Literature DB >> 31579898

Discriminative potential of ion mobility spectrometry for the detection of fentanyl and fentanyl analogues relative to confounding environmental interferents.

Thomas P Forbes1, Jeffrey Lawrence, Jennifer R Verkouteren, R Michael Verkouteren.   

Abstract

The opioid crisis and emergence of fentanyl, fentanyl analogues, and other synthetic opioids has highlighted the need for sensitive and robust detection for interdiction at screening points, notably vehicles at border crossings and packages at postal facilities. This work investigates the discriminative potential, sensitivity and specificity, of ion mobility spectrometry (IMS) for the detection of fentanyl and fifteen (15) fentanyl-related compounds (analogues, other opioids, and metabolites) relative to confounding environmental interferents. The environmental background interferent levels, frequency and intensity, were derived from over 10 000 screening samples collected from delivery vehicles entering a federal site. A receiver operating characteristic (ROC) curve methodology was employed to quantify the relationship between sensitivity and specificity for these target compounds on two instruments/configurations. These instrument configurations differed in desorption and drift tube temperatures, reactant ion dopant chemistry, and analysis time. This work identified reduced mobility areas of high interference that resulted in increased false positive rates (FPR), effectively reducing sensitivity (true positive rate: TPR) in those regions. Except for a few target compounds on either of the instruments that exhibited elevated FPRs, detection of fentanyl and fentanyl-related species was achieved at single to tens of nanograms with ≥90% TPR and ≤2% FPR. This work established the importance of systematic environmental background characterization at each specific screening setting in evaluating a platform's true performance.

Entities:  

Mesh:

Substances:

Year:  2019        PMID: 31579898      PMCID: PMC7008973          DOI: 10.1039/c9an01771b

Source DB:  PubMed          Journal:  Analyst        ISSN: 0003-2654            Impact factor:   4.616


  29 in total

1.  Evaluation of a rapid whole blood ELISA for quantification of troponin I in patients with acute chest pain.

Authors:  C Heeschen; B U Goldmann; L Langenbrink; G Matschuck; C W Hamm
Journal:  Clin Chem       Date:  1999-10       Impact factor: 8.327

2.  Drugs of abuse in airborne particulates in urban environments.

Authors:  M Viana; X Querol; A Alastuey; C Postigo; M J López de Alda; D Barceló; B Artíñano
Journal:  Environ Int       Date:  2010-05-05       Impact factor: 9.621

3.  ROC-curve approach for determining the detection limit of a field chemical sensor.

Authors:  Carlos G Fraga; Angela M Melville; Bob W Wright
Journal:  Analyst       Date:  2006-12-22       Impact factor: 4.616

Review 4.  Adulterants in illicit drugs: a review of empirical evidence.

Authors:  Claire Cole; Lisa Jones; Jim McVeigh; Andrew Kicman; Qutub Syed; Mark Bellis
Journal:  Drug Test Anal       Date:  2010-12-29       Impact factor: 3.345

5.  Analysis of gaseous toxic industrial compounds and chemical warfare agent simulants by atmospheric pressure ionization mass spectrometry.

Authors:  Ismael Cotte-Rodríguez; Dina R Justes; Sergio C Nanita; Robert J Noll; Christopher C Mulligan; Nathaniel L Sanders; R Graham Cooks
Journal:  Analyst       Date:  2006-01-18       Impact factor: 4.616

6.  Performance metrics based on signal intensity for ion mobility spectrometry--based explosive trace detectors using inkjet printed materials.

Authors:  J R Verkouteren; J Lawrence; G A Klouda; M Najarro; J Grandner; R M Verkouteren; S J York
Journal:  Analyst       Date:  2014-11-07       Impact factor: 4.616

7.  Determination of drugs of abuse in airborne particles by pressurized liquid extraction and liquid chromatography-electrospray-tandem mass spectrometry.

Authors:  Cristina Postigo; Maria J Lopez de Alda; Mar Viana; Xavier Querol; Andrés Alastuey; Begoña Artiñano; Damià Barceló
Journal:  Anal Chem       Date:  2009-06-01       Impact factor: 6.986

8.  Quantitative analysis of morphine and noscapine using corona discharge ion mobility spectrometry with ammonia reagent gas.

Authors:  T Khayamian; M Tabrizchi; M T Jafari
Journal:  Talanta       Date:  2005-12-15       Impact factor: 6.057

9.  Evaluation of suspected interferents for TNT detection by ion mobility spectrometry.

Authors:  L M Matz; P S Tornatore; H H Hill
Journal:  Talanta       Date:  2001-03-30       Impact factor: 6.057

10.  Detection of cocaine in the airborne particles of the Italian cities Rome and Taranto.

Authors:  Angelo Cecinato; Catia Balducci
Journal:  J Sep Sci       Date:  2007-08       Impact factor: 3.645

View more
  1 in total

1.  Accurate prediction of terahertz spectra of molecular crystals of fentanyl and its analogs.

Authors:  Chun-Hung Wang; Anthony C Terracciano; Artёm E Masunov; Mengyu Xu; Subith S Vasu
Journal:  Sci Rep       Date:  2021-02-18       Impact factor: 4.379