Effects of Laboratory Disinfecting Agents on Dimensional Stability of Three Commercially Available Heat-Cured Denture Acrylic Resins in India: An In-Vitro Study.

Jayaprakash Mugur Basavanna1, Ravikanth Haridas Jujare2, Rana Kalappattil Varghese3, Vishwa Deepak Singh4, Amit Gaurav5.   

Abstract

INTRODUCTION: Dental professionals are exposed to a wide variety of microorganisms which calls for use of effective infection control procedures in the dental office and laboratories that can prevent cross-contamination that could extend to dentists, dental office staff, dental technicians as well as patients. This concern has led to a renewed interest in denture sterilization and disinfection. Heat polymerized dentures exhibit dimensional change during disinfection procedure. AIM: The purpose of this study was to determine the influence of different types of widely used laboratory disinfecting agents on the dimensional stability of heat-cured denture acrylic resins and to compare the dimensional stability of three commercially available heat-cured denture acrylic resins in India.
MATERIALS AND METHODS: Twelve specimens of uniform dimension each of three different brands namely Stellon, Trevalon and Acralyn-H were prepared using circular metal disc. Chemical disinfectants namely 2% alkaline glutaraldehyde, 1% povidone-iodine, 0.5% sodium hypochlorite and water as control group were used. Diameter of each specimen was measured before immersion and after immersion with time interval of 1 hour and 12 hours. The data was evaluated statistically using one way analysis of variance.
RESULTS: All the specimens in three disinfectants and in water exhibited very small amount of linear expansion. Among three disinfectants, specimens in 2% alkaline glutaraldehyde exhibited least(0.005mm) and water showed highest (0.009mm) amount of dimensional change. Among resins, Trevalon showed least (0.067mm) and Acralyn-H exhibited highest (0.110mm) amount of dimensional change.
CONCLUSION: Although, all the specimens of three different brands of heat-cured denture acrylic resins exhibited increase in linear dimensional change in all the disinfectants and water, they were found to be statistically insignificant.

Entities:  

Keywords:  Acrylic resin denture; Chemical disinfectants; Cross-contamination; Disinfection; Stability

Year:  2016        PMID: 27134996      PMCID: PMC4843381          DOI: 10.7860/JCDR/2016/17542.7403

Source DB:  PubMed          Journal:  J Clin Diagn Res        ISSN: 0973-709X


  14 in total

1.  Dimensional accuracy and stability of acrylic resin denture bases.

Authors:  R Huggett; A Zissis; A Harrison; A Dennis
Journal:  J Prosthet Dent       Date:  1992-10       Impact factor: 3.426

2.  The effect of disinfection procedures on flexural properties of denture base acrylic resins.

Authors:  T Asad; A C Watkinson; R Huggett
Journal:  J Prosthet Dent       Date:  1992-07       Impact factor: 3.426

3.  Effect of microwave treatments on dimensional accuracy of maxillary acrylic resin denture base.

Authors:  Sabrina Pavan; João Neudenir Arioli Filho; Paulo Henrique Dos Santos; Francisco de Assis Mollo
Journal:  Braz Dent J       Date:  2005

4.  Effects of laboratory disinfecting agents on color stability of denture acrylic resins.

Authors:  S J McNeme; A S von Gonten; G D Woolsey
Journal:  J Prosthet Dent       Date:  1991-07       Impact factor: 3.426

5.  Dimensional stability of occlusal splints.

Authors:  D M Bohnenkamp
Journal:  J Prosthet Dent       Date:  1996-03       Impact factor: 3.426

6.  Infection control recommendations for the dental office and the dental laboratory. ADA Council on Scientific Affairs and ADA Council on Dental Practice.

Authors: 
Journal:  J Am Dent Assoc       Date:  1996-05       Impact factor: 3.634

7.  Color changes of denture base materials after disinfection and sterilization immersion.

Authors:  G L Polyzois; S A Yannikakis; A J Zissis; P P Demetriou
Journal:  Int J Prosthodont       Date:  1997 Jan-Feb       Impact factor: 1.681

8.  The effect of glutaraldehyde base disinfectants on denture base resins.

Authors:  C Shen; N S Javid; F A Colaizzi
Journal:  J Prosthet Dent       Date:  1989-05       Impact factor: 3.426

9.  The effect of repeated microwave irradiation on the dimensional stability of a specific acrylic denture resin.

Authors:  David A Wagner; Donald J Pipko
Journal:  J Prosthodont       Date:  2014-07-31       Impact factor: 2.752

10.  Microwave disinfection of complete dentures contaminated in vitro with selected bacteria.

Authors:  Lívia Nordi Dovigo; Ana Cláudia Pavarina; Daniela Garcia Ribeiro; Juliana Aparecida de Oliveira; Carlos Eduardo Vergani; Ana Lucia Machado
Journal:  J Prosthodont       Date:  2009-06-11       Impact factor: 2.752

View more
  2 in total

1.  Effect of Disinfectants on Mechanical Properties of Orthodontic Acrylics.

Authors:  Tobias Bensel; Jens J Bock; Anne Kebernik; Christin Arnold; Sonia Mansour; Arne F Boeckler
Journal:  Int J Biomater       Date:  2019-04-24

2.  Composition's effect of Origanum Syriacum essential oils in the antimicrobial activities for the treatment of denture stomatitis.

Authors:  Loubna Shamseddine; Jose Johann Chidiac
Journal:  Odontology       Date:  2020-08-17       Impact factor: 2.634

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.