Evaluating Innovative In-Ear Pulse Oximetry for Unobtrusive Cardiovascular and Pulmonary Monitoring During Sleep.

Boudewijn Venema1, Johannes Schiefer2, Vladimir Blazek1, Nikolai Blanik1, Steffen Leonhardt1.   

Abstract

Homecare is healthcare based on the principle "outpatient before inpatient," with the aim of moving at least some care-delivery to the home. But reliable determination of vital signs at home requires new, smart sensors, which can be used by the patients themselves. We present a novel pulse oximetry sensor worn in the ear channel. It was previously shown that measurement of heart rate, arterial oxygen saturation and related respiratory information can be performed with reliable accuracy under laboratory conditions. The present study explores the clinical feasibility of the sensor system for cardiovascular monitoring during sleep, with the aim to diagnose sleep apnea. For this, human trials were performed in a sleep laboratory including patients with a clinical suspicion of sleep apnea. Besides a general analysis of the sensor's signal quality during sleep, the evaluation focuses on heart rate dynamics and time-variant oxygen saturation. In addition, several methods to derive respiration rate from photoplethysmographic signals are examined and discussed. Results from the in-ear sensor are compared with standard polysomnography monitoring and demonstrate that this novel system allows long-term nocturnal measurement of heart rate, oxygen saturation and respiratory rate with sufficient accuracy.

Entities:  

Keywords:  Photoplethysmography (PPG); blood volume dynamics; oxygen saturation; pulse oximetry; sleep apnea

Year:  2013        PMID: 27170855      PMCID: PMC4819232          DOI: 10.1109/JTEHM.2013.2277870

Source DB:  PubMed          Journal:  IEEE J Transl Eng Health Med        ISSN: 2168-2372            Impact factor:   3.316


  13 in total

1.  The effects of motion artifact and low perfusion on the performance of a new generation of pulse oximeters in volunteers undergoing hypoxemia.

Authors:  Hartmut Gehring; Christoph Hornberger; Holger Matz; Ewald Konecny; Peter Schmucker
Journal:  Respir Care       Date:  2002-01       Impact factor: 2.258

Review 2.  Respiratory sinus arrhythmia: why does the heartbeat synchronize with respiratory rhythm?

Authors:  Fumihiko Yasuma; Jun-Ichiro Hayano
Journal:  Chest       Date:  2004-02       Impact factor: 9.410

3.  Neural network for photoplethysmographic respiratory rate monitoring.

Authors:  A Johansson
Journal:  Med Biol Eng Comput       Date:  2003-05       Impact factor: 2.602

4.  Decreased accuracy of pulse oximetry measurements during low perfusion caused by sepsis: Is the perfusion index of any value?

Authors:  Helmut D Hummler; Anja Engelmann; Frank Pohlandt; Josef Högel; Axel R Franz
Journal:  Intensive Care Med       Date:  2006-06-30       Impact factor: 17.440

5.  Counterpoint: respiratory sinus arrhythmia is due to the baroreflex mechanism.

Authors:  John M Karemaker
Journal:  J Appl Physiol (1985)       Date:  2009-05

6.  In-ear vital signs monitoring using a novel microoptic reflective sensor.

Authors:  Stefan Vogel; Markus Hülsbusch; Thomas Hennig; Vladimir Blazek; Steffen Leonhardt
Journal:  IEEE Trans Inf Technol Biomed       Date:  2009-10-20

7.  Pulse oximetry and circulatory kinetics associated with pulse volume amplitude measured by photoelectric plethysmography.

Authors:  J M Kim; K Arakawa; K T Benson; D K Fox
Journal:  Anesth Analg       Date:  1986-12       Impact factor: 5.108

8.  Evaluating Innovative In-Ear Pulse Oximetry for Unobtrusive Cardiovascular and Pulmonary Monitoring During Sleep.

Authors:  Boudewijn Venema; Johannes Schiefer; Vladimir Blazek; Nikolai Blanik; Steffen Leonhardt
Journal:  IEEE J Transl Eng Health Med       Date:  2013-08-08       Impact factor: 3.316

9.  Nocturnal oximetry for the diagnosis of the sleep apnoea hypopnoea syndrome: a method to reduce the number of polysomnographies?

Authors:  E Chiner; J Signes-Costa; J M Arriero; J Marco; I Fuentes; A Sergado
Journal:  Thorax       Date:  1999-11       Impact factor: 9.139

10.  Characteristics of the snoring noise in patients with and without occlusive sleep apnea.

Authors:  J R Perez-Padilla; E Slawinski; L M Difrancesco; R R Feige; J E Remmers; W A Whitelaw
Journal:  Am Rev Respir Dis       Date:  1993-03
View more
  5 in total

1.  Evaluating Innovative In-Ear Pulse Oximetry for Unobtrusive Cardiovascular and Pulmonary Monitoring During Sleep.

Authors:  Boudewijn Venema; Johannes Schiefer; Vladimir Blazek; Nikolai Blanik; Steffen Leonhardt
Journal:  IEEE J Transl Eng Health Med       Date:  2013-08-08       Impact factor: 3.316

2.  The Effect of Optical Crosstalk on Accuracy of Reflectance-Type Pulse Oximeter for Mobile Healthcare.

Authors:  Hyun Jae Baek; JaeWook Shin; Jaegeol Cho
Journal:  J Healthc Eng       Date:  2018-10-21       Impact factor: 2.682

3.  Can pulse check by the photoplethysmography sensor on a smart watch replace carotid artery palpation during cardiopulmonary resuscitation in cardiac arrest patients? a prospective observational diagnostic accuracy study.

Authors:  Yoonje Lee; Hyungoo Shin; Hyuk Joong Choi; Changsun Kim
Journal:  BMJ Open       Date:  2019-02-19       Impact factor: 2.692

Review 4.  Sensor Fusion and Smart Sensor in Sports and Biomedical Applications.

Authors:  José Jair Alves Mendes; Mário Elias Marinho Vieira; Marcelo Bissi Pires; Sergio Luiz Stevan
Journal:  Sensors (Basel)       Date:  2016-09-23       Impact factor: 3.576

5.  Investigation of Photoplethysmography Behind the Ear for Pulse Oximetry in Hypoxic Conditions with a Novel Device (SPYDR).

Authors:  Brian Bradke; Bradford Everman
Journal:  Biosensors (Basel)       Date:  2020-04-04
  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.