Literature DB >> 27489515

Comparison of set-up errors by breast size on wing board by portal imaging.

Waseem Raza1, Sushma Agarwal1, Koilpillai Joseph Maria Das1, Sellepolyam Kaliyaperumal Senthil Kumar1, Punita Lal1.   

Abstract

AIM: To quantify and compare setup errors between small and large breast patients undergoing intact breast radiotherapy.
METHODS: 20 patients were inducted. 10 small/moderate size breast in arm I and 10 large breast in arm II. Two orthogonal and one lateral tangent portal images (PIs) were obtained and analyzed for systematic (Σ) and random (σ) errors. Effect of no action level (NAL) was also evaluated retrospectively.
RESULTS: 142 PIs were analyzed. Σ(mm) was 3.2 versus 6.7 (p = 0.41) in the mediolateral (ML) direction, 2.1 versus 2.9 (p = 0.06) in the craniocaudal (CC) and 2.2 versus 3.6 (p = 0.08) in the anteroposterior (AP) direction in small and large breast, respectively. σ(mm) was 3.0, 3.3 and 3.3 for small breast and 4.1, 3.7 and 3.2 for large breast in the ML, CC and AP direction (p = 0.07, 0.86, 0.37), respectively. 3 D Σ(mm) was 2.7 versus 4.2 (p = 0.01) and σ(mm) was 2.5 versus 3.2 (p = 0.14) in arm I and II, respectively. The standard deviation (SD) of variations (mm) in breast contour depicted by central lung distance (CLD) was 5.9 versus 7.4 (p < 0.001), central flash distance (CFD) 6.6 versus 10.5 (p = 0.002), inferior central margin (ICM) 4 versus 4.9 (p < 0.001) in arm I and II, respectively. NAL showed a significant reduction of systematic error in large breast in the mediolateral direction only.
CONCLUSION: Wing board can be used in a busy radiotherapy department for setting up breast patients with a margin of 1.1 cm, 0.76 cm and 0.71 cm for small breasts and 1.96 cm, 1.12 cm and 0.98 cm for large breast in the ML, AP and CC directions, respectively. The large PTV margin in the mediolateral direction in large breast can be reduced using NAL. Further research is needed to optimize positioning of large breasted women.

Entities:  

Keywords:  NAL; Portal image; Setup errors; Small and large breast; Wing board

Year:  2016        PMID: 27489515      PMCID: PMC4949743          DOI: 10.1016/j.rpor.2016.04.001

Source DB:  PubMed          Journal:  Rep Pract Oncol Radiother        ISSN: 1507-1367


  24 in total

1.  Geometrical uncertainties, radiotherapy planning margins, and the ICRU-62 report.

Authors:  Joep C Stroom; Ben J M Heijmen
Journal:  Radiother Oncol       Date:  2002-07       Impact factor: 6.280

2.  The validity of surgical clips as a radiographic surrogate for the lumpectomy cavity in image-guided accelerated partial breast irradiation.

Authors:  Daniel W Weed; Di Yan; Alvaro A Martinez; Frank A Vicini; T J Wilkinson; John Wong
Journal:  Int J Radiat Oncol Biol Phys       Date:  2004-10-01       Impact factor: 7.038

3.  eNAL: an extension of the NAL setup correction protocol for effective use of weekly follow-up measurements.

Authors:  Hans C J de Boer; Ben J M Heijmen
Journal:  Int J Radiat Oncol Biol Phys       Date:  2007-04-01       Impact factor: 7.038

4.  Estimation of optimal matching position for orthogonal kV setup images and minimal setup margins in radiotherapy of whole breast and lymph node areas.

Authors:  Marko Laaksomaa; Mika Kapanen; Tanja Skyttä; Seppo Peltola; Simo Hyödynmaa; Pirkko-Liisa Kellokumpu-Lehtinen
Journal:  Rep Pract Oncol Radiother       Date:  2014-07-15

5.  Postoperative radiotherapy in high-risk postmenopausal breast-cancer patients given adjuvant tamoxifen: Danish Breast Cancer Cooperative Group DBCG 82c randomised trial.

Authors:  M Overgaard; M B Jensen; J Overgaard; P S Hansen; C Rose; M Andersson; C Kamby; M Kjaer; C C Gadeberg; B B Rasmussen; M Blichert-Toft; H T Mouridsen
Journal:  Lancet       Date:  1999-05-15       Impact factor: 79.321

6.  Set-up uncertainties: online correction with X-ray volume imaging.

Authors:  Tejinder Kataria; Ashu Abhishek; Pranav Chadha; Janardhan Nandigam
Journal:  J Cancer Res Ther       Date:  2011 Jan-Mar       Impact factor: 1.805

7.  Postoperative radiotherapy in high-risk premenopausal women with breast cancer who receive adjuvant chemotherapy. Danish Breast Cancer Cooperative Group 82b Trial.

Authors:  M Overgaard; P S Hansen; J Overgaard; C Rose; M Andersson; F Bach; M Kjaer; C C Gadeberg; H T Mouridsen; M B Jensen; K Zedeler
Journal:  N Engl J Med       Date:  1997-10-02       Impact factor: 91.245

8.  Tangential breast irradiation: influence of technique of set-up on transfer errors and reproducibility.

Authors:  C Mitine; A Dutreix; E van der Schueren
Journal:  Radiother Oncol       Date:  1991-12       Impact factor: 6.280

9.  Quality assurance using portal imaging: the accuracy of patient positioning in irradiation of breast cancer.

Authors:  C L Creutzberg; V G Althof; H Huizenga; A G Visser; P C Levendag
Journal:  Int J Radiat Oncol Biol Phys       Date:  1993-02-15       Impact factor: 7.038

10.  Three-dimensional photon dosimetry: a comparison of treatment of the intact breast in the supine and prone position.

Authors:  Katherine L Griem; Pam Fetherston; Marina Kuznetsova; Gregory S Foster; Susan Shott; James Chu
Journal:  Int J Radiat Oncol Biol Phys       Date:  2003-11-01       Impact factor: 7.038

View more
  3 in total

1.  Analysis of local setup errors of sub-regions in cone-beam CT-guided post-mastectomy radiation therapy.

Authors:  Jidan Zhou; Shuai Li; Chengwei Ye; Konglong Shen; An Li; Gang Chen; Xiaoyu Li; Sen Bai; Weifeng Wang; Renming Zhong
Journal:  J Radiat Res       Date:  2020-05-22       Impact factor: 2.724

2.  Setup Error Assessment and Correction in Planar kV Image- Versus Cone Beam CT Image-Guided Radiation Therapy: A Clinical Study of Early Breast Cancer Treated With External Beam Partial Breast Irradiation.

Authors:  Wei Wang; Ting Yu; Min Xu; Qian Shao; Yingjie Zhang; Jianbin Li
Journal:  Technol Cancer Res Treat       Date:  2019 Jan-Dec

3.  Critical Factors of Dose Distribution in Breast Cancer Tomotherapy With Metallic Port Breast Tissue Expander: Image Correction, Delivery Mode, and Volume Impact.

Authors:  Hsing-Yi Lee; Yu-Hsiu Yen; Yu-Lun Tsai; Pei-Chih Tu; Chi-Ming Pu; Chia-Hong Lin; Louis Tak Lui; Suzun Shaw; Ching-Jung Wu; Hsin-Hua Nien
Journal:  Technol Cancer Res Treat       Date:  2022 Jan-Dec
  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.