ian D Honey; James T Dobbins; Carl E Ravin
Journal:  Med Phys       Date:  2009-08       Impact factor: 4.071

3.  Accurate MTF measurement in digital radiography using noise response.

Authors:  Andrew Kuhls-Gilcrist; Amit Jain; Daniel R Bednarek; Kenneth R Hoffmann; Stephen Rudin
Journal:  Med Phys       Date:  2010-02       Impact factor: 4.071

4.  Digital magnification mammography with matched incident exposure: physical imaging properties and detectability of simulated microcalcifications.

Authors:  Nobukazu Tanaka; Kentaro Naka; Hiroko Fukushima; Junji Morishita; Fukai Toyofuku; Masafumi Ohki; Yoshiharu Higashida
Journal:  Radiol Phys Technol       Date:  2011-03-18

5.  Structural noise from automatic exposure control device and its relationship to X-ray tube voltage used for calibration of a flat-panel detector system.

Authors:  Masayoshi Mizuta; Hiroyuki Akazawa; Toshifumi Kasai; Shigeru Sanada; Shuji Abe; Shigeki Mitou
Journal:  Radiol Phys Technol       Date:  2011-08-23

6.  Investigation of noise sources for digital radiography systems.

Authors:  Lutfi Ergun; Turan Olgar
Journal:  Radiol Phys Technol       Date:  2016-10-01

7.  Relation between one- and two-dimensional noise power spectra of magnetic resonance images.

Authors:  Yuki Ichinoseki; Yoshio Machida
Journal:  Radiol Phys Technol       Date:  2016-10-03

8.  Basic imaging properties of an indirect flat-panel detector system employing irradiation side sampling (ISS) technology for chest radiography: comparison with a computed radiographic system.

Authors:  Nobukazu Tanaka; Yuki Yano; Hidetake Yabuuchi; Tsutomu Akasaka; Masayuki Sasaki; Masafumi Ohki; Junji Morishita
Journal:  Radiol Phys Technol       Date:  2012-11-10

9.  Investigation of optimum anti-scatter grid selection for digital radiography: physical imaging properties and detectability of low-contrast signals.

Authors:  Nobukazu Tanaka; Kentaro Naka; Aya Saito; Junji Morishita; Fukai Toyofuku; Masafumi Ohki; Yoshiharu Higashida
Journal:  Radiol Phys Technol       Date:  2012-08-08

10.  Correlation of the clinical and physical image quality in chest radiography for average adults with a computed radiography imaging system.

Authors:  C S Moore; T J Wood; A W Beavis; J R Saunderson
Journal:  Br J Radiol       Date:  2013-04-08       Impact factor: 3.039

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.