Literature DB >> 1941663

Effects of laboratory disinfecting agents on color stability of denture acrylic resins.

S J McNeme, A S von Gonten, G D Woolsey.   

Abstract

This study determined the effects of chemical disinfecting agents on denture acrylic resins. Tested resins included the products CH Lucitone, Triad VLC, and Truliner. The disinfecting agents were sodium hypochlorite, Exspor, Cidex, and Wescodyne-D. Acrylic resin samples were placed in the various disinfecting agents and then evaluated for color changes at time intervals ranging from 15 minutes to 72 hours. No observable color change of any acrylic resin was seen before 2 hours. Both 1% sodium hypochlorite and 2% Cidex disinfectants produced the least discoloration of the acrylic resins, and Wescodyne-D disinfectant produced the most acrylic resin discoloration. Truliner resin discolored more than Triad VLC resin, and both underwent more color change than CH Lucitone resin. If manufacturers' recommended disinfecting times are followed, clinical and laboratory disinfection of acrylic resin dentures should cause no observable color change.

Entities:  

Mesh:

Substances:

Year:  1991        PMID: 1941663     DOI: 10.1016/0022-3913(91)90359-5

Source DB:  PubMed          Journal:  J Prosthet Dent        ISSN: 0022-3913            Impact factor:   3.426


  6 in total

1.  Disinfecting the acrylic resin plate using electrolyzed acid water and 2% glutaraldehyde: a comparative microbiological study.

Authors:  K R Jnanadev; C L Satish Babu; S Shilpa Shetty; G P Surendra Kumar; H S Sheetal
Journal:  J Indian Prosthodont Soc       Date:  2011-04-07

2.  Color stability of denture teeth and acrylic base resin subjected daily to various consumer cleansers.

Authors:  Audrey Moon; John M Powers; Sudarat Kiat-Amnuay
Journal:  J Esthet Restor Dent       Date:  2014-06-30       Impact factor: 2.843

3.  Effect of 5.25 % sodium hypochlorite on color stability of acrylic and silicone based soft liners and a denture base acrylic resin.

Authors:  Alaa'a M Salloum
Journal:  J Indian Prosthodont Soc       Date:  2013-08-10

4.  Effects of Laboratory Disinfecting Agents on Dimensional Stability of Three Commercially Available Heat-Cured Denture Acrylic Resins in India: An In-Vitro Study.

Authors:  Jayaprakash Mugur Basavanna; Ravikanth Haridas Jujare; Rana Kalappattil Varghese; Vishwa Deepak Singh; Amit Gaurav
Journal:  J Clin Diagn Res       Date:  2016-03-01

5.  Effects of fluconazole, chlorhexidine gluconate, and silver-zinc zeolite on flexural strength of heat-cured polymethyl methacrylate resin.

Authors:  Naveen S Yadav; Sneha Saraf; Sunil Kumar Mishra; Puja Hazari
Journal:  J Nat Sci Biol Med       Date:  2015 Jul-Dec

6.  Effect of repeated immersion solution cycles on the color stability of denture tooth acrylic resins.

Authors:  Paulo Maurício Batista da Silva; Emílio José Tabaré Rodríguez Acosta; Matheus Jacobina; Luciana de Rezende Pinto; Vinícius Carvalho Porto
Journal:  J Appl Oral Sci       Date:  2011 Nov-Dec       Impact factor: 2.698

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.