Optimizing contrast media application in coronary CT angiography at lower tube voltage: Evaluation in a circulation phantom and sixty patients.

Madeleine Kok1, Casper Mihl2, Babs M F Hendriks3, Sibel Altintas4, Bas L J H Kietselaer5, Joachim E Wildberger6, Marco Das7.   

Abstract

PURPOSE: The purpose was to investigate optimal contrast media (CM) injection parameters for lower kVp settings, whilst maintaining diagnostic attenuation levels. METHODS AND MATERIALS: First, a circulation phantom with physiological parameters (BP 120/80mmHg, HR 60bpm) was used. A fixed CM injection protocol was used for each kVp setting (300mgI/ml [Iopromide], volume=45ml, flow rate=6.0ml/s, iodine delivery rate [IDR]=1.8gI/s, iodine load=13.5gI; at 120, 100, 80 and 70kVp). Then, IDR was decreased by steps of 0.2gI/s for each kVp setting, until diagnostically insufficient attenuation values were reached (<325HU). In order to keep injection time constant (7.5s), total iodine load (TIL) was reduced accordingly. Second, clinical applicability at 120 and 100kVp was evaluated in patients (n=60) referred for coronary CT angiography. A standard and reduced (12% less) CM protocol was used based on weight classes and scan duration ('high-pitch': 1s; 'adaptive sequence' and 'helical': 7s). Attenuation levels of the coronary arteries were measured and compared between protocols.
RESULTS: Using a fixed CM injection at each kVp level resulted in the following HU values: 335HU±31 (120kVp); 425HU±30 (100kVp); 587HU±29 (80kVp); 666HU±27 (70kVp). Keeping diagnostic enhancement levels (353HU±28) CM could be reduced as follows: 12% for 100kVp; 45% for 80kVp and 56% for 70kVp. Diagnostic enhancement levels could be reproduced with concurrent CM reduction (-12% at 100kV) in the clinical setting (382HU±35).
CONCLUSION: CM injection parameters can be substantially reduced at low kVp settings (up to 56% at 70kVp), whilst maintaining diagnostic attenuation levels. This may play an important role in CT imaging of the coronary arteries as well as cerebral and peripheral circulations in the future.
Copyright © 2016. Published by Elsevier Ireland Ltd.

Entities:  

Keywords:  Contrast media; Multidetector-row computed tomography; Tube voltage

Mesh:

Substances:

Year:  2016        PMID: 27161054     DOI: 10.1016/j.ejrad.2016.03.022

Source DB:  PubMed          Journal:  Eur J Radiol        ISSN: 0720-048X            Impact factor:   3.528


  16 in total

1.  Reducing both radiation and contrast doses in coronary CT angiography in lean patients on a 16-cm wide-detector CT using 70 kVp and ASiR-V algorithm, in comparison with the conventional 100-kVp protocol.

Authors:  Yuhuan Chen; Zhentang Liu; Michelle Li; Yong Yu; Yongjun Jia; Guangming Ma; Zhijun Hu; DongHong Wei; Dou Li; Taiping He
Journal:  Eur Radiol       Date:  2018-11-30       Impact factor: 5.315

2.  Coronary CT Angiography Using Low Iodine Delivery Rate and Tube Voltage Determined by Body Mass Index: Superiority in Clinical Practice.

Authors:  Wang Yuan; Ting-Ting Qu; Hui-Juan Wang; Mei-Yu Wang; Yuan Qu; Gang Niu; Jian Yang
Journal:  Curr Med Sci       Date:  2019-10-14

3.  Determination of glomerular filtration rate (GFR) from fractional renal accumulation of iodinated contrast material: a convenient and rapid single-kidney CT-GFR technique.

Authors:  XiaoDong Yuan; Wei Tang; WenWei Shi; Libao Yu; Jing Zhang; Qing Yuan; Shan You; Ning Wu; Guokun Ao; Tingting Ma
Journal:  Eur Radiol       Date:  2018-02-09       Impact factor: 5.315

4.  Contrast agent concentration optimization in CTA using low tube voltage and dual-energy CT in multiple vendors: a phantom study.

Authors:  Robbert W van Hamersvelt; Nienke G Eijsvoogel; Casper Mihl; Pim A de Jong; Arnold M R Schilham; Nico Buls; Marco Das; Tim Leiner; Martin J Willemink
Journal:  Int J Cardiovasc Imaging       Date:  2018-03-08       Impact factor: 2.357

5.  Influence of tube potential on quantitative coronary plaque analyses by low radiation dose computed tomography: a phantom study.

Authors:  Chunhong Wang; Yuliang Liao; Haibin Chen; Xin Zhen; Jianhong Li; Yikai Xu; Linghong Zhou
Journal:  Int J Cardiovasc Imaging       Date:  2018-03-26       Impact factor: 2.357

6.  Contrast media injection protocol optimization for dual-energy coronary CT angiography: results from a circulation phantom.

Authors:  Domenico De Santis; Damiano Caruso; U Joseph Schoepf; Marwen Eid; Moritz H Albrecht; Taylor M Duguay; Akos Varga-Szemes; Andrea Laghi; Carlo N De Cecco
Journal:  Eur Radiol       Date:  2018-02-27       Impact factor: 5.315

7.  High-strength deep learning image reconstruction in coronary CT angiography at 70-kVp tube voltage significantly improves image quality and reduces both radiation and contrast doses.

Authors:  Wanjiang Li; Kaiyue Diao; Yuting Wen; Tao Shuai; Yongchun You; Jin Zhao; Kai Liao; Chunyan Lu; Jianqun Yu; Yong He; Zhenlin Li
Journal:  Eur Radiol       Date:  2022-01-21       Impact factor: 5.315

8.  The optimal monoenergetic spectral image level of coronary computed tomography (CT) angiography on a dual-layer spectral detector CT with half-dose contrast media.

Authors:  Xin Huang; Sizhe Gao; Yue Ma; Xiaomei Lu; Zheng Jia; Yang Hou
Journal:  Quant Imaging Med Surg       Date:  2020-03

9.  High-Pitch Coronary CT Angiography at 70 kVp Adopting a Protocol of Low Injection Speed and Low Volume of Contrast Medium.

Authors:  Ruiqi Feng; Jiajie Tong; Xiaofei Liu; Yu Zhao; Liang Zhang
Journal:  Korean J Radiol       Date:  2017-07-17       Impact factor: 3.500

10.  An Individualized Contrast-Enhanced Liver Computed Tomography Imaging Protocol Based on Body Mass Index in 126 Patients Seen for Liver Cirrhosis.

Authors:  Jian Jiang; Maowei Zhang; Yuan Ji; Chunfeng Li; Xin Fang; Shuyuan Zhang; Wei Wang; Lijun Wang; Ailian Liu
Journal:  Med Sci Monit       Date:  2021-06-24
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.