Literature DB >> 27198891

Clinical, angiographic and procedural characteristics of longitudinal stent deformation.

A Guler1, Y Guler2, E Acar2, S M Aung2, S C Efe2, A Kilicgedik2, C Y Karabay2, S Barutcu2, M K Tigen3, S Pala2, A İzgi2, A M Esen2, C Kirma2.   

Abstract

Recently, longitudinal stent deformation (LSD) has been reported increasingly. Even though the reported cases included almost all stent designs, most cases were seen in the Element™ stent design (Boston Scientific, Natick, MA, USA). It is considered that stent design, lesion and procedural characteristics play a role in the etiology of LSD. Yet, the effect of LSD on long-term clinical outcomes has not been studied well. Element stents implanted between January 2013 and April 2015 in our hospital were examined retrospectively. Patients were grouped into two according to the presence of LSD, and their clinical, lesion and procedural characteristics were studied. Twenty-four LSD's were detected in 1812 Element stents deployed in 1314 patients (1.83 % of PCI cases and 1.32 % of all Element stents). LMCA lesions (16.7 % vs 1.6 %, p < 0.001), complex lesions (75 % vs 35.1 %, p < 0.001), bifurcation lesions (37.5 % vs 18.3 %, p = 0.017), ostial lesions (33.3 % vs 12.8 %, p = 0.003), using of extra-support guiding catheter (54.2 % vs 22.3 %, p < 0.001) and extra-support guidewire (37.5 % vs 16.2 %, p = 0.005) were found to be more frequent in cases with LSD than in cases without it. In addition, the number of stents, stent inflation pressure and the use of post-dilatation were significantly different between the two groups. Two patients had an adverse event during the follow-up period. LSD is a rarely encountered complication, and is more common in complex lesions such as ostial, bifurcation and LMCA lesions. The use of extra-support guiding catheter, extra-support guidewires and low stent inflation pressure increases the occurrence of LSD. Nevertheless, with increased awareness of LSD and proper treatment, unwanted long-term outcomes can be successfully prevented.

Entities:  

Keywords:  Accordeon; Complication; Concertina effect; Longitudinal stent compression; Longitudinal stent deformation; Percutaneous coronary intervention

Mesh:

Year:  2016        PMID: 27198891     DOI: 10.1007/s10554-016-0905-1

Source DB:  PubMed          Journal:  Int J Cardiovasc Imaging        ISSN: 1569-5794            Impact factor:   2.357


  19 in total

1.  2011 ACCF/AHA/SCAI Guideline for Percutaneous Coronary Intervention. A report of the American College of Cardiology Foundation/American Heart Association Task Force on Practice Guidelines and the Society for Cardiovascular Angiography and Interventions.

Authors:  Glenn N Levine; Eric R Bates; James C Blankenship; Steven R Bailey; John A Bittl; Bojan Cercek; Charles E Chambers; Stephen G Ellis; Robert A Guyton; Steven M Hollenberg; Umesh N Khot; Richard A Lange; Laura Mauri; Roxana Mehran; Issam D Moussa; Debabrata Mukherjee; Brahmajee K Nallamothu; Henry H Ting
Journal:  J Am Coll Cardiol       Date:  2011-11-07       Impact factor: 24.094

2.  Stent longitudinal integrity bench insights into a clinical problem.

Authors:  John A Ormiston; Bruce Webber; Mark W I Webster
Journal:  JACC Cardiovasc Interv       Date:  2011-11-30       Impact factor: 11.195

3.  Longitudinal stent deformation: a retrospective analysis of frequency and mechanisms.

Authors:  Paul D Williams; Mamas A Mamas; Kenneth P Morgan; Magdi El-Omar; Bernard Clarke; Anthony Bainbridge; Farzin Fath-Ordoubadi; Douglas G Fraser
Journal:  EuroIntervention       Date:  2012-06-20       Impact factor: 6.534

4.  Longitudinal compression: a "new" complication with modern coronary stent platforms--time to think beyond deliverability?

Authors:  Colm G Hanratty; Simon J Walsh
Journal:  EuroIntervention       Date:  2011-11       Impact factor: 6.534

5.  Comparison of zotarolimus-eluting and everolimus-eluting coronary stents.

Authors:  Patrick W Serruys; Sigmund Silber; Scot Garg; Robert Jan van Geuns; Gert Richardt; Pawel E Buszman; Henning Kelbaek; Adrianus Johannes van Boven; Sjoerd H Hofma; Axel Linke; Volker Klauss; William Wijns; Carlos Macaya; Philippe Garot; Carlo DiMario; Ganesh Manoharan; Ran Kornowski; Thomas Ischinger; Antonio Bartorelli; Jacintha Ronden; Marco Bressers; Pierre Gobbens; Manuela Negoita; Frank van Leeuwen; Stephan Windecker
Journal:  N Engl J Med       Date:  2010-06-16       Impact factor: 91.245

6.  Incidence and mechanisms of longitudinal stent deformation associated with Biomatrix, Resolute, Element, and Xience stents: Angiographic and case-by-case review of 1,800 PCIs.

Authors:  Samer Arnous; Nizar Shakhshir; Andrew Wiper; Farzin-Farth Ordoubadi; Paul Williams; Bernard Clarke; Vaikom Mahadavan; Magdi El-Omar; Mamas Mamas; Douglas Fraser
Journal:  Catheter Cardiovasc Interv       Date:  2015-04-24       Impact factor: 2.692

7.  Longitudinal stent deformation: quantitative coronary angiographic analysis from the PERSEUS and PLATINUM randomised controlled clinical trials.

Authors:  Dean J Kereiakes; Jeffrey J Popma; Louis A Cannon; David E Kandzari; Carey D Kimmelstiel; Ian T Meredith; Paul S Teirstein; Stefan Verheye; Dominic J Allocco; Keith D Dawkins; Gregg W Stone
Journal:  EuroIntervention       Date:  2012-06-20       Impact factor: 6.534

8.  Longitudinal stent shortening: the long and short of it!!

Authors:  Ashok Seth; Aseem Dhall
Journal:  Catheter Cardiovasc Interv       Date:  2013-04       Impact factor: 2.692

9.  Longitudinal deformation of contemporary coronary stents: an integrated analysis of clinical experience and observations from the bench.

Authors:  Mohamed Abdel-Wahab; Dmitriy S Sulimov; Guido Kassner; Volker Geist; Ralph Toelg; Gert Richardt
Journal:  J Interv Cardiol       Date:  2012-09-28       Impact factor: 2.279

10.  A prospective, randomized evaluation of a novel everolimus-eluting coronary stent: the PLATINUM (a Prospective, Randomized, Multicenter Trial to Assess an Everolimus-Eluting Coronary Stent System [PROMUS Element] for the Treatment of Up to Two de Novo Coronary Artery Lesions) trial.

Authors:  Gregg W Stone; Paul S Teirstein; Ian T Meredith; Bruno Farah; Christophe L Dubois; Robert L Feldman; Joseph Dens; Nobuhisa Hagiwara; Dominic J Allocco; Keith D Dawkins
Journal:  J Am Coll Cardiol       Date:  2011-04-04       Impact factor: 24.094

View more
  6 in total

1.  The potential hazard of a non-slip element balloon causing distal longitudinal stent deformation: the first clinical experience and in vitro assessment.

Authors:  Hiroki Shibutani; Yuzo Akita; Yohei Oishi; Hiroyuki Sueyoshi; Yu Mukai; Kotaro Yutaka; Yumie Matsui; Masahiro Yoshinaga; Masahiro Karakawa
Journal:  Cardiol J       Date:  2018-06-20       Impact factor: 2.737

2.  Stent accordion phenomenon visualized with optical coherence tomography.

Authors:  Lucky R Cuenza; Khung Keong Yeo
Journal:  Cardiovasc Diagn Ther       Date:  2017-12

3.  Longitudinal Stent Deformation in Undeployed Stents: A Case Series.

Authors:  Parminder Singh Otaal; Dinakar Bootla
Journal:  J Tehran Heart Cent       Date:  2021-07

4.  A catastrophic nightmare of the interventional cardiologist: Iatrogenic left main artery dissection and longitudinal stent deformation.

Authors:  Oguz Yıldırım; Murat Gul; Sinan Inci; Halil Aktaş; Pınar Dogan; Abdulkadir Bozkır; İbrahim İzgü; Recep Karataş
Journal:  Intractable Rare Dis Res       Date:  2018-08

5.  Cardiovascular imaging 2016 in the International Journal of Cardiovascular Imaging.

Authors:  Johan H C Reiber; Johan De Sutter; Paul Schoenhagen; Arthur E Stillman; Nico R L Vande Veire
Journal:  Int J Cardiovasc Imaging       Date:  2017-06       Impact factor: 2.357

6.  Thin and crush: The new mantra in left main stenting?

Authors:  Gianluca Rigatelli; Marco Zuin; Debradata Dash
Journal:  World J Cardiol       Date:  2018-11-26
  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.