Danny Kho1, Cathleen Fedtke1,2, Daniel Tilia1,2, Jennie Diec1, Jennifer Sha1, Varghese Thomas1, Ravi C Bakaraju1,2.
Abstract
OBJECTIVE: The study aimed to compare the visual performance of contact lenses with and without negative spherical aberration (SA) over 5 days of wear.Entities:
Keywords: power profile; soft contact lens; spherical aberration; visual acuity
Year: 2018 PMID: 30214337 PMCID: PMC6095571 DOI: 10.2147/OPTO.S142952
Source DB: PubMed Journal: Clin Optom (Auckl) ISSN: 1179-2752
Figure 1Average power profiles of study lenses with labeled back vertex powers of −1.00, −3.00, and −6.00 D using the NIMO TR1504 across a 3.5 mm half chord.
Note: Average values were calculated from a minimum of three lenses (maximum of five) for each nominal power.
Comparison of the mean power and SD across 1 and 3.5 mm half chord for 1-Day Acuvue Moist and test contact lenses
| Contact lens | Nominal power (D) | 1 mm half chord
| 3.5 mm half chord
| ||
|---|---|---|---|---|---|
| Mean (D) | SD (D) | Mean (D) | SD (D) | ||
| 1 Day Acuvue Moist | −1.00 | −1.14 | 0.08 | −1.31 | 0.18 |
| −3.00 | −3.19 | 0.07 | −3.43 | 0.26 | |
| −6.00 | −6.29 | 0.08 | −6.58 | 0.47 | |
| Test lens | −1.00 | −1.21 | 0.07 | −1.21 | 0.04 |
| −3.00 | −3.01 | 0.09 | −2.99 | 0.06 | |
| −6.00 | −6.09 | 0.09 | −5.94 | 0.12 | |
Note: Average and SD values were calculated from a minimum of three lenses (maximum of five) for each nominal power measured with the NIMO TR1504.
Comparison of lens fit characteristics for study lenses at the Fitting Visit
| Contact lens fit variable | Lens | Mean | SD | ||
|---|---|---|---|---|---|
| Centration (mm) | Horizontal | 1-DAM | −0.06 | 0.12 | 0.072 |
| Test | −0.04 | 0.08 | |||
| Vertical | 1-DAM | −0.09 | 0.18 | < | |
| Test | 0.02 | 0.09 | |||
| Primary gaze lens lag (mm) | 1-DAM | 0.20 | 0.10 | < | |
| Test | 0.15 | 0.08 | |||
| Primary gaze lens movement (mm) | 1-DAM | 0.27 | 0.09 | < | |
| Test | 0.19 | 0.06 | |||
| Lens fit tightness (%) | 1-DAM | 42.8 | 7.9 | ||
| Test | 46.6 | 7.2 | |||
Notes: For centration measurements, positive values indicate nasal or superior directions while negative values indicate temporal or inferior directions. Overall lens fit grades are based on a 0–4 scale, where a grade of 2 or higher indicates a clinically acceptable lens fit. Bold represents statistically significant values (p<0.05).
Abbreviation: 1-DAM, 1-Day Acuvue Moist.
On-axis mean SA and SD for unaided (no lens wear) eye, while wearing 1-DAM and test lenses for 6 mm pupil size
| Vergence demand | Lens | Mean SA (μm) | SD | Post hoc analysis
| |||
|---|---|---|---|---|---|---|---|
| Unaided | 1-DAM | Test lens | |||||
| Distance (−1 D) | Unaided | 0.007 | 0.13 | < | – | < | 1.00 |
| 1-DAM | −0.063 | 0.10 | < | – | < | ||
| Test | 0.015 | 0.10 | 1.00 | < | – | ||
| Near (+3 D) | 1-DAM | −0.155 | 0.12 | < | – | ||
| Test | −0.091 | 0.12 | |||||
Note: Bold represents statistically significant values (p<0.05).
Abbreviations: 1-DAM, 1-Day Acuvue Moist; SA, spherical aberration.
Figure 2On-axis spherical aberration expressed in D/mm2 for unaided, test lens, and 1-DAM at distance (−1.00 D demand) and near (+3.00 D demand).
Abbreviation: 1-DAM, 1-Day Acuvue Moist.
Mean objective visual performance measures (n=32) and SD
| Variable | Distance (m) | 1-DAM
| Test lens
| |
|---|---|---|---|---|
| Mean ± SD | Mean ± SD | |||
| High-illumination HCVA (logMAR) | 6.00 | −0.14±0.07 | −0.14±0.06 | 0.288 |
| 0.70 | −0.12±0.07 | −0.12±0.06 | ||
| 0.40 | −0.11±0.06 | −0.12±0.06 | ||
| High-illumination LCVA (logMAR) | 6.00 | 0.10±0.08 | 0.10±0.07 | 0.683 |
| 0.70 | 0.00±0.06 | −0.01±0.06 | ||
| 0.40 | 0.05±0.06 | 0.03±0.07 | ||
| Low-illumination LCVA (logMAR) | 6.00 | 0.15±0.08 | 0.17±0.09 | 0.145 |
| Horizontal heterophoria | 3.00 | −0.31±0.74 | −0.34±0.74 | 0.597 |
| 0.33 | −1.25±2.48 | −0.97±3.44 | 0.145 | |
| Accommodative facility (cycles/min) | 0.33 | 14.5±5.2 | 13.9±4.4 | 0.363 |
| Near stereopsis (seconds of arc) | 0.40 | 19±7 | 19±10 | 0.989 |
Notes: p-values are based on a linear mixed model with lens type as a factor. For HCVA and LCVA, p-values for visual acuities examine for overall differences between lens types at all distances tested.
Positive values = esophoria, negative values = exophoria.
Abbreviations: 1-DAM, 1-Day Acuvue Moist; HCVA, high-contrast visual acuity; LCVA, low-contrast visual acuity.
Comparison of subjective visual performance mean and SD between 1-DAM and test lens
| Variable | Time of day | Viewing distance | 1-DAM
| Test lens
| |
|---|---|---|---|---|---|
| Mean ± SD | Mean ± SD | ||||
| Vision clarity | Daytime | Distance | 8.8±1.0 | 8.6±1.0 | 0.614 |
| Intermediate | 8.8±1.2 | 8.9±1.2 | |||
| Near | 8.8±1.0 | 8.8±1.3 | |||
| Night-time | Distance | 8.5±1.2 | 8.2±1.2 | ||
| Intermediate | 8.5±1.3 | 8.4 ±1.3 | |||
| Near | 8.4±1.4 | 8.5±1.3 | |||
| Lack of ghosting | Daytime | Distance | 9.4±1.1 | 9.3±1.1 | 0.553 |
| Intermediate | 9.3±0.9 | 9.4±0.9 | |||
| Near | 9.4±0.9 | 9.5±0.8 | |||
| Night-time | Distance | 9.2±1.2 | 9.2±1.0 | ||
| Intermediate | 9.3±1.0 | 9.3±0.9 | |||
| Near | 9.3±0.9 | 9.5±0.7 | |||
| Driving vision | Daytime | 8.9 ±0.9 | 8.6±1.1 | 0.529 | |
| Night-time | 8.3±1.3 | 8.4±0.9 | |||
| Vision stability | Daytime | 8.2±1.4 | 8.4±1.3 | ||
| Night-time | 8.0±1.4 | 8.3±1.2 | |||
| Night-time halo appearance | 9.2±1.8 | 9.7±0.7 | 0.162 | ||
| Overall vision satisfaction | 8.0±1.3 | 8.3±1.5 | 0.399 | ||
| Ocular comfort | 7.4±2.0 | 8.1±1.7 | 0.082 |
Notes: Ratings are based on a 1–10 numeric rating scale where higher scores indicate better outcomes. Bold represents statistically significant values (p<0.05).
Abbreviation: 1-DAM, 1-Day Acuvue Moist.