Literature DB >> 27315122

His Bundle Pacing: Techniques and Outcomes.

Mads Brix Kronborg1, Jens Cosedis Nielsen2.   

Abstract

Traditional right ventricular pacing prolongs the electrical and mechanical activation of the heart, which reduces the pump function, and in selected patients may lead to pacing-induced heart failure. Pacing the His bundle preserves the normal or near-normal activation pattern of the ventricles that prevents the detrimental effects of right ventricular pacing. This review discusses the techniques, feasibility, outcomes, and clinical impact of permanent His bundle pacing in patients with an indication for a cardiac implantable electronic device.

Entities:  

Keywords:  Bradycardia; Heart failure; His bundle pacing; Lead position; Resynchronization therapy

Mesh:

Year:  2016        PMID: 27315122     DOI: 10.1007/s11886-016-0748-3

Source DB:  PubMed          Journal:  Curr Cardiol Rep        ISSN: 1523-3782            Impact factor:   2.931


  41 in total

1.  Effect of cardiac resynchronization therapy on myocardial gene expression in patients with nonischemic dilated cardiomyopathy.

Authors:  Srinivas Iyengar; Garrie Haas; Sumant Lamba; David A Orsinelli; Gopal J Babu; Amy K Ferketich; Laura Yamokoski; Muthu Periasamy; William T Abraham
Journal:  J Card Fail       Date:  2007-05       Impact factor: 5.712

2.  Electrical resynchronization induced by direct His-bundle pacing.

Authors:  Daniel L Lustgarten; Susan Calame; Eric M Crespo; James Calame; Robert Lobel; Peter S Spector
Journal:  Heart Rhythm       Date:  2009-10-06       Impact factor: 6.343

3.  Speckle-tracking radial strain reveals left ventricular dyssynchrony in patients with permanent right ventricular pacing.

Authors:  Laurens F Tops; Matthew S Suffoletto; Gabe B Bleeker; Eric Boersma; Ernst E van der Wall; John Gorcsan; Martin J Schalij; Jeroen J Bax
Journal:  J Am Coll Cardiol       Date:  2007-09-04       Impact factor: 24.094

4.  Heart failure in patients with sick sinus syndrome treated with single lead atrial or dual-chamber pacing: no association with pacing mode or right ventricular pacing site.

Authors:  Sam Riahi; Jens Cosedis Nielsen; Søren Hjortshøj; Poul Erik B Thomsen; Søren Højberg; Mogens Møller; Dorthe Dalsgaard; Tonny Nielsen; Mogens Asklund; Elsebeth V Friis; Per D Christensen; Erik H Simonsen; Ulrik H Eriksen; Gunnar V H Jensen; Jesper H Svendsen; William D Toff; Jeffrey S Healey; Henning R Andersen
Journal:  Europace       Date:  2012-03-23       Impact factor: 5.214

5.  Hisian area and right ventricular apical pacing differently affect left atrial function: an intra-patients evaluation.

Authors:  Gianni Pastore; Silvio Aggio; Enrico Baracca; Chiara Fraccaro; Claudio Picariello; Loris Roncon; Giorgio Corbucci; Franco Noventa; Francesco Zanon
Journal:  Europace       Date:  2014-01-27       Impact factor: 5.214

6.  Ventricular resynchronization therapy by direct His-bundle pacing using an internal cardioverter defibrillator.

Authors:  Rafael Barba-Pichardo; Ana Manovel Sánchez; Juan M Fernández-Gómez; Pablo Moriña-Vázquez; José Venegas-Gamero; Manuel Herrera-Carranza
Journal:  Europace       Date:  2012-08-29       Impact factor: 5.214

7.  Permanent His-bundle pacing maintains long-term ventricular synchrony and left ventricular performance, unlike conventional right ventricular apical pacing.

Authors:  Domenico Catanzariti; Massimiliano Maines; Anna Manica; Carlo Angheben; Annamaria Varbaro; Giuseppe Vergara
Journal:  Europace       Date:  2012-09-20       Impact factor: 5.214

8.  His and para-His pacing in AV block: feasibility and electrocardiographic findings.

Authors:  Mads Brix Kronborg; Peter Thomas Mortensen; Jens Christian Gerdes; Henrik Kjaerulf Jensen; Jens Cosedis Nielsen
Journal:  J Interv Card Electrophysiol       Date:  2011-04-05       Impact factor: 1.900

9.  Direct His-bundle pacing: present and future.

Authors:  Pramod M Deshmukh; Mary Romanyshyn
Journal:  Pacing Clin Electrophysiol       Date:  2004-06       Impact factor: 1.976

10.  Complications after cardiac implantable electronic device implantations: an analysis of a complete, nationwide cohort in Denmark.

Authors:  Rikke Esberg Kirkfeldt; Jens Brock Johansen; Ellen Aagaard Nohr; Ole Dan Jørgensen; Jens Cosedis Nielsen
Journal:  Eur Heart J       Date:  2013-12-17       Impact factor: 29.983

View more
  3 in total

1.  In Vitro/Ex Vivo Investigation of Modified Utah Electrode Array to Selectively Sense and Pace the Sub-Surface Cardiac His Bundle.

Authors:  Ankur R Shah; Muhammad S Khan; Annie M Hirahara; Matthias Lange; Ravi Ranjan; Derek J Dosdall
Journal:  ACS Biomater Sci Eng       Date:  2020-05-07

2.  A real-time system for selectively sensing and pacing the His-bundle during sinus rhythm and ventricular fibrillation.

Authors:  Ankur R Shah; Muhammad S Khan; Annie M Hirahara; Matthias Lange; Ravi Ranjan; Derek J Dosdall
Journal:  Biomed Eng Online       Date:  2020-04-10       Impact factor: 2.819

3.  Ventricular Synchrony in Para-Hisian Cardiac Pacing as an Alternative for Physiological Cardiac Activation (Indirect Recruitment of the His Bundle?).

Authors:  Andres Di Leoni Ferrari; Guilherme Ferreira Gazzoni; Luis Manuel Ley Domingues; Jessica Caroline Feltrin Willes; Gustavo Chiari Cabral; Flavio Vinicius Costa Ferreira; Laura Orlandini Lodi; Gustavo Reis
Journal:  Arq Bras Cardiol       Date:  2022-02       Impact factor: 2.000

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.