Histological evaluation of a chronically-implanted electrocorticographic electrode grid in a non-human primate.

Alan D Degenhart1, James Eles, Richard Dum, Jessica L Mischel, Ivan Smalianchuk, Bridget Endler, Robin C Ashmore, Elizabeth C Tyler-Kabara, Nicholas G Hatsopoulos, Wei Wang, Aaron P Batista, X Tracy Cui.   

Abstract

OBJECTIVE: Electrocorticography (ECoG), used as a neural recording modality for brain-machine interfaces (BMIs), potentially allows for field potentials to be recorded from the surface of the cerebral cortex for long durations without suffering the host-tissue reaction to the extent that it is common with intracortical microelectrodes. Though the stability of signals obtained from chronically implanted ECoG electrodes has begun receiving attention, to date little work has characterized the effects of long-term implantation of ECoG electrodes on underlying cortical tissue. APPROACH: We implanted and recorded from a high-density ECoG electrode grid subdurally over cortical motor areas of a Rhesus macaque for 666 d. MAIN
RESULTS: Histological analysis revealed minimal damage to the cortex underneath the implant, though the grid itself was encapsulated in collagenous tissue. We observed macrophages and foreign body giant cells at the tissue-array interface, indicative of a stereotypical foreign body response. Despite this encapsulation, cortical modulation during reaching movements was observed more than 18 months post-implantation. SIGNIFICANCE: These results suggest that ECoG may provide a means by which stable chronic cortical recordings can be obtained with comparatively little tissue damage, facilitating the development of clinically viable BMI systems.

Entities:  

Mesh:

Substances:

Year:  2016        PMID: 27351722      PMCID: PMC4993459          DOI: 10.1088/1741-2560/13/4/046019

Source DB:  PubMed          Journal:  J Neural Eng        ISSN: 1741-2552            Impact factor:   5.379


  104 in total

1.  3-dimensional imaging of collagen using second harmonic generation.

Authors:  Guy Cox; Eleanor Kable; Allan Jones; Ian Fraser; Frank Manconi; Mark D Gorrell
Journal:  J Struct Biol       Date:  2003-01       Impact factor: 2.867

2.  The brain tissue response to implanted silicon microelectrode arrays is increased when the device is tethered to the skull.

Authors:  Roy Biran; Dave C Martin; Patrick A Tresco
Journal:  J Biomed Mater Res A       Date:  2007-07       Impact factor: 4.396

3.  Effects of insertion conditions on tissue strain and vascular damage during neuroprosthetic device insertion.

Authors:  C S Bjornsson; S J Oh; Y A Al-Kofahi; Y J Lim; K L Smith; J N Turner; S De; B Roysam; W Shain; S J Kim
Journal:  J Neural Eng       Date:  2006-06-21       Impact factor: 5.379

4.  An alginate hydrogel dura mater replacement for use with intracortical electrodes.

Authors:  Elizabeth A Nunamaker; Daryl R Kipke
Journal:  J Biomed Mater Res B Appl Biomater       Date:  2010-11       Impact factor: 3.368

5.  Cerebral astrocyte response to micromachined silicon implants.

Authors:  J N Turner; W Shain; D H Szarowski; M Andersen; S Martins; M Isaacson; H Craighead
Journal:  Exp Neurol       Date:  1999-03       Impact factor: 5.330

6.  Dissolvable films of silk fibroin for ultrathin conformal bio-integrated electronics.

Authors:  Dae-Hyeong Kim; Jonathan Viventi; Jason J Amsden; Jianliang Xiao; Leif Vigeland; Yun-Soung Kim; Justin A Blanco; Bruce Panilaitis; Eric S Frechette; Diego Contreras; David L Kaplan; Fiorenzo G Omenetto; Yonggang Huang; Keh-Chih Hwang; Mitchell R Zakin; Brian Litt; John A Rogers
Journal:  Nat Mater       Date:  2010-04-18       Impact factor: 43.841

7.  Using the electrocorticographic speech network to control a brain-computer interface in humans.

Authors:  Eric C Leuthardt; Charles Gaona; Mohit Sharma; Nicholas Szrama; Jarod Roland; Zac Freudenberg; Jamie Solis; Jonathan Breshears; Gerwin Schalk
Journal:  J Neural Eng       Date:  2011-04-07       Impact factor: 5.379

8.  The effect of micro-ECoG substrate footprint on the meningeal tissue response.

Authors:  Amelia A Schendel; Michael W Nonte; Corinne Vokoun; Thomas J Richner; Sarah K Brodnick; Farid Atry; Seth Frye; Paige Bostrom; Ramin Pashaie; Sanitta Thongpang; Kevin W Eliceiri; Justin C Williams
Journal:  J Neural Eng       Date:  2014-06-18       Impact factor: 5.379

9.  Characterization of flexible ECoG electrode arrays for chronic recording in awake rats.

Authors:  John D Yeager; Derrick J Phillips; David M Rector; David F Bahr
Journal:  J Neurosci Methods       Date:  2008-07-03       Impact factor: 2.390

10.  Reconstructing speech from human auditory cortex.

Authors:  Brian N Pasley; Stephen V David; Nima Mesgarani; Adeen Flinker; Shihab A Shamma; Nathan E Crone; Robert T Knight; Edward F Chang
Journal:  PLoS Biol       Date:  2012-01-31       Impact factor: 8.029

View more
  26 in total

1.  A Materials Roadmap to Functional Neural Interface Design.

Authors:  Steven M Wellman; James R Eles; Kip A Ludwig; John P Seymour; Nicholas J Michelson; William E McFadden; Alberto L Vazquez; Takashi D Y Kozai
Journal:  Adv Funct Mater       Date:  2017-07-19       Impact factor: 18.808

2.  Quantitative simulation of extracellular single unit recording from the surface of cortex.

Authors:  Mackenna Hill; Estefania Rios; Shyam Kumar Sudhakar; Douglas H Roossien; Ciara Caldwell; Dawen Cai; Omar J Ahmed; Scott F Lempka; Cynthia A Chestek
Journal:  J Neural Eng       Date:  2018-06-20       Impact factor: 5.379

Review 3.  The Potential for a Speech Brain-Computer Interface Using Chronic Electrocorticography.

Authors:  Qinwan Rabbani; Griffin Milsap; Nathan E Crone
Journal:  Neurotherapeutics       Date:  2019-01       Impact factor: 7.620

4.  Unique electrophysiological and impedance signatures between encapsulation types: An analysis of biological Utah array failure and benefit of a biomimetic coating in a rat model.

Authors:  Patrick A Cody; James R Eles; Carl F Lagenaur; Takashi D Y Kozai; X Tracy Cui
Journal:  Biomaterials       Date:  2018-02-01       Impact factor: 12.479

5.  Remapping cortical modulation for electrocorticographic brain-computer interfaces: a somatotopy-based approach in individuals with upper-limb paralysis.

Authors:  Alan D Degenhart; Shivayogi V Hiremath; Ying Yang; Stephen Foldes; Jennifer L Collinger; Michael Boninger; Elizabeth C Tyler-Kabara; Wei Wang
Journal:  J Neural Eng       Date:  2018-04       Impact factor: 5.379

6.  Complications of epidural spinal stimulation: lessons from the past and alternatives for the future.

Authors:  Giuliano Taccola; Sean Barber; Phillip J Horner; Humberto A Cerrel Bazo; Dimitry Sayenko
Journal:  Spinal Cord       Date:  2020-06-23       Impact factor: 2.772

7.  Meningeal inflammatory response and fibrous tissue remodeling around intracortical implants: An in vivo two-photon imaging study.

Authors:  J R Eles; A L Vazquez; T D Y Kozai; X T Cui
Journal:  Biomaterials       Date:  2018-12-31       Impact factor: 12.479

8.  In vivo imaging of neuronal calcium during electrode implantation: Spatial and temporal mapping of damage and recovery.

Authors:  James R Eles; Alberto L Vazquez; Takashi D Y Kozai; X Tracy Cui
Journal:  Biomaterials       Date:  2018-05-07       Impact factor: 12.479

9.  Neuroadhesive L1 coating attenuates acute microglial attachment to neural electrodes as revealed by live two-photon microscopy.

Authors:  James R Eles; Alberto L Vazquez; Noah R Snyder; Carl Lagenaur; Matthew C Murphy; Takashi D Y Kozai; X Tracy Cui
Journal:  Biomaterials       Date:  2016-11-01       Impact factor: 12.479

10.  Intracranial EEG fluctuates over months after implanting electrodes in human brain.

Authors:  Hoameng Ung; Steven N Baldassano; Hank Bink; Abba M Krieger; Shawniqua Williams; Flavia Vitale; Chengyuan Wu; Dean Freestone; Ewan Nurse; Kent Leyde; Kathryn A Davis; Mark Cook; Brian Litt
Journal:  J Neural Eng       Date:  2017-09-01       Impact factor: 5.379

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.