Literature DB >> 25568414

A comparison of patient-specific and conventional instrumentation for total knee arthroplasty: a multicentre randomised controlled trial.

L Abane1, P Anract1, S Boisgard2, S Descamps2, J P Courpied1, M Hamadouche1.   

Abstract

In this study we randomised 140 patients who were due to undergo primary total knee arthroplasty (TKA) to have the procedure performed using either patient-specific cutting guides (PSCG) or conventional instrumentation (CI). The primary outcome measure was the mechanical axis, as measured at three months on a standing long-leg radiograph by the hip-knee-ankle (HKA) angle. This was undertaken by an independent observer who was blinded to the instrumentation. Secondary outcome measures were component positioning, operating time, Knee Society and Oxford knee scores, blood loss and length of hospital stay. A total of 126 patients (67 in the CI group and 59 in the PSCG group) had complete clinical and radiological data. There were 88 females and 52 males with a mean age of 69.3 years (47 to 84) and a mean BMI of 28.6 kg/m(2) (20.2 to 40.8). The mean HKA angle was 178.9° (172.5 to 183.4) in the CI group and 178.2° (172.4 to 183.4) in the PSCG group (p = 0.34). Outliers were identified in 22 of 67 knees (32.8%) in the CI group and 19 of 59 knees (32.2%) in the PSCG group (p = 0.99). There was no significant difference in the clinical results (p = 0.95 and 0.59, respectively). Operating time, blood loss and length of hospital stay were not significantly reduced (p = 0.09, 0.58 and 0.50, respectively) when using PSCG. The use of PSCG in primary TKA did not reduce the proportion of outliers as measured by post-operative coronal alignment. ©2015 The British Editorial Society of Bone & Joint Surgery.

Entities:  

Keywords:  Knee arthroplasty; alignment; conventional; cutting guides; instrumentation; patient-specific

Mesh:

Year:  2015        PMID: 25568414     DOI: 10.1302/0301-620X.97B1.34440

Source DB:  PubMed          Journal:  Bone Joint J        ISSN: 2049-4394            Impact factor:   5.082


  28 in total

1.  Does final component alignment correlate with alignment of the bone resection surfaces in cemented total knee arthroplasty?

Authors:  Seung-Suk Seo; Chang-Wan Kim; Chang-Rack Lee; Jin-Hyuk Seo; Do-Hun Kim; Ok-Gul Kim; Young-Kyoung Min
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2016-11-08       Impact factor: 4.342

2.  [Total knee arthroplasty with 3D printing technique versus conventional surgery: comparison of the outcomes].

Authors:  Ming Niu; Fei Ma; Ju-Rong Ma; Jun-Wei Li; Xu-Nian Wu; Tong Wang; Yu-Liang Wang
Journal:  Nan Fang Yi Ke Da Xue Xue Bao       Date:  2017-11-20

3.  Mid-term functional outcomes of patient-specific versus conventional instrumentation total knee arthroplasty: a prospective study.

Authors:  Vikaesh Moorthy; Jerry Yongqiang Chen; Ming Han Lincoln Liow; Pak Lin Chin; Shi-Lu Chia; Ngai Nung Lo; Seng Jin Yeo
Journal:  Arch Orthop Trauma Surg       Date:  2021-01-02       Impact factor: 3.067

4.  Comparison of Clinical, Functional, and Radiological Outcomes of Total Knee Arthroplasty Using Conventional and Patient-Specific Instrumentation.

Authors:  Soheil Mehdipour; Mohamad Qoreishi; Ali Keipourfard
Journal:  Arch Bone Jt Surg       Date:  2020-09

5.  Medical 3D Printing Cost-Savings in Orthopedic and Maxillofacial Surgery: Cost Analysis of Operating Room Time Saved with 3D Printed Anatomic Models and Surgical Guides.

Authors:  David H Ballard; Patrick Mills; Richard Duszak; Jeffery A Weisman; Frank J Rybicki; Pamela K Woodard
Journal:  Acad Radiol       Date:  2019-09-18       Impact factor: 3.173

6.  Computerized tomography based "patient specific blocks" improve postoperative mechanical alignment in primary total knee arthroplasty.

Authors:  Raju Vaishya; Vipul Vijay; Vikas P Birla; Amit K Agarwal
Journal:  World J Orthop       Date:  2016-07-18

7.  Outcomes following total knee arthroplasty with CT-based patient-specific instrumentation.

Authors:  Meng Zhu; Jerry Yongqiang Chen; Hwei Chi Chong; Andy Khye Soon Yew; Leon Siang Shen Foo; Shi-Lu Chia; Ngai Nung Lo; Seng Jin Yeo
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2015-09-26       Impact factor: 4.342

8.  A double-blind randomized controlled trial of total knee replacement using patient-specific cutting block instrumentation versus standard instrumentation

Authors:  Thomas R. Turgeon; Brett Cameron; Colin D. Burnell; David R. Hedden; Eric R. Bohm
Journal:  Can J Surg       Date:  2019-12-01       Impact factor: 2.089

Review 9.  Optimizing Intraoperative Blood Management for One-Stage Bilateral Total Knee Arthroplasty.

Authors:  Vasileios Soranoglou; Lazaros A Poultsides; Georgios K Triantafyllopoulos; Ivan De Martino; Stavros G Memtsoudis; Thomas P Sculco
Journal:  HSS J       Date:  2017-12-07

10.  No improvement in reducing outliers in coronal axis alignment with patient-specific instrumentation.

Authors:  Uwe Maus; Carlos J Marques; David Scheunemann; Frank Lampe; Djordje Lazovic; Hagen Hommel; Dennis Vogel; Martin Haunschild; Tilman Pfitzner
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2017-10-25       Impact factor: 4.342

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.