PURPOSE: To compare the visual performance of prototype contact lenses which extend depth-of-focus (EDOF) by deliberate manipulation of multiple higher-order spherical aberration terms and a commercially-available center-near lens (AIR OPTIX Aqua Multifocal, AOMF).Entities:
Keywords: Aberraciones de alto orden; Desempeño visual; Extended depth of focus contact lenses; Higher order aberrations; Lentes de contacto con profundidad de campo extendida; Lentillas multifocales; Multifocal contact lenses; Presbicia; Presbyopia; Visual performance
Mesh:
Year: 2016 PMID: 27161603 PMCID: PMC5219826 DOI: 10.1016/j.optom.2016.04.003
Source DB: PubMed Journal: J Optom ISSN: 1989-1342
Presbyopic strata and near power used for each lens type. The near add calculated at baseline was used to stratify participants as low, medium and presbyopes and to determine near power for both lens types.
| Near add (D) | Presbyopia strata | EDOF | AOMF | |
|---|---|---|---|---|
| Dominant eye | Non-dominant eye | Both eyes | ||
| ≤1.25 | Low | Low | Low | Low |
| +1.50 to +1.75 | Medium | Low | High | Medium |
| ≥+2.00 | High | High | High | High |
EDOF, extended depth of focus; AOMF, AIR OPTIX aqua Multifocal.
Participants with +2.00 near add were stratified as high presbyopes but wore AOMF-medium in both eyes as per manufacturer's recommendation
Parameters and physical properties of contact lenses used in this trial.
| Parameter | EDOF | AOMF |
|---|---|---|
| Base curve, mm | 8.4 | 8.6 |
| Diameter, mm | 14.0 | 14.2 |
| Power range, D (Steps) | −6.00 to +3.00 (0.50) | −6.00 to +3.00 (0.25) |
| Near power | Low, high | Low, medium, high |
| Material (%) | Poly-HEMA-based (42) | Lotrafilcon B (67) |
| Material class | Hydrogel | Silicone-hydrogel |
| Water content, % | 58 | 33 |
| Dk, ×10−11 (cm2 × ml O2)/(sec × ml × mmHg) | 17 | 110 |
| Modulus, MPa | 0.4 | 1.0 |
| Packaging solution | Borate buffered saline | Buffered saline containing 1% Copolymer 845 |
| FDA group | 4 | 1 |
| Manufacturer | Brien Holden Vision Pty Ltd., Australia | Alcon Laboratories, USA |
EDOF, extended depth of focus; AOMF, AIR OPTIX aqua Multifocal; Dk, oxygen permeability.
Figure 1The power profiles of the AOMF (low and high add) and EDOF (low and high power) with distance power plano for all lenses. Power profiles were measured using the NIMO TR1504 (Lambda-X, Belgium).
Demographic factors for low and medium-high presbyopes.
| Low presbyopes | Medium-high presbyopes | ||
|---|---|---|---|
| Age, years | 49 ± 3 | 57 ± 6 | |
| Age range, years | 45–56 | 47–70 | – |
| Gender, % | 0.278 | ||
| Female:Male | 57:44 | 41:59 | |
| Ethnicity, % | 0.204 | ||
| Caucasian:Asian:others | 61:13:26 | 83:7:10 | |
| Lens wear experience, % | 0.400 | ||
| Experienced wearers: non-lens wearers | 65:35 | 76:24 | |
| Keratometry:Flat Power, D | 43.5 ± 1.4 | 43.1 ± 1.4 | 0.323 |
| Keratometry:Steep Power, D | 44.1 ± 1.5 | 43.7 ± 1.5 | 0.317 |
| Low presbyopes | Medium-high presbyopes | ||
| Refraction:Spherical Equivalent, D | −2.6 ± 1.3 | −2.5 ± 1.5 | 0.693 |
| Low presbyopes | Medium-high presbyopes | ||
| Refraction:Spherical Equivalent, D | +1.2 ± 0.4 | +1.4 ± 0.6 | 0.274 |
Data expressed as mean ± SD.
Results presented for both eyes combined.
Does not sum to 100 due to rounding.
Objective measurements while wearing EDOF and AOMF lenses. HCVA at 70 cm, 50 cm and 40 cm are measures of “comfortable acuity” rather than conventional resolution acuity. Descriptive data only is provided for low and medium-high presbyopes as there was no significant interaction between lens type and participant strata (p = 0.676). p-values in bold and italicized indicate significant differences between lens types.
| Variable | Distance measured | EDOF | AOMF | ||
|---|---|---|---|---|---|
| Mean ± SD | Mean ± SD | ||||
| Presbyopes combined | HCVA | 6 m | −0.06 ± 0.05 | −0.06 ± 0.05 | 0.915 |
| LCVA | 6 m | 0.24 ± 0.09 | 0.25 ± 0.10 | 0.356 | |
| CS | 6 m | 1.0 ± 0.2 | 0.9 ± 0.2 | 0.642 | |
| HCVA | 70 cm | 0.12 ± 0.11 | 0.13 ± 0.14 | 0.622 | |
| HCVA | 50 cm | 0.26 ± 0.17 | 0.30 ± 0.18 | 0.169 | |
| HCVA | 40 cm | 0.42 ± 0.18 | 0.48 ± 0.22 | ||
| Stereopsis | 40 cm | 98 ± 88 | 141 ± 114 | ||
| Low presbyopes | HCVA | 6 m | −0.07 ± 0.04 | −0.08 ± 0.03 | – |
| LCVA | 6 m | 0.21 ± 0.10 | 0.19 ± 0.08 | – | |
| CS | 6 m | 1.0 ± 0 2 | 1.1 ± 0 2 | – | |
| HCVA | 70 cm | 0.08 ± 0.11 | 0.12 ± 0.14 | – | |
| HCVA | 50 cm | 0.25 ± 0.21 | 0.31 ± 0.20 | – | |
| HCVA | 40 cm | 0.41 ± 0.21 | 0.48 ± 0.21 | – | |
| Stereopsis | 40 cm | 93 ± 75 | 124 ± 100 | – | |
| Medium–high presbyopes | HCVA | 6 m | −0.05 ± 0.05 | −0.03 ± 0.06 | – |
| LCVA | 6 m | 0.25 ± 0.07 | 0.30 ± 0.08 | – | |
| CS | 6 m | 0.9 ± 0.2 | 0.9 ± 0.2 | – | |
| HCVA | 70 cm | 0.14 ± 0.11 | 0.13 ± 0.14 | – | |
| HCVA | 50 cm | 0.27 ± 0.14 | 0.30 ± 0.17 | – | |
| HCVA | 40 cm | 0.43 ± 0.15 | 0.49 ± 0.24 | – | |
| Stereopsis | 40 cm | 102 ± 98 | 155 ± 125 | – |
HCVA, high-contrast visual acuity; LC, low-contrast visual acuity; CS, contrast sensitivity; EDOF, extended depth of focus; AOMF, AIR OPTIX aqua Multifocal. Units of measurement: HC VA = log MAR, LC VA = log MAR, CS = log units (18 cycles/degree), stereopsis = seconds of arc.
Figure 2Clarity-of-vision (distance, intermediate, and near), overall vision satisfaction and comfort overall ratings while wearing EDOF and AOMF lenses for presbyopes combined. Error bars = 1 SD. *p = 0.471, †p = 0.006, ‡p = 0.005, §p < 0.001, ¥p = 0.002
Figure 3Lack-of-ghosting ratings while wearing EDOF and AOMF lenses for presbyopes combined at distance, intermediate and near. There was a significant difference between lens types for lack-of-ghosting (p = 0.012) but no significant interaction between lens type and testing distance (p = 0.126). Error bars = 1 SD.
Figure 4Proportion of presbyopes combined who rated clarity-of-vision ≥ 8 units for all three testing distance (distance, intermediate and near) and overall vision satisfaction ≥ 8 units while wearing EDOF and AOMF lenses. *p = 0.022, †p = 0.002.
Subjective ratings while wearing EDOF and AOMF lenses for low and medium-high presbyopes. Descriptive data only provided as there was no significant interaction between lens type and participant strata for clarity-of-vision (p = 0.119) or lack-of-ghosting (p = 0.276). Higher ratings represent a better outcome.
| Variable | EDOF | AOMF | ||
|---|---|---|---|---|
| Mean ± SD | Mean ± SD | |||
| Low presbyopes | Clarity-of-Vision | Distance | 8.4 ± 1.3 | 8.6 ± 1.1 |
| Intermediate | 8.8 ± 1.3 | 8.1 ± 2.1 | ||
| Near | 7.7 ± 2.3 | 6.5 ± 2.6 | ||
| Lack-of-Ghosting | Distance | 9.5 ± 0.7 | 9.6 ± 0.6 | |
| Intermediate | 9.6 ± 0.7 | 8.8 ± 2.0 | ||
| Near | 9.3 ± 0.9 | 8.7 ± 2.0 | ||
| Overall Vision Satisfaction | 7.7 ± 1.6 | 7.2 ± 2.1 | ||
| Overall Comfort | 9.1 ± 0.9 | 8.6 ± 1.6 | ||
| Medium–high presbyopes | Clarity-of-Vision | Distance | 6.9 ± 2.1 | 7.1 ± 1.9 |
| Intermediate | 8.3 ± 1.8 | 7.4 ± 1.6 | ||
| Near | 6.9 ± 2.7 | 6.0 ± 2.5 | ||
| Lack-of-Ghosting | Distance | 8.7 ± 1.5 | 8.5 ± 1.8 | |
| Intermediate | 9.0 ± 1.2 | 8.5 ± 1.8 | ||
| Near | 8.7 ± 1.4 | 8.1 ± 1.8 | ||
| Overall Vision Satisfaction | 7.3 ± 1.9 | 5.7 ± 2.1 | ||
| Overall Comfort | 8.9 ± 1.1 | 8.1 ± 1.7 |
EDOF, extended depth of focus; AOMF, AIR OPTIX aqua Multifocal.
Figure 5Lens purchase results while wearing EDOF and AOMF lenses for presbyopes combined. The p-value refers to participants willing to purchases EDOF only (33%) vs. AOMF only (6%).
Lens fitting parameters for EDOF and AOMF lenses for all presbyopes combined.
| Variable | EDOF | AOMF | ||
|---|---|---|---|---|
| Mean ± SD | Mean ± SD | |||
| Presbyopes combined | Horizontal Centration (mm) | 0.01 ± 0.26 | −0.03 ± 0.08 | 0.279 |
| Vertical Centration (mm) | −0.01 ± 0.06 | −0.02 ± 0.06 | 0.563 | |
| Primary Gaze Movement (mm) | 0.16 ± 0.09 | 0.18 ± 0.10 | 0.309 | |
| Primary Gaze Lag (mm) | 0.10 ± 0.08 | 0.09 ± 0.07 | 0.210 | |
| Tightness (%) | 47.6 ± 6.4 | 48.5 ± 6.7 | 0.419 |
EDOF, extended depth of focus; AOMF, AIR OPTIX aqua Multifocal.
Positive values indicates nasal decentration. Negative values indicates temporal decentration.
Positive values indicates superior decentration. Negative values indicates inferior decentration.