Literature DB >> 22445912

Longitudinal stent deformation: quantitative coronary angiographic analysis from the PERSEUS and PLATINUM randomised controlled clinical trials.

Dean J Kereiakes1, Jeffrey J Popma, Louis A Cannon, David E Kandzari, Carey D Kimmelstiel, Ian T Meredith, Paul S Teirstein, Stefan Verheye, Dominic J Allocco, Keith D Dawkins, Gregg W Stone.   

Abstract

AIMS: Recent reports have suggested susceptibility of novel thin-strut coronary stents to incur longitudinal stent deformation during or following deployment. This analysis assesses the incidence of longitudinal stent deformation in three stent platforms. METHODS AND
RESULTS: Quantitative angiographic analysis (QCA) of 2,403 stents from the PERSEUS Workhorse (WH) and PLATINUM-WH trials was performed by an independent core laboratory. The distribution of QCA measured: nominal stent length ratios was compared between platforms to evaluate longitudinal stent deformation. Stent length ratio averaged 0.95 ± 0.07 in the TAXUS Express arm and 0.94 ± 0.06 in the ION (TAXUS Element) arm of the PERSEUS-WH trial (p=0.16). In the PLATINUM-WH trial, the mean ratio in the PROMUS cohort was slightly smaller (0.92 ± 0.09) than PROMUS Element (0.94 ± 0.08; p=0.004). Manual, blinded re-examination by the core laboratory of the angiograms corresponding to the 20 lowest and highest ratios in each trial did not identify any cases of stent deformation.
CONCLUSIONS: Systematic analysis by an independent angiographic core laboratory of 2,403 stents implanted in patients enrolled in two large multicentre randomised trials demonstrated no stent deformation or meaningful differences in stent length ratios between ION and TAXUS Express or between PROMUS Element and PROMUS in the patient populations studied using the methodology employed.

Entities:  

Mesh:

Year:  2012        PMID: 22445912     DOI: 10.4244/EIJV8I2A32

Source DB:  PubMed          Journal:  EuroIntervention        ISSN: 1774-024X            Impact factor:   6.534


  5 in total

1.  Clinical, angiographic and procedural characteristics of longitudinal stent deformation.

Authors:  A Guler; Y Guler; E Acar; S M Aung; S C Efe; A Kilicgedik; C Y Karabay; S Barutcu; M K Tigen; S Pala; A İzgi; A M Esen; C Kirma
Journal:  Int J Cardiovasc Imaging       Date:  2016-05-19       Impact factor: 2.357

2.  Coronary stent concertina in proximal left anterior descending artery: An unusual case.

Authors:  Shivanand Patil; Natraj Setty; Rangaraj Ramalingam; Jayashree Kharge; Cholenahally Nanjappa Manjunath
Journal:  Interv Med Appl Sci       Date:  2017-06

3.  A novel platinum chromium everolimus-eluting stent for the treatment of coronary artery disease.

Authors:  Johan Bennett; Christophe Dubois
Journal:  Biologics       Date:  2013-06-19

Review 4.  Clinical utility of platinum chromium bare-metal stents in coronary heart disease.

Authors:  Claudia Jorge; Christophe Dubois
Journal:  Med Devices (Auckl)       Date:  2015-08-27

5.  Bare metal stents, durable polymer drug eluting stents, and biodegradable polymer drug eluting stents for coronary artery disease: mixed treatment comparison meta-analysis.

Authors:  Sripal Bangalore; Bora Toklu; Nicholas Amoroso; Mario Fusaro; Sunil Kumar; Edward L Hannan; David P Faxon; Frederick Feit
Journal:  BMJ       Date:  2013-11-08
  5 in total