Literature DB >> 15930609

Validation of an accelerated 'demons' algorithm for deformable image registration in radiation therapy.

He Wang1, Lei Dong, Jennifer O'Daniel, Radhe Mohan, Adam S Garden, K Kian Ang, Deborah A Kuban, Mark Bonnen, Joe Y Chang, Rex Cheung.   

Abstract

A greyscale-based fully automatic deformable image registration algorithm, originally known as the 'demons' algorithm, was implemented for CT image-guided radiotherapy. We accelerated the algorithm by introducing an 'active force' along with an adaptive force strength adjustment during the iterative process. These improvements led to a 40% speed improvement over the original algorithm and a high tolerance of large organ deformations. We used three methods to evaluate the accuracy of the algorithm. First, we created a set of mathematical transformations for a series of patient's CT images. This provides a 'ground truth' solution for quantitatively validating the deformable image registration algorithm. Second, we used a physically deformable pelvic phantom, which can measure deformed objects under different conditions. The results of these two tests allowed us to quantify the accuracy of the deformable registration. Validation results showed that more than 96% of the voxels were within 2 mm of their intended shifts for a prostate and a head-and-neck patient case. The mean errors and standard deviations were 0.5 mm+/-1.5 mm and 0.2 mm+/-0.6 mm, respectively. Using the deformable pelvis phantom, the result showed a tracking accuracy of better than 1.5 mm for 23 seeds implanted in a phantom prostate that was deformed by inflation of a rectal balloon. Third, physician-drawn contours outlining the tumour volumes and certain anatomical structures in the original CT images were deformed along with the CT images acquired during subsequent treatments or during a different respiratory phase for a lung cancer case. Visual inspection of the positions and shapes of these deformed contours agreed well with human judgment. Together, these results suggest that the accelerated demons algorithm has significant potential for delineating and tracking doses in targets and critical structures during CT-guided radiotherapy.

Entities:  

Mesh:

Year:  2005        PMID: 15930609     DOI: 10.1088/0031-9155/50/12/011

Source DB:  PubMed          Journal:  Phys Med Biol        ISSN: 0031-9155            Impact factor:   3.609


  167 in total

1.  Evaluation of multiple-atlas-based strategies for segmentation of the thyroid gland in head and neck CT images for IMRT.

Authors:  A Chen; K J Niermann; M A Deeley; B M Dawant
Journal:  Phys Med Biol       Date:  2011-11-29       Impact factor: 3.609

2.  A stochastic approach to estimate the uncertainty of dose mapping caused by uncertainties in b-spline registration.

Authors:  Martina Hub; Christian Thieke; Marc L Kessler; Christian P Karger
Journal:  Med Phys       Date:  2012-04       Impact factor: 4.071

Review 3.  Current progress in adaptive radiation therapy for head and neck cancer.

Authors:  David L Schwartz
Journal:  Curr Oncol Rep       Date:  2012-04       Impact factor: 5.075

4.  Extraction of tumor motion trajectories using PICCS-4DCBCT: a validation study.

Authors:  Zhihua Qi; Guang-Hong Chen
Journal:  Med Phys       Date:  2011-10       Impact factor: 4.071

5.  Analysis of deformable image registration accuracy using computational modeling.

Authors:  Hualiang Zhong; Jinkoo Kim; Indrin J Chetty
Journal:  Med Phys       Date:  2010-03       Impact factor: 4.071

6.  A pseudoinverse deformation vector field generator and its applications.

Authors:  C Yan; H Zhong; M Murphy; E Weiss; J V Siebers
Journal:  Med Phys       Date:  2010-03       Impact factor: 4.071

7.  Multi-scale regularization approaches of non-parametric deformable registrations.

Authors:  Hsiang-Chi Kuo; Keh-Shih Chuang; Dennis Mah; Andrew Wu; Linda Hong; Ravindra Yaparpalvi; Shalom Kalnicki
Journal:  J Digit Imaging       Date:  2011-08       Impact factor: 4.056

8.  Sequential Registration-Based Segmentation of the Prostate Gland in MR Image Volumes.

Authors:  Farzad Khalvati; Aryan Salmanpour; Shahryar Rahnamayan; Masoom A Haider; H R Tizhoosh
Journal:  J Digit Imaging       Date:  2016-04       Impact factor: 4.056

9.  Patient-specific quantification of respiratory motion-induced dose uncertainty for step-and-shoot IMRT of lung cancer.

Authors:  Heng Li; Peter Park; Wei Liu; Jason Matney; Zhongxing Liao; Peter Balter; Yupeng Li; Xiaodong Zhang; Xiaoqiang Li; X Ronald Zhu
Journal:  Med Phys       Date:  2013-12       Impact factor: 4.071

10.  CT to cone-beam CT deformable registration with simultaneous intensity correction.

Authors:  Xin Zhen; Xuejun Gu; Hao Yan; Linghong Zhou; Xun Jia; Steve B Jiang
Journal:  Phys Med Biol       Date:  2012-10-03       Impact factor: 3.609

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.