Literature DB >> 16475605

Effect of microwave treatments on dimensional accuracy of maxillary acrylic resin denture base.

Sabrina Pavan1, João Neudenir Arioli Filho, Paulo Henrique Dos Santos, Francisco de Assis Mollo.   

Abstract

Microwave energy has been used as an alternative method for disinfection and sterilization of dental prostheses. This study evaluated the influence of microwave treatment on dimensional accuracy along the posterior palatal border of maxillary acrylic resin denture bases processed by water-bath curing. Thirty maxillary acrylic bases (3-mm-thick) were made on cast models with Clássico acrylic resin using routine technique. After polymerization and cooling, the sets were deflasked and the bases were stored in water for 30 days. Thereafter, the specimens were assigned to 3 groups (n=10), as follows: group I (control) was not submitted to any disinfection cycle; group II was submitted to microwave disinfection for 3 min at 500 W; and in group III microwaving was done for 10 min at 604 W. The acrylic bases were fixed on their respective casts with instant adhesive (Super Bonder) and the base/cast sets were sectioned transversally in the posterior palatal zone. The existence of gaps between the casts and acrylic bases was assessed using a profile projector at 5 points. No statistically significant differences were observed between the control group and group II. However, group III differed statistically from the others (p<0.05). Treatment in microwave oven at 604 W for 10 min produced the greatest discrepancies in the adaptation of maxillary acrylic resin denture bases to the stone casts.

Entities:  

Mesh:

Substances:

Year:  2005        PMID: 16475605     DOI: 10.1590/s0103-64402005000200006

Source DB:  PubMed          Journal:  Braz Dent J        ISSN: 0103-6440


  12 in total

1.  Effect of simulated microwave disinfection on the mechanical properties of three different types of denture base resins.

Authors:  Jagadish Konchada; Suma Karthigeyan; Syed Asharaf Ali; Venkateshwaran R; Ramesh Amirisetty; Anurag Dani
Journal:  J Clin Diagn Res       Date:  2013-12-15

2.  Effects of Laboratory Disinfecting Agents on Dimensional Stability of Three Commercially Available Heat-Cured Denture Acrylic Resins in India: An In-Vitro Study.

Authors:  Jayaprakash Mugur Basavanna; Ravikanth Haridas Jujare; Rana Kalappattil Varghese; Vishwa Deepak Singh; Amit Gaurav
Journal:  J Clin Diagn Res       Date:  2016-03-01

Review 3.  The Effect of Microwave Disinfection on Denture Base Polymers, Liners and Teeth: A Basic Overview.

Authors:  Theodoros Klironomos; Aspasia Katsimpali; Gregory Polyzois
Journal:  Acta Stomatol Croat       Date:  2015-09

4.  The Effect of Repeated Microwaving Disinfection on the Dimensional Stability of Acrylic Dentures.

Authors:  Nick Polychronakis; Stavros Yannikakis; Alcibiades Zissis
Journal:  Acta Stomatol Croat       Date:  2014-12

5.  Effectiveness of Chemical and Microwave Disinfection on Denture Biofilm Fungi and the Influence of Disinfection on Denture Base Adaptation.

Authors:  Mohannad H Al-Saadi
Journal:  J Indian Prosthodont Soc       Date:  2014-02-07

6.  Cumulative effect of microwave sterilization on the physical properties of microwave polymerized and conventional heat-polymerized acrylic resin.

Authors:  S Mohammed Shafeeq; S Karthikeyan; Subash M Reddy; Suma Karthigeyan; R Manikandan; Arthiie Thangavelu
Journal:  J Pharm Bioallied Sci       Date:  2016-10

7.  Comparative evaluation of sodium hypochlorite and microwave disinfection on dimensional stability of denture bases.

Authors:  Rutuja Madhukarrao Nirale; Ram Thombre; Girish Kubasad
Journal:  J Adv Prosthodont       Date:  2012-02-29       Impact factor: 1.904

8.  Effect of repeated simulated disinfections by microwave energy on the complete denture base adaptation.

Authors:  Rafael L X Consani; Rose Y Iwasaki; Marcelo F Mesquita; Wilson B Mendes; Simonides Consani
Journal:  Open Dent J       Date:  2008-04-29

9.  Effect of the simulated disinfection by microwave energy on the impact strength of the tooth/acrylic resin adhesion.

Authors:  Rafael L X Consani; Marcelo F Mesquita; Marinaldo H Zampieri; Wilson B Mendes; Simonides Consani
Journal:  Open Dent J       Date:  2008-01-22

10.  Effect of flask closure method and post-pressing time on the displacement of maxillary denture teeth.

Authors:  Wagner A Negreiros; Rafael L X Consani; Marcelo F Mesquita; Mario A C Sinhoreti; Ivan R Faria
Journal:  Open Dent J       Date:  2009-03-06
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.