Literature DB >> 27152144

Impact of computed tomography image and contact force technology on catheter ablation for atrial fibrillation.

Ibrahim Marai1, Mahmoud Suleiman1, Miry Blich1, Jonathan Lessick1, Sobhi Abadi1, Monther Boulos1.   

Abstract

AIM: To investigate the impact of using computed tomography (CT) and contact force (CF) technology on recurrence of atrial tachyarrhythmia after atrial fibrillation (AF) ablation.
METHODS: This non-randomized study included 2 groups of patients. All patients had symptomatic recurrent paroxysmal or persistent AF and were treated with at least 1 anti arrhythmic medication or intolerant to medication. The first group included 33 patients who underwent circumferential pulmonary veins isolation (PVI) for AF during 2012 and 2013 guided by CT image integration (Cartomerge, Biosense Webster, Diamond Bar, CA, United States) of left atrium and pulmonary veins into an electroanatomic mapping (EAM) system (CT group) using standard irrigated radiofrequency catheter (ThermoCool, Carto, Biosense Webster, Diamond Bar, CA, United States) or irrigated catheter with integrated CF sensor (Smart Touch, Carto, Biosense Webster, Diamond Bar, CA, United States). The second group included immediately preceding 32 patients who had circumferential PVI by standard irrigated catheter (ThermoCool) using only EAM (Carto) system (EAM group). Linear lesions were performed according to the discretion of operator.
RESULTS: Sex, age, and persistent AF were not different between groups. PVI was achieved in all patients in both groups. Linear ablations including cavo-tricuspid isthmus and or roof line ablation were not different between groups. Free of atrial tachyarrhythmia during follow-up of 24 mo was significantly higher among CT group compared to EAM group (81% vs 55%; respectively; P = 0.027). When 11 patients from CT group who had ablation using Smart Touch catheter were excluded, the difference between CT group and EAM became non significant (73% vs 55%; respectively; P = 0.16). Sub analysis of CT group showed that patients who had ablation using Smart Touch catheter tend to be more free of atrial tachyarrhythmia compared to patients who had ablation using standard irrigated catheter during follow-up (100% vs 73%; respectively; P = 0.07). Major complications (pericardial effusion, cerebrovascular accident/transient ischemic attack, vascular access injury requiring intervention) did not occurred in both groups.
CONCLUSION: These preliminary results suggest that CT image integration and CF technology may reduce the recurrence of atrial tachyarrhythmia after catheter ablation for AF.

Entities:  

Keywords:  Atrial fibrillation; Catheter ablation; Contact force; Image integration

Year:  2016        PMID: 27152144      PMCID: PMC4840165          DOI: 10.4330/wjc.v8.i4.317

Source DB:  PubMed          Journal:  World J Cardiol


  12 in total

1.  Electrical reconnection after pulmonary vein isolation is contingent on contact force during initial treatment: results from the EFFICAS I study.

Authors:  Petr Neuzil; Vivek Y Reddy; Josef Kautzner; Jan Petru; Dan Wichterle; Dipen Shah; Hendrik Lambert; Aude Yulzari; Erik Wissner; Karl-Heinz Kuck
Journal:  Circ Arrhythm Electrophysiol       Date:  2013-03-20

2.  2012 HRS/EHRA/ECAS expert consensus statement on catheter and surgical ablation of atrial fibrillation: recommendations for patient selection, procedural techniques, patient management and follow-up, definitions, endpoints, and research trial design: a report of the Heart Rhythm Society (HRS) Task Force on Catheter and Surgical Ablation of Atrial Fibrillation. Developed in partnership with the European Heart Rhythm Association (EHRA), a registered branch of the European Society of Cardiology (ESC) and the European Cardiac Arrhythmia Society (ECAS); and in collaboration with the American College of Cardiology (ACC), American Heart Association (AHA), the Asia Pacific Heart Rhythm Society (APHRS), and the Society of Thoracic Surgeons (STS). Endorsed by the governing bodies of the American College of Cardiology Foundation, the American Heart Association, the European Cardiac Arrhythmia Society, the European Heart Rhythm Association, the Society of Thoracic Surgeons, the Asia Pacific Heart Rhythm Society, and the Heart Rhythm Society.

Authors:  Hugh Calkins; Karl Heinz Kuck; Riccardo Cappato; Josep Brugada; A John Camm; Shih-Ann Chen; Harry J G Crijns; Ralph J Damiano; D Wyn Davies; John DiMarco; James Edgerton; Kenneth Ellenbogen; Michael D Ezekowitz; David E Haines; Michel Haissaguerre; Gerhard Hindricks; Yoshito Iesaka; Warren Jackman; José Jalife; Pierre Jais; Jonathan Kalman; David Keane; Young-Hoon Kim; Paulus Kirchhof; George Klein; Hans Kottkamp; Koichiro Kumagai; Bruce D Lindsay; Moussa Mansour; Francis E Marchlinski; Patrick M McCarthy; J Lluis Mont; Fred Morady; Koonlawee Nademanee; Hiroshi Nakagawa; Andrea Natale; Stanley Nattel; Douglas L Packer; Carlo Pappone; Eric Prystowsky; Antonio Raviele; Vivek Reddy; Jeremy N Ruskin; Richard J Shemin; Hsuan-Ming Tsao; David Wilber
Journal:  Heart Rhythm       Date:  2012-03-01       Impact factor: 6.343

3.  The relationship between contact force and clinical outcome during radiofrequency catheter ablation of atrial fibrillation in the TOCCATA study.

Authors:  Vivek Y Reddy; Dipen Shah; Josef Kautzner; Boris Schmidt; Nadir Saoudi; Claudia Herrera; Pierre Jaïs; Gerhard Hindricks; Petr Peichl; Aude Yulzari; Hendrik Lambert; Petr Neuzil; Andrea Natale; Karl-Heinz Kuck
Journal:  Heart Rhythm       Date:  2012-07-20       Impact factor: 6.343

4.  The impact of CT image integration into an electroanatomic mapping system on clinical outcomes of catheter ablation of atrial fibrillation.

Authors:  Peter M Kistler; Kim Rajappan; Mohammed Jahngir; Mark J Earley; Stuart Harris; Dominic Abrams; Dhiraj Gupta; Reginald Liew; Stephen Ellis; Simon C Sporton; Richard J Schilling
Journal:  J Cardiovasc Electrophysiol       Date:  2006-10

5.  A novel radiofrequency ablation catheter using contact force sensing: Toccata study.

Authors:  Karl-Heinz Kuck; Vivek Y Reddy; Boris Schmidt; Andrea Natale; Petr Neuzil; Nadir Saoudi; Josef Kautzner; Claudia Herrera; Gerhard Hindricks; Pierre Jaïs; Hiroshi Nakagawa; Hendrik Lambert; Dipen C Shah
Journal:  Heart Rhythm       Date:  2011-08-26       Impact factor: 6.343

6.  Initial results of using a novel irrigated multielectrode mapping and ablation catheter for pulmonary vein isolation.

Authors:  Dong-In Shin; Kiriakos Kirmanoglou; Christian Eickholt; Jan Schmidt; Lukas Clasen; Britta Butzbach; Tienush Rassaf; Marc Merx; Malte Kelm; Christian Meyer
Journal:  Heart Rhythm       Date:  2013-12-07       Impact factor: 6.343

7.  Which is the best catheter to perform atrial fibrillation ablation? A comparison between standard ThermoCool, SmartTouch, and Surround Flow catheters.

Authors:  Luigi Sciarra; Paolo Golia; Andrea Natalizia; Ermenegildo De Ruvo; Serena Dottori; Antonio Scarà; Alessio Borrelli; Lucia De Luca; Marco Rebecchi; Alessandro Fagagnini; Alberto Bandini; Fabrizio Guarracini; Marcello Galvani; Leonardo Calò
Journal:  J Interv Card Electrophysiol       Date:  2014-02-21       Impact factor: 1.900

8.  The impact of image integration on catheter ablation of atrial fibrillation using electroanatomic mapping: a prospective randomized study.

Authors:  Peter M Kistler; Kim Rajappan; Stuart Harris; Mark J Earley; Laura Richmond; Simon C Sporton; Richard J Schilling
Journal:  Eur Heart J       Date:  2008-10-17       Impact factor: 29.983

Review 9.  Current hot potatoes in atrial fibrillation ablation.

Authors:  Laurent Roten; Nicolas Derval; Patrizio Pascale; Daniel Scherr; Yuki Komatsu; Ashok Shah; Khaled Ramoul; Arnaud Denis; Frédéric Sacher; Mélèze Hocini; Michel Haïssaguerre; Pierre Jaïs
Journal:  Curr Cardiol Rev       Date:  2012-11

10.  Computed tomography model-based treatment of atrial fibrillation and atrial macro-re-entrant tachycardia.

Authors:  Christopher Piorkowski; Simon Kircher; Arash Arya; Thomas Gaspar; Masahiro Esato; Sam Riahi; Andreas Bollmann; Daniela Husser; Charlotte Staab; Philipp Sommer; Gerhard Hindricks
Journal:  Europace       Date:  2008-06-23       Impact factor: 5.214

View more
  3 in total

Review 1.  Applications of Advanced Imaging in Cardiac Electrophysiology.

Authors:  Mrinal Yadava; Michael D Shapiro
Journal:  Curr Treat Options Cardiovasc Med       Date:  2016-11

2.  Atrial fibrillation ablation with a spring sensor-irrigated contact force-sensing catheter compared with other ablation catheters: systematic literature review and meta-analysis.

Authors:  Laurent Macle; Diana Frame; Larry M Gache; George Monir; Scott J Pollak; Lee Ming Boo
Journal:  BMJ Open       Date:  2019-06-11       Impact factor: 2.692

Review 3.  Applications of multimodality imaging for left atrial catheter ablation.

Authors:  Caroline H Roney; Charles Sillett; John Whitaker; Jose Alonso Solis Lemus; Iain Sim; Irum Kotadia; Mark O'Neill; Steven E Williams; Steven A Niederer
Journal:  Eur Heart J Cardiovasc Imaging       Date:  2021-12-18       Impact factor: 6.875

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.