PURPOSE: The purpose of this study was to demonstrate the dosimetric and clinical feasibility of image guided radiation therapy (IGRT) combined with high-dose-rate (HDR) intracavitary brachytherapy (ICBT) to improve dose distribution in cervical cancer treatment.Entities:
Keywords: HDR brachytherapy; IGRT; cervical cancer
Year: 2016 PMID: 27257416 PMCID: PMC4873551 DOI: 10.5114/jcb.2016.59282
Source DB: PubMed Journal: J Contemp Brachytherapy ISSN: 2081-2841
Fig. 1A sample dose distribution from intracavitary brachytherapy (ICBT) (A), image guided radiation therapy (IGRT) (B), and B + I (ICBT + IGRT) (C) plan for one fraction
EQD2 dose comparison between B + I (ICBT + IGRT) and optimized ICBT (O-ICBT) for targets and OARs for 42 patients. The mean and SD values are listed for each parameter. P-value corresponds to pair-wise comparison
| B + I | O-ICBT |
| |
|---|---|---|---|
| HRCTV D100% | 71.01 Gy (1.57) | 60.49 Gy (2.19) | < 0.01 |
| HRCTV D90% | 84.97 Gy (1.65) | 84.90 Gy (0.63) | 0.82 |
| HRCTV D50% | 106.29 Gy (5.69) | 114.63 Gy (7.84) | < 0.01 |
| IRCTV D100% | 61.99 Gy (1.18) | 56.38 Gy (1.38) | < 0.01 |
| IRCTV D90% | 76.52 Gy (0.58) | 73.82 Gy (3.04) | < 0.01 |
| IRCTV D50% | 90.69 Gy (2.81) | 99.81 Gy (4.57) | < 0.01 |
| Bladder D2cc | 74.73 Gy (2.07) | 86.09 Gy (3.27) | < 0.01 |
| Rectum D2cc | 70.12 Gy (2.00) | 72.90 Gy (4.03) | < 0.01 |
| Sigmoid D2cc | 70.62 Gy (3.19) | 73.27 Gy (3.58) | < 0.01 |
| Bladder V60 Gy | 52.84 cc (8.68) | 44.19 cc (6.75) | < 0.01 |
| Rectum V60 Gy | 19.80 cc (4.76) | 18.63 cc (3.48) | 0.07 |
| Sigmoid V60 Gy | 30.74 cc (8.86) | 19.25 cc (5.39) | < 0.01 |
HRCTV – high risk clinical target volume, IRCTV – intermediate risk clinical target volume, D100%, D90%, D50% – the minimum dose received by 100, 90, and 50% of the prostate volume, D2cc – minimum dose to the most exposed 2 cm3, V60 Gy represents the volume irradiated to more than 60 Gy (EQD2) by the accumulated dose from EBRT and brachytherapy boost
Fig. 2Comparison of a typical dose volume histograms (DVHs) for B + I (ICBT + IGRT) (solid line) and optimized ICBT (O-ICBT) (dashed line) techniques