Ravi C Bakaraju1, Klaus Ehrmann2, Arthur Ho2.
Abstract
PURPOSE: To compare the computed optical performance of prototype lenses designed using deliberate manipulation of higher-order spherical aberrations to extend depth-of-focus (EDOF) with two commercial multifocals.Entities:
Keywords: Aberraciones de alto orden; Extended depth of focus contact lenses; Fourier Optics; Higher order aberrations; Lentes de contacto de profundidad de campo ampliada; Presbicia; Presbyopia; Ray tracing simulation; Simulación de trazado de rayos; Óptica de Fourier
Mesh:
Year: 2017 PMID: 28606456 PMCID: PMC5777930 DOI: 10.1016/j.optom.2017.04.003
Source DB: PubMed Journal: J Optom ISSN: 1989-1342
Figure 1Power profiles of the study lenses. Units of the color scale is in Diopters (D). L: Low; M: Medium; H: High add power.
Figure 2Log transformed through password-focus retinal image quality values computed as a function of 5 pupil diameters: from 3 to 5 mm in 0.5 mm steps. This data represents computations performed on the schematic eye embedded with Model 2 inherent aberrations. The correcting lens was well-centered over the cornea. A red dashed line across subgraphs indicates the ideal threshold RIQ. The bounded area under the perpendicular lines drawn from X-axis (absolute value) is inscribed at the corner of each sub-graphs indicate the variance of TFRIQ between the five pupil diameters.
Figure 3Log transformed through-focus retinal image quality values computed as a function of 3 inherent aberration models: Models 1–3. This data represents computations performed on the schematic eye with 4 mm pupil. The correcting lens was well-centered over the cornea. A red dashed line across sub-graphs indicates the ideal threshold RIQ. The bounded area under the perpendicular lines drawn from X-axis (absolute value) is inscribed at the corner of each sub-graphs indicate the variance of TFRIQ between the three aberration models.
Figure 4Log transformed through-focus retinal image quality values computed as a function of 5 preset lens centration positions: 0.0–0.50 mm in 0.125 mm steps. This data represents computations performed on the schematic eye embedded with Model 2 inherent aberrations (excluding asymmetric HOA) at 3.5 mm pupil diameter. A red dashed line across sub-graphs indicates the ideal threshold RIQ. The bounded area under the perpendicular lines drawn from X-axis (absolute value) is inscribed at the corner of each sub-graphs indicate the variance of TFRIQ between the five decentration levels.