Literature DB >> 20878928

An alginate hydrogel dura mater replacement for use with intracortical electrodes.

Elizabeth A Nunamaker1, Daryl R Kipke.   

Abstract

The collagenous dura mater requires a secure closure following implantation of neural prosthetic devices to avoid complications due to cerebrospinal fluid leakage and infections. Alginate was previously suggested for use as a dural sealant. The liquid application and controllable gelling conditions enable alginate to conform to the unique geometries of a neural prosthetic device and the surrounding dura mater to create a barrier with the external environment. In this study, we evaluated the use of alginate as a method to securely reclose a dural defect and seal around an untethered microscale neural probe in the rabbit model. After 3 days and 3 weeks, the sealing strength of alginate remained eight times greater than normal rabbit intracranial pressure and similar in both the presence and absence of a penetrating neural probe. For time points up to 3 months, there was no significant difference in dura mater fibrosis or thickness between alginate and controls. Application of alginate to a dural defect results in a watertight seal that remains intact while the dura mater reforms. These findings indicate that alginate is an effective tool for sealing around microscale neural probes and suggests broader application as a sealant for larger neural prosthetic devices.
© 2010 Wiley Periodicals, Inc.

Entities:  

Mesh:

Substances:

Year:  2010        PMID: 20878928     DOI: 10.1002/jbm.b.31733

Source DB:  PubMed          Journal:  J Biomed Mater Res B Appl Biomater        ISSN: 1552-4973            Impact factor:   3.368


  10 in total

1.  Histological evaluation of a chronically-implanted electrocorticographic electrode grid in a non-human primate.

Authors:  Alan D Degenhart; James Eles; Richard Dum; Jessica L Mischel; Ivan Smalianchuk; Bridget Endler; Robin C Ashmore; Elizabeth C Tyler-Kabara; Nicholas G Hatsopoulos; Wei Wang; Aaron P Batista; X Tracy Cui
Journal:  J Neural Eng       Date:  2016-06-28       Impact factor: 5.379

2.  Reduced cell attachment to poly(2-hydroxyethyl methacrylate)-coated ventricular catheters in vitro.

Authors:  Brian W Hanak; Chia-Yun Hsieh; William Donaldson; Samuel R Browd; Kenneth K S Lau; William Shain
Journal:  J Biomed Mater Res B Appl Biomater       Date:  2017-06-20       Impact factor: 3.368

3.  Insertion of linear 8.4 μm diameter 16 channel carbon fiber electrode arrays for single unit recordings.

Authors:  Paras R Patel; Kyounghwan Na; Huanan Zhang; Takashi D Y Kozai; Nicholas A Kotov; Euisik Yoon; Cynthia A Chestek
Journal:  J Neural Eng       Date:  2015-06-02       Impact factor: 5.379

4.  Chronic in vivo stability assessment of carbon fiber microelectrode arrays.

Authors:  Paras R Patel; Huanan Zhang; Matthew T Robbins; Justin B Nofar; Shaun P Marshall; Michael J Kobylarek; Takashi D Y Kozai; Nicholas A Kotov; Cynthia A Chestek
Journal:  J Neural Eng       Date:  2016-10-05       Impact factor: 5.379

5.  Meningeal inflammatory response and fibrous tissue remodeling around intracortical implants: An in vivo two-photon imaging study.

Authors:  J R Eles; A L Vazquez; T D Y Kozai; X T Cui
Journal:  Biomaterials       Date:  2018-12-31       Impact factor: 12.479

6.  Photo-Crosslinked Hyaluronic Acid/Carboxymethyl Cellulose Composite Hydrogel as a Dural Substitute to Prevent Post-Surgical Adhesion.

Authors:  Yin-Cheng Huang; Zhuo-Hao Liu; Chang-Yi Kuo; Jyh-Ping Chen
Journal:  Int J Mol Sci       Date:  2022-05-31       Impact factor: 6.208

7.  Sub-meninges implantation reduces immune response to neural implants.

Authors:  Neil T Markwardt; Jodi Stokol; Robert L Rennaker
Journal:  J Neurosci Methods       Date:  2013-01-28       Impact factor: 2.390

8.  Two-photon imaging of chronically implanted neural electrodes: Sealing methods and new insights.

Authors:  Takashi D Y Kozai; James R Eles; Alberto L Vazquez; X Tracy Cui
Journal:  J Neurosci Methods       Date:  2015-10-23       Impact factor: 2.390

9.  Minimal Tissue Reaction after Chronic Subdural Electrode Implantation for Fully Implantable Brain-Machine Interfaces.

Authors:  Tianfang Yan; Seiji Kameda; Katsuyoshi Suzuki; Taro Kaiju; Masato Inoue; Takafumi Suzuki; Masayuki Hirata
Journal:  Sensors (Basel)       Date:  2020-12-29       Impact factor: 3.576

10.  Fabrication of three-dimensional hydrogel scaffolds for modeling shunt failure by tissue obstruction in hydrocephalus.

Authors:  Carolyn Harris; Kelsie Pearson; Kristen Hadley; Shanshan Zhu; Samuel Browd; Brian W Hanak; William Shain
Journal:  Fluids Barriers CNS       Date:  2015-11-14
  10 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.