Literature DB >> 15124990

A treatment planning study comparing HDR and AGIMRT for cervical cancer.

Sasha H Wahab1, Robert S Malyapa, Sasa Mutic, Perry W Grigsby, Joseph O Deasy, Tom R Miller, Imran Zoberi, Daniel A Low.   

Abstract

The customization of brachytherapy dose distributions for gynecologic malignancies is limited by the spatial positioning of the applicators. We tested the hypothesis that applicator-guided intensity modulated radiation therapy (AGIMRT) has the potential to deliver highly conformal dose distributions to cervical tumors, representing improvement over distributions obtained with intracavitary brachytherapy. A commercial three-dimensional (3-D) treatment planning system was used to create plans for ten cervical cancer patients treated at our institution. Dose distributions of conventionally designed high dose rate (HDR) plans were compared against those of AGIMRT. Tumor delineation was based on a previously published binary threshold technique, using image intensity on positron emission tomography (PET) scans. AGIMRT treatment schedules were designed using two fraction sizes: 6.5 Gy, to directly reproduce the HDR fractionation, and 1.8 Gy, to simulate traditional external beam fractionation. The average minimum tumor dose was significantly greater for the AGIMRT dose distributions than for the HDR distributions (64.2 Gy vs 33.6 Gy; p = 0.005). The mean percent tumor volume at the prescription dose was higher for the AGIMRT plans (90.0% vs 58.2%; p = 0.005). Using AGIMRT, the mean percent volume at the tolerance limit was decreased for the bladder (6.1% vs 16.6%; p = 0.047) but increased for the rectum (4.1% vs 2.2%; p = 0.646). Our study suggests that there may be conceptual and dosimetric advantages to replacing HDR with AGIMRT for patients with large-volume cervical tumors. This investigation is being expanded using sequential PET images to model tumor regression and compare brachytherapy and AGIMRT throughout the course of therapy.

Entities:  

Mesh:

Year:  2004        PMID: 15124990     DOI: 10.1118/1.1645678

Source DB:  PubMed          Journal:  Med Phys        ISSN: 0094-2405            Impact factor:   4.071


  8 in total

1.  High dose three-dimensional conformal boost using the real-time tumor tracking radiotherapy system in cervical cancer patients unable to receive intracavitary brachytherapy.

Authors:  Hee Chul Park; Shinichi Shimizu; Akio Yonesaka; Kazuhiko Tsuchiya; Yasuhiko Ebina; Hiroshi Taguchi; Norio Katoh; Rumiko Kinoshita; Masayori Ishikawa; Noriaki Sakuragi; Hiroki Shirato
Journal:  Yonsei Med J       Date:  2009-12-29       Impact factor: 2.759

2.  Dosimetric comparison of high dose rate brachytherapy and intensity-modulated radiation therapy for cervical carcinoma.

Authors:  B Shwetha; M Ravikumar; Siddanna R Palled; Sanjay S Supe; S Sathiyan
Journal:  J Med Phys       Date:  2011-04

3.  Interstitial brachytherapy guided intensity modulated radiation therapy (IBGIMRT) in cervical cancer: a dosimetric study.

Authors:  Daya Nand Sharma; V Subramani; Goura Kisor Rath; K S Jothybasu; Amit Bahl; Parmod Kumar Julka; N Gopishankar
Journal:  J Contemp Brachytherapy       Date:  2009-07-17

4.  Retrospective feasibility study of simultaneous integrated boost in cervical cancer using Tomotherapy: the impact of organ motion and tumor regression.

Authors:  Fernanda G Herrera; Sharon Callaway; Ela Delikgoz-Soykut; Mehtap Coskun; Laetitia Porta; Jean-Yves Meuwly; Joao Soares-Rodrigues; Leonie Heym; Raphael Moeckli; Mahmut Ozsahin
Journal:  Radiat Oncol       Date:  2013-01-03       Impact factor: 3.481

5.  Is there a role for an external beam boost in cervical cancer radiotherapy?

Authors:  Rajni A Sethi; Gabor Jozsef; David Grew; Ariel Marciscano; Ryan Pennell; Melissa Babcock; Allison McCarthy; John Curtin; Peter B Schiff
Journal:  Front Oncol       Date:  2013-01-30       Impact factor: 6.244

6.  Image guided radiation therapy boost in combination with high-dose-rate intracavitary brachytherapy for the treatment of cervical cancer.

Authors:  Xianliang Wang; Jie Li; Pei Wang; Ke Yuan; Gang Yin; Bin Wan
Journal:  J Contemp Brachytherapy       Date:  2016-04-14

7.  Dosimetric study for cervix carcinoma treatment using intensity modulated radiation therapy (IMRT) compensation based on 3D intracavitary brachytherapy technique.

Authors:  Gang Yin; Pei Wang; Jinyi Lang; Yin Tian; Yangkun Luo; Zixuan Fan; Kin Yip Tam
Journal:  J Contemp Brachytherapy       Date:  2016-06-14

8.  Local tumor control probability to evaluate an applicator-guided volumetric-modulated arc therapy solution as alternative of 3D brachytherapy for the treatment of the vaginal vault in patients affected by gynecological cancer.

Authors:  Piernicola Pedicini; Lidia Strigari; Rocchina Caivano; Alba Fiorentino; Giorgia Califano; Antonio Nappi; Giuseppina Improta; Giovanni Storto; Mariella Cozzolino; Costanza Chiumento; Vincenzo Fusco; Andrea Vavassori; Marcello Benassi; Roberto Orecchia; Marco Salvatore
Journal:  J Appl Clin Med Phys       Date:  2013-03-04       Impact factor: 2.102

  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.