Literature DB >> 8648572

Dimensional stability of occlusal splints.

D M Bohnenkamp1.   

Abstract

Five fabrication techniques and two storage methods were used to construct and store specimens to investigate the dimensional stability of acrylic resin occlusal splints. A research model was developed to more closely approximate the tooth coverage limits of occlusal splints. Ten specimens were fabricated on individual stone casts for each of the five techniques. Four die pins were transferred to each specimen, and the distances between the inside diameters of the pins were measured over a 2-week period. After construction, initial measurement, and removal from the cast, each acrylic resin specimen was stored in either a wet or a dry environment. Measurements between pins were made and recorded at five time intervals. The sprinkle-on techniques resulted in less dimensional change than the dough application, the vacuum-adapted resin sheet and dough application, and the heat-cured denture processing techniques. Acrylic resin specimens stored in a wet environment showed less distortion 2 weeks after fabrication.

Mesh:

Substances:

Year:  1996        PMID: 8648572     DOI: 10.1016/s0022-3913(96)90482-5

Source DB:  PubMed          Journal:  J Prosthet Dent        ISSN: 0022-3913            Impact factor:   3.426


  5 in total

1.  Effects of Laboratory Disinfecting Agents on Dimensional Stability of Three Commercially Available Heat-Cured Denture Acrylic Resins in India: An In-Vitro Study.

Authors:  Jayaprakash Mugur Basavanna; Ravikanth Haridas Jujare; Rana Kalappattil Varghese; Vishwa Deepak Singh; Amit Gaurav
Journal:  J Clin Diagn Res       Date:  2016-03-01

2.  Effect of occlusal coverage depths on the precision of 3D-printed orthognathic surgical splints.

Authors:  Yipeng Wang; Peiqi Wang; Xiang Xiang; Hui Xu; Yuting Tang; Yumeng Zhou; Ding Bai; Chaoran Xue
Journal:  BMC Oral Health       Date:  2022-06-02       Impact factor: 3.747

3.  Accuracy of CAD/CAM-fabricated bite splints: milling vs 3D printing.

Authors:  Reymus Marcel; Hickel Reinhard; Keßler Andreas
Journal:  Clin Oral Investig       Date:  2020-05-21       Impact factor: 3.573

4.  Two-body wear of occlusal splint materials from subtractive computer-aided manufacturing and three-dimensional printing.

Authors:  Felix Schmeiser; Uwe Baumert; Bogna Stawarczyk
Journal:  Clin Oral Investig       Date:  2022-05-25       Impact factor: 3.606

5.  Effects of storage and toothbrush simulation on color, gloss, and roughness of CAD/CAM, hand-cast, thermoforming, and 3D-printed splint materials.

Authors:  Verena Hickl; Thomas Strasser; Alois Schmid; Martin Rosentritt
Journal:  Clin Oral Investig       Date:  2022-02-04       Impact factor: 3.606

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.