Literature DB >> 27273115

Biomechanical deformable image registration of longitudinal lung CT images using vessel information.

Guillaume Cazoulat1, Dawn Owen, Martha M Matuszak, James M Balter, Kristy K Brock.   

Abstract

Spatial correlation of lung tissue across longitudinal images, as the patient responds to treatment, is a critical step in adaptive radiotherapy. The goal of this work is to expand a biomechanical model-based deformable registration algorithm (Morfeus) to achieve accurate registration in the presence of significant anatomical changes. Six lung cancer patients previously treated with conventionally fractionated radiotherapy were retrospectively evaluated. Exhale CT scans were obtained at treatment planning and following three weeks of treatment. For each patient, the planning CT was registered to the follow-up CT using Morfeus, a biomechanical model-based deformable registration algorithm. To model the complex response of the lung, an extension to Morfeus has been developed: an initial deformation was estimated with Morfeus consisting of boundary conditions on the chest wall and incorporating a sliding interface with the lungs. It was hypothesized that the addition of boundary conditions based on vessel tree matching would provide a robust reduction of the residual registration error. To achieve this, the vessel trees were segmented on the two images by thresholding a vesselness image based on the Hessian matrix's eigenvalues. For each point on the reference vessel tree centerline, the displacement vector was estimated by applying a variant of the Demons registration algorithm between the planning CT and the deformed follow-up CT. An expert independently identified corresponding landmarks well distributed in the lung to compute target registration errors (TRE). The TRE was: [Formula: see text], [Formula: see text] and [Formula: see text] mm after rigid registration, Morfeus and Morfeus with boundary conditions on the vessel tree, respectively. In conclusion, the addition of boundary conditions on the vessels significantly improved the accuracy in modeling the response of the lung and tumor over the course of radiotherapy. Minimizing and modeling these geometrical uncertainties will enable future plan adaptation strategies.

Entities:  

Mesh:

Year:  2016        PMID: 27273115      PMCID: PMC4975156          DOI: 10.1088/0031-9155/61/13/4826

Source DB:  PubMed          Journal:  Phys Med Biol        ISSN: 0031-9155            Impact factor:   3.609


  32 in total

1.  Respiratory lung motion analysis using a nonlinear motion correction technique for respiratory-gated lung perfusion SPECT images.

Authors:  Hidenori Ue; Hideaki Haneishi; Hideyuki Iwanaga; Kazuyoshi Suga
Journal:  Ann Nucl Med       Date:  2007-06       Impact factor: 2.668

2.  Estimation of slipping organ motion by registration with direction-dependent regularization.

Authors:  Alexander Schmidt-Richberg; René Werner; Heinz Handels; Jan Ehrhardt
Journal:  Med Image Anal       Date:  2011-06-26       Impact factor: 8.545

3.  Piecewise-diffeomorphic image registration: application to the motion estimation between 3D CT lung images with sliding conditions.

Authors:  Laurent Risser; François-Xavier Vialard; Habib Y Baluwala; Julia A Schnabel
Journal:  Med Image Anal       Date:  2012-11-02       Impact factor: 8.545

4.  Adaptive radiotherapy in lung cancer: dosimetric benefits and clinical outcome.

Authors:  T Kataria; D Gupta; S S Bisht; N Karthikeyan; S Goyal; L Pushpan; A Abhishek; H B Govardhan; V Kumar; K Sharma; S Jain; T Basu; A Srivastava
Journal:  Br J Radiol       Date:  2014-03-17       Impact factor: 3.039

Review 5.  Adaptive radiotherapy for lung cancer.

Authors:  Jan-Jakob Sonke; José Belderbos
Journal:  Semin Radiat Oncol       Date:  2010-04       Impact factor: 5.934

6.  Validation of an accelerated 'demons' algorithm for deformable image registration in radiation therapy.

Authors:  He Wang; Lei Dong; Jennifer O'Daniel; Radhe Mohan; Adam S Garden; K Kian Ang; Deborah A Kuban; Mark Bonnen; Joe Y Chang; Rex Cheung
Journal:  Phys Med Biol       Date:  2005-06-01       Impact factor: 3.609

7.  Potential of adaptive radiotherapy to escalate the radiation dose in combined radiochemotherapy for locally advanced non-small cell lung cancer.

Authors:  Matthias Guckenberger; Juergen Wilbert; Anne Richter; Kurt Baier; Michael Flentje
Journal:  Int J Radiat Oncol Biol Phys       Date:  2010-08-12       Impact factor: 7.038

8.  Evaluation of 4-dimensional computed tomography to 4-dimensional cone-beam computed tomography deformable image registration for lung cancer adaptive radiation therapy.

Authors:  Salim Balik; Elisabeth Weiss; Nuzhat Jan; Nicholas Roman; William C Sleeman; Mirek Fatyga; Gary E Christensen; Cheng Zhang; Martin J Murphy; Jun Lu; Paul Keall; Jeffrey F Williamson; Geoffrey D Hugo
Journal:  Int J Radiat Oncol Biol Phys       Date:  2013-02-22       Impact factor: 7.038

9.  Patient-specific finite element modeling of respiratory lung motion using 4D CT image data.

Authors:  René Werner; Jan Ehrhardt; Rainer Schmidt; Heinz Handels
Journal:  Med Phys       Date:  2009-05       Impact factor: 4.071

10.  Improving Intensity-Based Lung CT Registration Accuracy Utilizing Vascular Information.

Authors:  Kunlin Cao; Kai Ding; Joseph M Reinhardt; Gary E Christensen
Journal:  Int J Biomed Imaging       Date:  2012-11-28
View more
  13 in total

1.  The VAMPIRE challenge: A multi-institutional validation study of CT ventilation imaging.

Authors:  John Kipritidis; Bilal A Tahir; Guillaume Cazoulat; Michael S Hofman; Shankar Siva; Jason Callahan; Nicholas Hardcastle; Tokihiro Yamamoto; Gary E Christensen; Joseph M Reinhardt; Noriyuki Kadoya; Taylor J Patton; Sarah E Gerard; Isabella Duarte; Ben Archibald-Heeren; Mikel Byrne; Rick Sims; Scott Ramsay; Jeremy T Booth; Enid Eslick; Fiona Hegi-Johnson; Henry C Woodruff; Rob H Ireland; Jim M Wild; Jing Cai; John E Bayouth; Kristy Brock; Paul J Keall
Journal:  Med Phys       Date:  2019-02-01       Impact factor: 4.071

2.  Automatic large quantity landmark pairs detection in 4DCT lung images.

Authors:  Yabo Fu; Xue Wu; Allan M Thomas; Harold H Li; Deshan Yang
Journal:  Med Phys       Date:  2019-08-07       Impact factor: 4.071

3.  Detection of vessel bifurcations in CT scans for automatic objective assessment of deformable image registration accuracy.

Authors:  Guillaume Cazoulat; Brian M Anderson; Molly M McCulloch; Bastien Rigaud; Eugene J Koay; Kristy K Brock
Journal:  Med Phys       Date:  2021-08-25       Impact factor: 4.506

4.  Implementing Radiation Dose-Volume Liver Response in Biomechanical Deformable Image Registration.

Authors:  Daniel F Polan; Mary Feng; Theodore S Lawrence; Randall K Ten Haken; Kristy K Brock
Journal:  Int J Radiat Oncol Biol Phys       Date:  2017-06-27       Impact factor: 7.038

5.  CALIPER: A deformable image registration algorithm for large geometric changes during radiotherapy for locally advanced non-small cell lung cancer.

Authors:  Christopher L Guy; Elisabeth Weiss; Gary E Christensen; Nuzhat Jan; Geoffrey D Hugo
Journal:  Med Phys       Date:  2018-04-16       Impact factor: 4.071

6.  A hybrid, image-based and biomechanics-based registration approach to markerless intraoperative nodule localization during video-assisted thoracoscopic surgery.

Authors:  Pablo Alvarez; Simon Rouzé; Michael I Miga; Yohan Payan; Jean-Louis Dillenseger; Matthieu Chabanas
Journal:  Med Image Anal       Date:  2021-01-30       Impact factor: 13.828

7.  The evaluation of a hybrid biomechanical deformable registration method on a multistage physical phantom with reproducible deformation.

Authors:  An Qin; Dan Ionascu; Jian Liang; Xiao Han; Nicolette O'Connell; Di Yan
Journal:  Radiat Oncol       Date:  2018-12-04       Impact factor: 3.481

8.  Line-Enhanced Deformable Registration of Pulmonary Computed Tomography Images Before and After Radiation Therapy With Radiation-Induced Fibrosis.

Authors:  Martin King; William F Sensakovic; Peter Maxim; Maximilian Diehn; Billy W Loo; Lei Xing
Journal:  Technol Cancer Res Treat       Date:  2018-01-01

9.  Validation of a CT-based motion model with in-situ fluoroscopy for lung surface deformation estimation.

Authors:  M Ranjbar; P Sabouri; S Mossahebi; A Sawant; P Mohindra; G Lasio; L D Timmie Topoleski
Journal:  Phys Med Biol       Date:  2021-02-16       Impact factor: 3.609

10.  Vasculature-Driven Biomechanical Deformable Image Registration of Longitudinal Liver Cholangiocarcinoma Computed Tomographic Scans.

Authors:  Guillaume Cazoulat; Dalia Elganainy; Brian M Anderson; Mohamed Zaid; Peter C Park; Eugene J Koay; Kristy K Brock
Journal:  Adv Radiat Oncol       Date:  2019-10-17
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.