Literature DB >> 19544766

Patient-specific finite element modeling of respiratory lung motion using 4D CT image data.

René Werner1, Jan Ehrhardt, Rainer Schmidt, Heinz Handels.   

Abstract

Development and optimization of methods for adequately accounting for respiratory motion in radiation therapy of thoracic tumors require detailed knowledge of respiratory dynamics and its impact on corresponding dose distributions. Thus, computer aided modeling and simulation of respiratory motion have become increasingly important. In this article a biophysical approach for modeling respiratory lung motion is described: Major aspects of the process of lung ventilation are formulated as a contact problem of elasticity theory which is solved by finite element methods; lung tissue is assumed to be isotropic, homogeneous, and linearly elastic. A main focus of the article is to assess the impact of biomechanical parameters (values of elastic constants) on the modeling process and to evaluate modeling accuracy. Patient-specific models are generated based on 4D CT data of 12 lung tumor patients. Simulated motion patterns of inner lung landmarks are compared with corresponding motion patterns observed in the 4D CT data. Mean absolute differences between model-based predicted landmark motion and corresponding breathing-induced landmark displacements as observed in the CT data sets are in the order of 3 mm (end expiration to end inspiration) and 2 mm (end expiration to midrespiration). Modeling accuracy decreases with increasing tumor size both locally (landmarks close to tumor) and globally (landmarks in other parts of the lung). The impact of the values of the elastic constants appears to be small. Outcomes show that the modeling approach is an adequate strategy in predicting lung dynamics due to lung ventilation. Nevertheless, the decreased prediction quality in cases of large tumors demands further study of the influence of lung tumors on global and local lung elasticity properties.

Entities:  

Mesh:

Year:  2009        PMID: 19544766     DOI: 10.1118/1.3101820

Source DB:  PubMed          Journal:  Med Phys        ISSN: 0094-2405            Impact factor:   4.071


  41 in total

1.  Analysis of deformable image registration accuracy using computational modeling.

Authors:  Hualiang Zhong; Jinkoo Kim; Indrin J Chetty
Journal:  Med Phys       Date:  2010-03       Impact factor: 4.071

2.  A hybrid biomechanical intensity based deformable image registration of lung 4DCT.

Authors:  Navid Samavati; Michael Velec; Kristy Brock
Journal:  Phys Med Biol       Date:  2015-04-01       Impact factor: 3.609

3.  Predictive modeling of lung motion over the entire respiratory cycle using measured pressure-volume data, 4DCT images, and finite-element analysis.

Authors:  Jaesung Eom; Xie George Xu; Suvranu De; Chengyu Shi
Journal:  Med Phys       Date:  2010-08       Impact factor: 4.071

4.  Quadratic penalty method for intensity-based deformable image registration and 4DCT lung motion recovery.

Authors:  Edward Castillo
Journal:  Med Phys       Date:  2019-03-14       Impact factor: 4.071

Review 5.  What can imaging tell us about physiology? Lung growth and regional mechanical strain.

Authors:  Connie C W Hsia; Merryn H Tawhai
Journal:  J Appl Physiol (1985)       Date:  2012-05-10

6.  Use of MRI to assess the prediction of heart motion with gross body motion in myocardial perfusion imaging by stereotracking of markers on the body surface.

Authors:  Michael A King; Joyoni Dey; Karen Johnson; Paul Dasari; Joyeeta M Mukherjee; Joseph E McNamara; Arda Konik; Cliff Lindsay; Shaokuan Zheng; Dennis Coughlin
Journal:  Med Phys       Date:  2013-11       Impact factor: 4.071

Review 7.  Deformable medical image registration: a survey.

Authors:  Aristeidis Sotiras; Christos Davatzikos; Nikos Paragios
Journal:  IEEE Trans Med Imaging       Date:  2013-05-31       Impact factor: 10.048

8.  Mapping cyclic stretch in the postpneumonectomy murine lung.

Authors:  Nenad Filipovic; Barry C Gibney; Milos Kojic; Dalibor Nikolic; Velibor Isailovic; Alexandra Ysasi; Moritz A Konerding; Steven J Mentzer; Akira Tsuda
Journal:  J Appl Physiol (1985)       Date:  2013-08-29

9.  Automated identification and reduction of artifacts in cine four-dimensional computed tomography (4DCT) images using respiratory motion model.

Authors:  Min Li; Sarah Joy Castillo; Richard Castillo; Edward Castillo; Thomas Guerrero; Liang Xiao; Xiaolin Zheng
Journal:  Int J Comput Assist Radiol Surg       Date:  2017-02-14       Impact factor: 2.924

10.  Vascular smooth muscle cell functional contractility depends on extracellular mechanical properties.

Authors:  Kerianne E Steucke; Paige V Tracy; Eric S Hald; Jennifer L Hall; Patrick W Alford
Journal:  J Biomech       Date:  2015-08-07       Impact factor: 2.712

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.