Literature DB >> 27206280

Ion mobility spectrometry nuisance alarm threshold analysis for illicit narcotics based on environmental background and a ROC-curve approach.

Thomas P Forbes1, Marcela Najarro.   

Abstract

The discriminative potential of an ion mobility spectrometer (IMS) for trace detection of illicit narcotics relative to environmental background was investigated with a receiver operating characteristic (ROC) curve framework. The IMS response of cocaine, heroin, methamphetamine, 3,4-methylenedioxymethamphetamine (MDMA), and Δ(9)-tetrahydro-cannabinol (THC) was evaluated against environmental background levels derived from the screening of incoming delivery vehicles at a federal facility. Over 20 000 samples were collected over a multiyear period under two distinct sets of instrument operating conditions, a baseline mode and an increased desorption/drift tube temperature and sampling time mode. ROC curves provided a quantifiable representation of the interplay between sensitivity (true positive rate, TPR) and specificity (1 - false positive rate, FPR). A TPR of 90% and minimized FPR were targeted as the detection limits of IMS for the selected narcotics. MDMA, THC, and cocaine demonstrated single nanogram sensitivity at 90% TPR and <10% FPR, with improvements to both MDMA and cocaine in the elevated temperature/increased sampling mode. Detection limits in the tens of nanograms with poor specificity (FPR ≈ 20%) were observed for methamphetamine and heroin under baseline conditions. However, elevating the temperature reduced the background in the methamphetamine window, drastically improving its response (90% TPR and 3.8% FPR at 1 ng). On the contrary, the altered mode conditions increased the level of background for THC and heroin, partially offsetting observed enhancements to desorption. The presented framework demonstrated the significant effect environmental background distributions have on sensitivity and specificity.

Entities:  

Mesh:

Substances:

Year:  2016        PMID: 27206280      PMCID: PMC5054301          DOI: 10.1039/c6an00844e

Source DB:  PubMed          Journal:  Analyst        ISSN: 0003-2654            Impact factor:   4.616


  36 in total

1.  Evaluation of a rapid whole blood ELISA for quantification of troponin I in patients with acute chest pain.

Authors:  C Heeschen; B U Goldmann; L Langenbrink; G Matschuck; C W Hamm
Journal:  Clin Chem       Date:  1999-10       Impact factor: 8.327

2.  Drugs of abuse in airborne particulates in urban environments.

Authors:  M Viana; X Querol; A Alastuey; C Postigo; M J López de Alda; D Barceló; B Artíñano
Journal:  Environ Int       Date:  2010-05-05       Impact factor: 9.621

3.  Miniaturized low-cost ion mobility spectrometer for fast detection of chemical warfare agents.

Authors:  Stefan Zimmermann; Sebastian Barth; Wolfgang K M Baether; Joachim Ringer
Journal:  Anal Chem       Date:  2008-07-30       Impact factor: 6.986

4.  Thermal desorption counter-flow introduction atmospheric pressure chemical ionization for direct mass spectrometry of ecstasy tablets.

Authors:  Hiroyuki Inoue; Hiroaki Hashimoto; Susumu Watanabe; Yuko T Iwata; Tatsuyuki Kanamori; Hajime Miyaguchi; Kenji Tsujikawa; Kenji Kuwayama; Noriyuki Tachi; Naohito Uetake
Journal:  J Mass Spectrom       Date:  2009-09       Impact factor: 1.982

5.  Forensic application of chiral separation of amphetamine-type stimulants to impurity analysis of seized methamphetamine by capillary electrophoresis.

Authors:  Yuko T Iwata; Hiroyuki Inoue; Kenji Kuwayama; Tatsuyuki Kanamori; Kenji Tsujikawa; Hajime Miyaguchi; Tohru Kishi
Journal:  Forensic Sci Int       Date:  2006-07-25       Impact factor: 2.395

6.  Smooth non-parametric receiver operating characteristic (ROC) curves for continuous diagnostic tests.

Authors:  K H Zou; W J Hall; D E Shapiro
Journal:  Stat Med       Date:  1997-10-15       Impact factor: 2.373

7.  Assay of major and minor constituents of opium samples and studies of their origin.

Authors:  K Narayanaswami; H C Golani; R D Dua
Journal:  Forensic Sci Int       Date:  1979-11       Impact factor: 2.395

8.  Detection of drug residues on the hands of subjects by surface sampling and ion mobility spectrometry.

Authors:  A H Lawrence
Journal:  Forensic Sci Int       Date:  1987 May-Jun       Impact factor: 2.395

9.  Hepascore: an accurate validated predictor of liver fibrosis in chronic hepatitis C infection.

Authors:  Leon A Adams; Max Bulsara; Enrico Rossi; Bastiaan DeBoer; David Speers; Jacob George; James Kench; Geoffrey Farrell; Geoffrey W McCaughan; Gary P Jeffrey
Journal:  Clin Chem       Date:  2005-07-28       Impact factor: 8.327

10.  Desorption electro-flow focusing ionization of explosives and narcotics for ambient pressure mass spectrometry.

Authors:  Thomas P Forbes; Tim M Brewer; Greg Gillen
Journal:  Analyst       Date:  2013-10-07       Impact factor: 4.616

View more
  6 in total

1.  Detection of Nonvolatile Inorganic Oxidizer-Based Explosives from Wipe Collections by Infrared Thermal Desorption-Direct Analysis in Real Time Mass Spectrometry.

Authors:  Thomas P Forbes; Edward Sisco; Matthew Staymates
Journal:  Anal Chem       Date:  2018-05-07       Impact factor: 6.986

2.  Discriminative potential of ion mobility spectrometry for the detection of fentanyl and fentanyl analogues relative to confounding environmental interferents.

Authors:  Thomas P Forbes; Jeffrey Lawrence; Jennifer R Verkouteren; R Michael Verkouteren
Journal:  Analyst       Date:  2019-10-03       Impact factor: 4.616

Review 3.  Interpol review of controlled substances 2016-2019.

Authors:  Nicole S Jones; Jeffrey H Comparin
Journal:  Forensic Sci Int Synerg       Date:  2020-05-24

4.  Broad spectrum infrared thermal desorption of wipe-based explosive and narcotic samples for trace mass spectrometric detection.

Authors:  Thomas P Forbes; Matthew Staymates; Edward Sisco
Journal:  Analyst       Date:  2017-08-07       Impact factor: 4.616

5.  Rapid Discrimination of Citrus reticulata 'Chachi' by Electrospray Ionization-Ion Mobility-High-Resolution Mass Spectrometry.

Authors:  Juan Liu; Keke Wang; Yuling Li; Bowen Zhou; Kuofeng Tseng; Xiaoqiang Zhang; Yue Su; Wenjian Sun; Yinlong Guo
Journal:  Molecules       Date:  2021-11-20       Impact factor: 4.411

6.  Statistical analysis for explosives detection system test and evaluation.

Authors:  Stefan Lukow; James C Weatherall
Journal:  Sci Rep       Date:  2022-01-07       Impact factor: 4.996