Literature DB >> 16921203

Effects of insertion conditions on tissue strain and vascular damage during neuroprosthetic device insertion.

C S Bjornsson1, S J Oh, Y A Al-Kofahi, Y J Lim, K L Smith, J N Turner, S De, B Roysam, W Shain, S J Kim.   

Abstract

Long-term integration of neuroprosthetic devices is challenged by reactive responses that compromise the brain-device interface. The contribution of physical insertion parameters to immediate damage is not well described. We have developed an ex vivo preparation to capture real-time images of tissue deformation during device insertion using thick tissue slices from rat brains prepared with fluorescently labeled vasculature. Qualitative and quantitative assessments of damage were made for insertions using devices with different tip shapes inserted at different speeds. Direct damage to the vasculature included severing, rupturing and dragging, and was often observed several hundred micrometers from the insertion site. Slower insertions generally resulted in more vascular damage. Cortical surface features greatly affected insertion success; insertions attempted through pial blood vessels resulted in severe tissue compression. Automated image analysis techniques were developed to quantify tissue deformation and calculate mean effective strain. Quantitative measures demonstrated that, within the range of experimental conditions studied, faster insertion of sharp devices resulted in lower mean effective strain. Variability within each insertion condition indicates that multiple biological factors may influence insertion success. Multiple biological factors may contribute to tissue distortion, thus a wide variability was observed among insertions made under the same conditions.

Entities:  

Mesh:

Year:  2006        PMID: 16921203     DOI: 10.1088/1741-2560/3/3/002

Source DB:  PubMed          Journal:  J Neural Eng        ISSN: 1741-2552            Impact factor:   5.379


  108 in total

1.  Blast-induced tinnitus and hearing loss in rats: behavioral and imaging assays.

Authors:  Johnny C Mao; Edward Pace; Paige Pierozynski; Zhifeng Kou; Yimin Shen; Pamela VandeVord; E Mark Haacke; Xueguo Zhang; Jinsheng Zhang
Journal:  J Neurotrauma       Date:  2011-11-22       Impact factor: 5.269

2.  Influence of needle insertion speed on backflow for convection-enhanced delivery.

Authors:  Fernando Casanova; Paul R Carney; Malisa Sarntinoranont
Journal:  J Biomech Eng       Date:  2012-04       Impact factor: 2.097

3.  Reduction of neurovascular damage resulting from microelectrode insertion into the cerebral cortex using in vivo two-photon mapping.

Authors:  T D Y Kozai; T C Marzullo; F Hooi; N B Langhals; A K Majewska; E B Brown; D R Kipke
Journal:  J Neural Eng       Date:  2010-07-19       Impact factor: 5.379

4.  In vivo evaluation of needle force and friction stress during insertion at varying insertion speed into the brain.

Authors:  Fernando Casanova; Paul R Carney; Malisa Sarntinoranont
Journal:  J Neurosci Methods       Date:  2014-08-20       Impact factor: 2.390

Review 5.  Advanced neurotechnologies for chronic neural interfaces: new horizons and clinical opportunities.

Authors:  Daryl R Kipke; William Shain; György Buzsáki; E Fetz; Jaimie M Henderson; Jamille F Hetke; Gerwin Schalk
Journal:  J Neurosci       Date:  2008-11-12       Impact factor: 6.167

6.  Implantable microelectrode arrays for simultaneous electrophysiological and neurochemical recordings.

Authors:  Matthew D Johnson; Robert K Franklin; Matthew D Gibson; Richard B Brown; Daryl R Kipke
Journal:  J Neurosci Methods       Date:  2008-07-23       Impact factor: 2.390

7.  Histological evaluation of a chronically-implanted electrocorticographic electrode grid in a non-human primate.

Authors:  Alan D Degenhart; James Eles; Richard Dum; Jessica L Mischel; Ivan Smalianchuk; Bridget Endler; Robin C Ashmore; Elizabeth C Tyler-Kabara; Nicholas G Hatsopoulos; Wei Wang; Aaron P Batista; X Tracy Cui
Journal:  J Neural Eng       Date:  2016-06-28       Impact factor: 5.379

8.  Inhibition of the cluster of differentiation 14 innate immunity pathway with IAXO-101 improves chronic microelectrode performance.

Authors:  John K Hermann; Madhumitha Ravikumar; Andrew J Shoffstall; Evon S Ereifej; Kyle M Kovach; Jeremy Chang; Arielle Soffer; Chun Wong; Vishnupriya Srivastava; Patrick Smith; Grace Protasiewicz; Jingle Jiang; Stephen M Selkirk; Robert H Miller; Steven Sidik; Nicholas P Ziats; Dawn M Taylor; Jeffrey R Capadona
Journal:  J Neural Eng       Date:  2018-04       Impact factor: 5.379

9.  Failure mode analysis of silicon-based intracortical microelectrode arrays in non-human primates.

Authors:  James C Barrese; Naveen Rao; Kaivon Paroo; Corey Triebwasser; Carlos Vargas-Irwin; Lachlan Franquemont; John P Donoghue
Journal:  J Neural Eng       Date:  2013-11-12       Impact factor: 5.379

10.  Long-term changes in the material properties of brain tissue at the implant-tissue interface.

Authors:  Arati Sridharan; Subramaniam D Rajan; Jit Muthuswamy
Journal:  J Neural Eng       Date:  2013-10-08       Impact factor: 5.379

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.