Literature DB >> 27385378

Respiratory motion correction in 4D-PET by simultaneous motion estimation and image reconstruction (SMEIR).

Faraz Kalantari1, Tianfang Li, Mingwu Jin, Jing Wang.   

Abstract

In conventional 4D positron emission tomography (4D-PET), images from different frames are reconstructed individually and aligned by registration methods. Two issues that arise with this approach are as follows: (1) the reconstruction algorithms do not make full use of projection statistics; and (2) the registration between noisy images can result in poor alignment. In this study, we investigated the use of simultaneous motion estimation and image reconstruction (SMEIR) methods for motion estimation/correction in 4D-PET. A modified ordered-subset expectation maximization algorithm coupled with total variation minimization (OSEM-TV) was used to obtain a primary motion-compensated PET (pmc-PET) from all projection data, using Demons derived deformation vector fields (DVFs) as initial motion vectors. A motion model update was performed to obtain an optimal set of DVFs in the pmc-PET and other phases, by matching the forward projection of the deformed pmc-PET with measured projections from other phases. The OSEM-TV image reconstruction was repeated using updated DVFs, and new DVFs were estimated based on updated images. A 4D-XCAT phantom with typical FDG biodistribution was generated to evaluate the performance of the SMEIR algorithm in lung and liver tumors with different contrasts and different diameters (10-40 mm). The image quality of the 4D-PET was greatly improved by the SMEIR algorithm. When all projections were used to reconstruct 3D-PET without motion compensation, motion blurring artifacts were present, leading up to 150% tumor size overestimation and significant quantitative errors, including 50% underestimation of tumor contrast and 59% underestimation of tumor uptake. Errors were reduced to less than 10% in most images by using the SMEIR algorithm, showing its potential in motion estimation/correction in 4D-PET.

Entities:  

Mesh:

Year:  2016        PMID: 27385378      PMCID: PMC4972500          DOI: 10.1088/0031-9155/61/15/5639

Source DB:  PubMed          Journal:  Phys Med Biol        ISSN: 0031-9155            Impact factor:   3.609


  50 in total

1.  Reduction of respiratory motion artifacts in PET imaging of lung cancer by respiratory correlated dynamic PET: methodology and comparison with respiratory gated PET.

Authors:  Sadek A Nehmeh; Yusuf E Erdi; Kenneth E Rosenzweig; Heiko Schoder; Steve M Larson; Olivia D Squire; John L Humm
Journal:  J Nucl Med       Date:  2003-10       Impact factor: 10.057

2.  Joint reconstruction of image and motion in gated positron emission tomography.

Authors:  Moritz Blume; Axel Martinez-Möller; Andreas Keil; Nassir Navab; Magdalena Rafecas
Journal:  IEEE Trans Med Imaging       Date:  2010-06-17       Impact factor: 10.048

3.  Model-based image reconstruction for four-dimensional PET.

Authors:  Tianfang Li; Brian Thorndyke; Eduard Schreibmann; Yong Yang; Lei Xing
Journal:  Med Phys       Date:  2006-05       Impact factor: 4.071

4.  Respiratory motion correction for PET oncology applications using affine transformation of list mode data.

Authors:  F Lamare; T Cresson; J Savean; C Cheze Le Rest; A J Reader; D Visvikis
Journal:  Phys Med Biol       Date:  2006-12-12       Impact factor: 3.609

5.  Respiratory-induced errors in tumor quantification and delineation in CT attenuation-corrected PET images: effects of tumor size, tumor location, and respiratory trace: a simulation study using the 4D XCAT phantom.

Authors:  Parham Geramifar; Mojtaba Shamsaie Zafarghandi; Pardis Ghafarian; Arman Rahmim; Mohammad Reza Ay
Journal:  Mol Imaging Biol       Date:  2013-12       Impact factor: 3.488

6.  Impact of respiratory motion correction and spatial resolution on lesion detection in PET: a simulation study based on real MR dynamic data.

Authors:  Irene Polycarpou; Charalampos Tsoumpas; Andrew P King; Paul K Marsden
Journal:  Phys Med Biol       Date:  2014-02-07       Impact factor: 3.609

7.  Automatic volume delineation in oncological PET. Evaluation of a dedicated software tool and comparison with manual delineation in clinical data sets.

Authors:  F Hofheinz; C Pötzsch; L Oehme; B Beuthien-Baumann; J Steinbach; J Kotzerke; J van den Hoff
Journal:  Nuklearmedizin       Date:  2011-10-26       Impact factor: 1.379

8.  Precise and real-time measurement of 3D tumor motion in lung due to breathing and heartbeat, measured during radiotherapy.

Authors:  Yvette Seppenwoolde; Hiroki Shirato; Kei Kitamura; Shinichi Shimizu; Marcel van Herk; Joos V Lebesque; Kazuo Miyasaka
Journal:  Int J Radiat Oncol Biol Phys       Date:  2002-07-15       Impact factor: 7.038

Review 9.  Noninvasive staging of non-small cell lung cancer: a review of the current evidence.

Authors:  Eric M Toloza; Linda Harpole; Douglas C McCrory
Journal:  Chest       Date:  2003-01       Impact factor: 9.410

10.  Effective and organ doses using helical 4DCT for thoracic and abdominal therapies.

Authors:  Yuka Matsuzaki; Keisuke Fujii; Motoki Kumagai; Ichiro Tsuruoka; Shinichiro Mori
Journal:  J Radiat Res       Date:  2013-04-19       Impact factor: 2.724

View more
  7 in total

1.  Comparison of the clinical performance of upper abdominal PET/DCE-MRI with and without concurrent respiratory motion correction (MoCo).

Authors:  Onofrio A Catalano; Lale Umutlu; Niccolo Fuin; Matthew Louis Hibert; Michele Scipioni; Stefano Pedemonte; Mark Vangel; Andreea Maria Catana; Ken Herrmann; Felix Nensa; David Groshar; Umar Mahmood; Bruce R Rosen; Ciprian Catana
Journal:  Eur J Nucl Med Mol Imaging       Date:  2018-07-11       Impact factor: 9.236

2.  Attenuation correction in 4D-PET using a single-phase attenuation map and rigidity-adaptive deformable registration.

Authors:  Faraz Kalantari; Jing Wang
Journal:  Med Phys       Date:  2017-02-03       Impact factor: 4.071

3.  Quantitative 4D-PET reconstruction for small animal using SMEIR-reconstructed 4D-CBCT.

Authors:  Yuncheng Zhong; Faraz Kalantari; You Zhang; Yiping Shao; Jing Wang
Journal:  IEEE Trans Radiat Plasma Med Sci       Date:  2018-03-09

4.  Motion correction of respiratory-gated PET images using deep learning based image registration framework.

Authors:  Tiantian Li; Mengxi Zhang; Wenyuan Qi; Evren Asma; Jinyi Qi
Journal:  Phys Med Biol       Date:  2020-07-30       Impact factor: 3.609

5.  Multi-Tracer Guided PET Image Reconstruction.

Authors:  Sam Ellis; Andrew Mallia; Colm J McGinnity; Gary J R Cook; Andrew J Reader
Journal:  IEEE Trans Radiat Plasma Med Sci       Date:  2018-07-23

6.  New Data-Driven Gated PET/CT Free of Misregistration Artifacts.

Authors:  Tinsu Pan; Yang Lu; M Allan Thomas; Zhongxing Liao; Dershan Luo
Journal:  Int J Radiat Oncol Biol Phys       Date:  2020-11-10       Impact factor: 7.038

7.  General simultaneous motion estimation and image reconstruction (G-SMEIR).

Authors:  Shiwei Zhou; Yujie Chi; Jing Wang; Mingwu Jin
Journal:  Biomed Phys Eng Express       Date:  2021-07-29
  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.