Literature DB >> 25082075

The effect of repeated microwave irradiation on the dimensional stability of a specific acrylic denture resin.

David A Wagner1, Donald J Pipko.   

Abstract

PURPOSE: To determine the dimensional stability of a poly(methyl methacrylate) (PMMA) acrylic resin when subjected to multiple sessions of repeated microwave irradiation at power settings of 700 and 420 W.
MATERIALS AND METHODS: Twenty standardized denture bases were fabricated using a PMMA resin. Points of measurement were marked on each denture base with a standardized template, and the distances between points were recorded using a digital microscope. The denture bases were randomly placed into two experimental groups of 10 bases each. Individual denture bases were placed into a glass beaker containing 200 ml of room temperature deionized water and then exposed to either 700 or 420 W of microwave radiation for 3 minutes. The denture bases were allowed to cool to room temperature, and measurements between points were recorded. This process was carried out for two microwave periods with measurements being completed after each period. The data were then analyzed for any significant changes in distances between points using a Student's t-test.
RESULTS: All denture bases experienced 1.0 to 2.0 mm or approximately 3% linear dimensional change after each period of microwaving. Results were significant with all t-tests having values of p < 0.05.
CONCLUSION: This report showed that the denture bases deformed significantly under experimental conditions at either 700 W for 3 minutes in 200 ml of water or 420 W for 3 minutes in 200 ml of water.
© 2014 by the American College of Prosthodontists.

Entities:  

Keywords:  Heating; complete; dental; prosthesis; warpage

Mesh:

Substances:

Year:  2014        PMID: 25082075     DOI: 10.1111/jopr.12203

Source DB:  PubMed          Journal:  J Prosthodont        ISSN: 1059-941X            Impact factor:   2.752


  5 in total

1.  Effects of Laboratory Disinfecting Agents on Dimensional Stability of Three Commercially Available Heat-Cured Denture Acrylic Resins in India: An In-Vitro Study.

Authors:  Jayaprakash Mugur Basavanna; Ravikanth Haridas Jujare; Rana Kalappattil Varghese; Vishwa Deepak Singh; Amit Gaurav
Journal:  J Clin Diagn Res       Date:  2016-03-01

Review 2.  The Effect of Microwave Disinfection on Denture Base Polymers, Liners and Teeth: A Basic Overview.

Authors:  Theodoros Klironomos; Aspasia Katsimpali; Gregory Polyzois
Journal:  Acta Stomatol Croat       Date:  2015-09

3.  The Effect of Repeated Microwaving Disinfection on the Dimensional Stability of Acrylic Dentures.

Authors:  Nick Polychronakis; Stavros Yannikakis; Alcibiades Zissis
Journal:  Acta Stomatol Croat       Date:  2014-12

4.  Long-term microwaving of denture base materials: effects on dimensional, color and translucency stability.

Authors:  Nick Polychronakis; Gregory Polyzois; Panagiotis Lagouvardos; Andreas Andreopoulos; Hien Chi Ngo
Journal:  J Appl Oral Sci       Date:  2018-06-18       Impact factor: 2.698

Review 5.  Biological and Chemo-Physical Features of Denture Resins.

Authors:  Gabriele Cervino; Marco Cicciù; Alan Scott Herford; Antonino Germanà; Luca Fiorillo
Journal:  Materials (Basel)       Date:  2020-07-28       Impact factor: 3.623

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.